Bincika MCL3066 Cikakkiyar ID/Tsarin AST. Sami saurin ƙimar MIC GASKIYA, ƙarfin katin 60, da ingantacciyar ganewar ƙwayoyin cuta don labs na asibiti.
| samuwa: | |
|---|---|
| Yawan: | |
Saukewa: MCL3066
MAI KYAU
MCL3066 Cikakken ID/Tsarin AST an tsara shi don dakunan gwaje-gwajen ƙwayoyin cuta na asibiti. Yana yin ta atomatik gano nau'in ƙwayoyin cuta (ID) da gwajin kamuwa da ƙwayoyin cuta (AST) . Wannan yana ba da sauri, ingantattun sakamako don haɓaka aikin kula da ƙwayoyin cuta da sakamakon haƙuri.
l Colorimetry don Ganewa: Tsarin yana amfani da ka'idodin launi don gano ƙwayar cuta ta ƙwayoyin cuta ta hanyar kwatancen gwajin ƙwayoyin cuta na musamman. Ana kwatanta tsarin ɗaukar hoto na gani tare da bayanan ƙananan ƙwayoyin cuta don gano iri.
l Turbidimetry don Gwajin Cutarwa: Tsarin yana amfani da turbidimetry na gani don gwajin ji na ƙwayoyin cuta. Yana auna sauye-sauyen girma a matakan ƙwayoyin cuta daban-daban don ƙayyade mafi ƙarancin Inhibitory Concentration (MIC) . ƙima
1. Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwaƙwalwa na Ƙaddamarwa: Na farko, ware yankuna daga kafofin watsa labarai na al'ada na farko. Na gaba, dakatar da su a daidaitaccen saline. A ƙarshe, daidaita girman inoculum tare da turbidimeter McFarland.
2. Samfurori Na atomatik & Loading Panel: Load da dakatarwar kwayan cuta da katin gwaji a cikin tsarin. Na gaba, masu ba da wutar lantarki ta atomatik suna cika kowane gwaji da kyau da ainihin madaidaicin.
3. Ƙaddamarwa ta atomatik, Karatu & Samar da Rahoto: Kayan aikin yana ƙaddamar da katunan gwaji ta atomatik. A lokaci guda, yana bin diddigin yawan gani da canje-canjen launi. Algorithms na ci gaba sannan aiwatar da waɗannan sigina don fitar da ingantaccen rahoton ID/AST.
Labs na asibiti a Afirka da kudu maso gabashin Asiya suna fuskantar manyan matsaloli guda uku:
l Jinkirin bincike na hannu yana dakatar da kulawa da sauri.
l Haɗarin kamuwa da cuta yana cutar da aminci.
l ƙwaƙƙwaran ƙwayoyin ƙwayoyin cuta fiye da kima na haɓaka juriya na ƙwayoyi.
The MCL3066 Automated Microbial Analysis System solves these operational pain points directly.
Tsarin yana ba da madaidaicin Matsakaicin Inhibitory Concentration (MIC) ta amfani da matakan dilution 9. Yana maye gurbin ƙididdiga marasa ƙarfi da ingantattun bayanai. A sakamakon haka, likitocin suna samun daidaitaccen jagorar sashi don inganta kulawar haƙuri.
Tsarin yana gano alamun juriya ta atomatik don jagorantar jiyya cikin sauri:
l MRSA (Methicillin-Resistant Staphylococcus aureus).
l VRE (Vancomycin-Resistant Enterococcus).
l ESBLs (Extended-Spectrum Beta-Lactamases).
l Carbapenemases.
Tsarin yana maye gurbin gwaje-gwajen bututun sinadarai na hannu tare da tafiyar aiki mai sarrafa kansa. Yana sarrafa kowane mataki daga samfurin shiryawa zuwa rahoton aikawa.
Katunan amsawa da ke tattare da samfura ta atomatik suna kiyaye ma'aikatan lab lafiya. Wannan ƙira mai wayo yana rage bayyanar da ma'aikaci kai tsaye zuwa haɗarin ƙwayoyin cuta.
Haɗe-haɗe fashe masu haɗaka suna haɗa ID da AST akan kati ɗaya. Wannan ƙira yana rage yawan amfani da reagent kuma yana rage farashin kowane gwaji.
Tsarin yana goyan bayan gano ƙwayoyin cuta na yau da kullun da gwajin ji na ƙwayoyin cuta. Yana sarrafa samfuran al'adu daban-daban, gami da jini, fitsari, sputum, da swabs rauni. Sakamakon haka, dakunan gwaje-gwaje a gabaɗaya unguwanni da ICUs suna samun sauri, amintaccen bayanan bincike.
Tsarin yana tallafawa mahimmancin sa ido kan lafiyar jama'a a yankinku:
l Sa ido kan juriya na miyagun ƙwayoyi na yanki don bin hanyoyin jiyya
l Binciken cututtukan cututtuka don nazarin yaduwar cututtuka
l Binciken fashewar kamuwa da cuta don dakatar da cutar da sauri
Tsarin yana ba da saurin gano ƙananan ƙwayoyin cuta da gwajin gurɓatawa a cikin wurare.It yana hidimar dakunan tsabta na magunguna, tsire-tsire masu sarrafa abinci, da ɗakunan gwaje-gwaje masu sarrafa inganci.
