MCM-9000 12.1 inch Patient Monitor with capnography
MCM-9000 12.1 inch Patient Monitor with capnography
MCM-9000 12.1 inch Patient Monitor with capnography
MCM-9000 12.1 inch Patient Monitor with capnography
MCM-9000 12.1 inch Patient Monitor with capnography

MCM-9000 12.1 inch Patient Monitor with capnography

Model NO.:
MCM-9000
Price:
USD 100.00-10000.00 / set
Delivery:
FOB
Minimum order quantity:
1 set
Supply Ability:
1000 set / Month
Country of Origin:
Guangzhou, Shenzhen, Beijing, Shanghai, Hongkong
Stock Time:
5~15 working days for the MCM-9000 12.1 inch Patie Days
  • Place of Origin:CN;GUA
  • Model Number:MCM-9000
  • Brand Name:MeCan
  • Type:Maternal-Neonatal Ultrasonic Monitor
  • Instrument classification:Class II

12.1 inch Patient Monitor with capnography 

Model: MCM-9000 

  patient monitor OSEN9000-with CO2 .jpg patient monitor OSEN9000-side (1).jpg

Features of the MCM-9000 12.1 inch Patient Monitor with capnography:

 

12.1"color TFT screen

Multi-channel display

Big font interface

ST and arrhythmia analysis

Drug dose calculation and titration table

OxyCRG dynamic view display

wi Respiration monitoring th apnea alarms

 

Alarm review, arrhythmia review

Patient info. Input

Anti-defibrillation design

NIBP over pressure protection

Plug-in rechargeable battery, AC/DC available.

Supporting wire or wireless network.

 

Technical Specifications of the MCM-9000 12.1 inch Patient Monitor with capnography:

 

ECG

 

Lead Mode                            5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection                       I, II, III, avR, avL, avF, V

Wavef orm                             2 ch

Lead mode                            3 Leads ( R, L, F or RA, LA, LL)

Lead selection                        I, II, III,

Wave form                              1 ch

Gain                                        2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

 

HR and Alarm Range                      Adult    15 ~ 300 bpm

                                                       Neo/Ped    15 ~ 350 bpm

Accuracy                                        ±1% or±1bpm, which is greater

Resolution                                     1 bpm

Sensitivity                                      > 200 (uVp-p)

Differential Input Impedance         > 5 MΩ

 

CMRR                                   Monitor > 105 dB

                                             Operation > 105 dB

                                              Diagnosis > 85 dB

 

Electrode offset potential           ±300mV

Leakage Current                       < 10 uA

Baseline Recovery                    < 3 S After Defi.

ECG Signal Range                    ±8 m V ( Vp-p )

 

Bandwidth                                         Surgery    1 ~ 20 Hz

                                                          Monitor     0.5 ~ 40 Hz

                                                          Diagnostic  0.05 ~ 130 Hz

Calibration Signal                              1 (mVp-p),  Accuracy:5%

ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting                                   Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP, PNC,Alarm Available,Review Available

 

Respirationof the MCM-9000 12.1 inch Patient Monitor with capnography:

 

Method                                           Impedance between R-F(RA-LL)

Differential Input Impedance          > 2.5 MΩ

Measuring Impedance Range        0.3~3 Ω

Base line Impedance Range         200~4 KΩ

Bandwidth                                     0.1~2.5Hz

Resp. Rate                                    Measuring and Alarm Range

                                                      Adult 0 ~ 120 Brpm

                                                      Neo/Ped 0 ~ 150 Brpm

                                                      Resolution 1 Brpm

                                                      Accuracy ±2 Brpm

Apnea Alarm                                 10 ~ 40 S

 

NIBP

 

Method                              Oscillometric

Mode                                 Manual, Auto, STAT                       

Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode     5 Min

Pulse Rate Range                           40 ~ 240 bpm

Alarm Type                                      SYS, DIA, MEAN

 