Tsarin yana aiki azaman dandamalin gwaji iri-iri a cikin saitunan ilimi:
l Bincike na ilimi don ƙananan karatun asibiti
l Gano nau'ikan ƙwayoyin cuta don manyan labs
l Dakunan gwaje-gwaje na koyarwa don horar da ɗaliban likitanci
Siga |
Ƙayyadaddun Bayani |
Samfurin Samfura |
Saukewa: MCL3066 |
Hanyar Ganewa |
Launi (ID) & Turbidimetry (AST) |
Iyawa |
60 kati |
Lokacin Rahoto |
Har zuwa 8 hours |
Cikakken nauyi |
135kg |
Girman kayan aiki |
880mm*635*878mm |
Kunshin S ize |
945mm*700*1080mm |
Ƙarfi |
AC100-240V, 50/60Hz, 1100VA |
Bukatun Muhalli |
l Yanayin Yanayin Aiki: 5°C zuwa 30°C l Tsawon Lantarki mai Aiki: <80% zafi mai dangi, mara taurin kai |
Wannan ƙaƙƙarfan rukunin yana haɗa incubator, mai karatu, tsarin ƙwararru, mai nazari, da ginanniyar mai karanta lambar lamba. Yana goyan bayan ingantaccen gwaji mai sarrafa kansa da bin diddigin samfurin mara kuskure a cikin ayyukan yau da kullun.
Wannan tsarin yana sadar da madaidaicin TRUE MIC V alues da daidaitattun fassarori dangane da sabbin ƙa'idodin CLSI M100. Yana fasalta zaɓaɓɓun rahoto da ba da rahoto a cikin ƙungiyoyin A, B, C, da U. Waɗannan rahotanni masu sarrafa kansu suna goyan bayan shirye-shiryen kula da ƙwayoyin cuta da haɓaka ingantaccen amfani da ƙwayoyin cuta.
Tsarin ya haɗa da sabunta bayanai dangane da sabbin jagororin CLSI da EUCAST . Yana goyan bayan haɗin LIS da fitarwa na WHONET . Waɗannan fasalulluka suna ba da damar bayar da rahoton annoba marasa ƙarfi da ingantaccen sarrafa bayanan asibiti.
Wannan tsarin yana ɗaukar katunan har zuwa 60 a kowace gudu don gwaji mai girma. Yana ba da mafi ƙarancin lokutan rahoton da sauri kamar sa'o'i 8 . Waɗannan lokutan saurin juyowa suna ba da damar yanke shawara na asibiti da sauri, ingantaccen bayani.
Yana da fa'ida mai fa'ida, mai sauƙin fahimta mai sarrafa harshe da yawa wanda aka haɗa tare da ginanniyar ayyukan ƙididdiga don nazarin bayanai da yawa da kuma rahoton dakin gwaje-gwaje.
MECANMED shine babban mai ba da kayan aikin likita tasha ɗaya. Muna ba da ingantaccen kayan aikin bincike don masu ba da lafiya da masu rarrabawa a duk duniya.
Yana ba da gwajin gwaji ta atomatik akan kayan aiki mai sauƙi da farashi mai amfani. Ya yi daidai da kasafin kuɗin jama'a da masu ba da kiwon lafiya masu zaman kansu.
Amintattun sarƙoƙin samar da kayayyaki suna taimakawa adana katunan gwaji da reagents a hannun jari.
Yana ba da goyon bayan fasaha, horar da ma'aikata, da sabis na tallace-tallace.
Yana ba da mafita na dakin gwaje-gwaje na IVD tasha ɗaya. Waɗannan na iya haɗawa da:
l Tsarin al'adun jini
l Majalisar lafiyar halittu
l Autoclave
l Centrifuge
Tsarin MCL3066 yana amfani da katunan gwaji na musamman da abubuwan da ake amfani da su na rigakafi. Yana gano ƙwayoyin cuta, yisti, da juriya na antimicrobial.
An taƙaita takamaiman ayyuka da aikace-aikacen asibiti na kowane nau'in katin gwaji a ƙasa:
Katin Gwaji / Nau'in Amfani |
Aiki & Aikace-aikacen asibiti |
Gram-Negative ID/Katin AST |
Ana amfani da shi don ganowa da gwajin cutarwa na Gram-negative bacilli (Enterobacteriaceae da wadanda ba fermenters). |
Gram-Positive ID/Katin AST |
An yi amfani da shi don ganowa da gwajin cutarwa na Gram-positive cocci ( Staphylococcus, Streptococcus, Enterococcus ). |
Katin ID Yisti / Fungus |
Yana ba da ganewar biochemical don yisti na kowa na asibiti da nau'in fungal. |
Standard Inoculation Reagents |
Maganin Saline da kayan aikin daidaita turbidity don daidaitaccen shiri na dakatar da samfurin. |
MECANMED yana ba da goyon bayan fasaha da aiki don masu siye da abokan ciniki na duniya. Muna ba da littattafan mai amfani, bidiyo masu aiki, da taimakon fasaha na nesa. Ta hanyar hanyar sadarwar tallafi ta yanki, muna kuma samar da shigarwa da kuma kula da injiniyoyi a cikin zaɓaɓɓun yankuna na Afirka da Philippines.
Tsarin MCL3066 yana goyan bayan kewayon shigar wutar lantarki mai faɗi (AC 100V-240V) don samar da wutar lantarki daban-daban na yanki. A cikin wuraren da ke da yawan canjin wutar lantarki ko katsewar wutar lantarki, ana ba da shawarar samar da wutar lantarki ta kan layi (UPS) . Yana taimakawa kula da hawan keke da rage haɗarin asarar bayanai yayin gwaji.
Shirya don haɓaka dakin gwaje-gwajen microbiology na asibiti? Zaɓi MCL3066 Cikakken Tsarin ID na Microbial/AST don ingantaccen gwajin ID/AST mai sarrafa kansa , bayar da rahoto cikin sauri, da tallafin kula da ƙwayoyin cuta.
Tuntuɓi ƙungiyarmu a yau don gasa farashin farashi da mafita na dakin gwaje-gwajen tasha ɗaya.