Measuring and alarm range      Adult Mode

                                    SYS 40 ~ 270 mmHg       DIA 10 ~ 215 mmHg         MEAN 20 ~ 235 mmHg

                                                  Pediatric Mode

                                    SYS 40 ~ 200 mmHg        DIA 10 ~ 150 mmHg        MEAN 20 ~ 165 mmHg

                                                  Neonatal Mode

                                    SYS 40 ~ 135 mmHg        DIA 10 ~ 100 mmHg        MEAN 20 ~ 110 mmHg

Resolution                      1mmHg

Accuracy                        Maximum Mean error ±5mmHg

                                 Maximum Standard deviation ±8mmHg

Overpressure Protection          Adult Mode 297±3 mmHg

                                 Pediatric Mode 240±3 mmHg

                                 Neonatal Mode 147±3 mmHg

 

SpO2

Measuring Range                  0 ~ 100 %

Alarm Range                          0 ~ 100 %

Resolution                             1 %

Accuracy                                70% ~ 100%  2 %

                                               0%  ~  69% unspecified

Actualization intervalabout     1 Sec.

Alarm Delay                            10 Sec.

Pulse Rate                               Measuring and Alarm Range 20~300 bpm

                                                Resolution       1bpm

                                                Accuracy ±3bpm

 

TEMP

 

Channel                                         2

Measuring and Alarm Range        0 ~ 50 ℃

Resolution                                     0.1 ℃

Accuracy                                       ±0.2 ℃

Actualization intervalabout            1 Sec.

Average Time Constant                 < 10 Sec.

 

IBP

 

Label                                           ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range       ART 0 ~ 300 mmHg

                                                   PA -6 ~ 120 mmHg

                                                   CVP/RAP/LAP/ICP-10 ~ 40 mmHg

                                                   P1 / P2-10 ~ 300 mmHg

Press Sensor                              Sensitivity 5  uV/V/mmHg

                                                    Impedance 300-3000Ω

Resolution                                   1 mmHg

Accuracy                                     ±2% or 1mmHg which is greater

Actualization interval                   about 1 secretary

 

Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder

 

Monitors

We provide different kinds of Defibrillator & Monitor. Some are shown in the following pictures. For more infomation, please refer to our webside: guangzhou-medical.en.alibaba.com.

.jpg

 

 

Our Advantage

1. One stop supplier for medical equipments and laboratory equipments in Guangzhou
2. More than 2000 hospitals have become our partners
3. Superior quality with factory price
4. Quick reply and considerate service
5. CE,ISO,FDA Certificate
6. Fast delivery by air, sea or in other ways
7. More than 10 years in medical machines supply business
8. Exported to more than 109 countries
9. Warranty time: AT LEAST 12 months and Over 8 years' technical and accessories-change support
10.Excellent and immediate after-sale service

 

Together with client

We have sold 50mA Mobile X-ray Machine MCX-L102 and other medical equipment to more than 109 countries and built long term partnerships with clients such as UK, US, Italy, South Africa, Nigeria, Ghana, Kenya, Turkey, Greece, Philippines, etc

 

 

7 

Why choose us ?

2018-5-29.jpg 

How to contact us ?
Click5.jpg to contact us now !!!

 

3.jpg

Testimonials

1. From the Biomedical Engineer of Senegal.

hello, the installation of the RX unit was a success. all is ok and i have a very good picture.

 THANK YOU

 

2. From Dr. Salman Hasan, Doctor from Nigeria

Hello we have installed the radio and we are really satisfied with its operation.

 

3. From Dr. Emma Adapoe, Ghana, Africa.

 Mecan Medical Company Limited:

I have tried them for their honesty

I have tested their products for Good Quality

I have experienced their Good and and nice service and customer relations

I endorse Mecan because they stand the test of time.

 

Please contact us and let’s talk details for the MCM-9000 12.1 inch Patient Monitor with capnography 

 

 

 photobank