I-MeCan yezoNyango yobuGcisa be-Ophthalmic Eye Auto Non Contact Abavelisi beTonometer , i-OEM / ODM, elungiselelwe ngokweemfuno zakho, sikuyo ngaphezu kweminyaka eyi-15, sinobuchwephesha kwaye siya kubonelela ngeyona nkonzo ilungileyo kuwe.
Ubuninzi: | |
---|---|
Uhlobo:Izixhobo zeOphthalmic Optical
Indawo yeMvelaphi:CN;GUA
Ukuhlelwa kwesixhobo: Udidi II
Igama leBrand: Mecan
Inombolo yomzekelo: MCE-NCT10
Umzekelo: MCE-NCT10
I-tonometer ye-auto isebenzisa ulawulo lomfanekiso kunye nokuqondwa kweempawu ze-3-D ezizenzekelayo zokubeka indawo ye-xyz ngomgwebo othembekileyo kunye neziphumo zomlinganiselo, kwaye kulula ukuyisebenzisa.Indlela yokunxibelelana yomoya yokulinganisa i-IOP inokusetyenziselwa ukutyeba kwecorneal.
1.Ukuma kwe-3-D okuzenzekelayo kwexyz kubangela umlinganiselo ochanekileyo nothembekileyo
I-2.I-auto-auto measurement yedatha yeso lasekunene nasekhohlo ngaphandle kokutshintsha ngesandla
3.Kulula ukusebenzisa i-tonometer ngombala wokujonga umbala
I-4.Idatha ezinzileyo ye-IOP ngokulinganisa umoya othambileyo
5.Ukubuyisela umlinganiselo we-corneal ubukhulu be-IOP
Uluhlu lokulinganisa | 1mmHg ~ 30mmHg/1mmHg~60mmHg (1mmHg) |
Inkqubo yokulinganisa | Ukukhanya kunye noxinzelelo inkqubo yokuva kabini |
Umgama wokusebenza | >= 11mm |
R/L(iliso lasekunene/lasekhohlo) | Ubhaqo oluzenzekelayo kunye nomboniso |
Isiphumo sokulinganisa | Amaxesha ali-10 ukulinganisa kunye namaxesha ama-3 aprinta iliso ngalinye |
Shicilela | Iprinta eyakhelwe-ngaphakathi |
Imodeli yokulinganisa | Iyazenzekela /ngesandla |
Gxininisa | Gxininisa indawo yokukhanya kwisakhelo sokugxila Imo ezenzekelayo: Umlinganiselo woxinzelelo lwe-intraocular ngokuzenzekelayo Imo yesandla: ugqaliselo oluhle, isakhelo sogqaliselo ukusuka kumthubi ukuya koluhlaza, cofa ukuqalisa umlinganiselo woxinzelelo lwe-intraocular |
Impazamo | Ukuba umqondiso wokulinganisa ubuthathaka, uxinzelelo lwe-intraocular luya kuba () vala okanye ubonise 'ERR' |
Iqhosha lomda wokhuseleko | Umgama osondeleyo phakathi kwentloko yokulinganisa kunye nesigulane unokumiselwa |
umsebenzi wokhuseleko | Umgama phakathi kwe-jet port kunye ne-cornea ilawulwa ngaphakathi koluhlu olusethiweyo (11 m).Xa intloko yejethi isondele kakhulu kwi-cornea, iyayeka ukuya phambili |
Hambisa uluhlu | 30mm (ngaphambili nangasemva) / 90mm (ekhohlo nasekunene) / 30mm (the nkqo) |
Isilevu siphumle | 0-65mm |
Bonisa | I-10.1inch HDMI isiboniso se-LED esinemibala, isikrini sokuchukumisa |
Isiphumo | USB2.0 |
Itafile yomsebenzi | Itafile yombane |
Ubungakanani | 380(L)*460(W)*505(H) |
Ubunzima | 19.7kg |
Cofa apha ukuze ufumane ixabiso !!!
Uhlobo:Izixhobo zeOphthalmic Optical
Indawo yeMvelaphi:CN;GUA
Ukuhlelwa kwesixhobo: Udidi II
Igama leBrand: Mecan
Inombolo yomzekelo: MCE-NCT10
Umzekelo: MCE-NCT10
I-tonometer ye-auto isebenzisa ulawulo lomfanekiso kunye nokuqondwa kweempawu ze-3-D ezizenzekelayo zokubeka indawo ye-xyz ngomgwebo othembekileyo kunye neziphumo zomlinganiselo, kwaye kulula ukuyisebenzisa.Indlela yokunxibelelana yomoya yokulinganisa i-IOP inokusetyenziselwa ukutyeba kwecorneal.
1.Ukuma kwe-3-D okuzenzekelayo kwexyz kubangela umlinganiselo ochanekileyo nothembekileyo
I-2.I-auto-auto measurement yedatha yeso lasekunene nasekhohlo ngaphandle kokutshintsha ngesandla
3.Kulula ukusebenzisa i-tonometer ngombala wokujonga umbala
I-4.Idatha ezinzileyo ye-IOP ngokulinganisa umoya othambileyo
5.Ukubuyisela umlinganiselo we-corneal ubukhulu be-IOP
Uluhlu lokulinganisa | 1mmHg ~ 30mmHg/1mmHg~60mmHg (1mmHg) |
Inkqubo yokulinganisa | Ukukhanya kunye noxinzelelo inkqubo yokuva kabini |
Umgama wokusebenza | >= 11mm |
R/L(iliso lasekunene/lasekhohlo) | Ubhaqo oluzenzekelayo kunye nomboniso |
Isiphumo sokulinganisa | Amaxesha ali-10 ukulinganisa kunye namaxesha ama-3 aprinta iliso ngalinye |
Shicilela | Iprinta eyakhelwe-ngaphakathi |
Imodeli yokulinganisa | Iyazenzekela /ngesandla |
Gxininisa | Gxininisa indawo yokukhanya kwisakhelo sokugxila Imo ezenzekelayo: Umlinganiselo woxinzelelo lwe-intraocular ngokuzenzekelayo Imo yesandla: ugqaliselo oluhle, isakhelo sogqaliselo ukusuka kumthubi ukuya koluhlaza, cofa ukuqalisa umlinganiselo woxinzelelo lwe-intraocular |
Impazamo | Ukuba uphawu lokulinganisa lubuthathaka, uxinzelelo lwe-intraocular luya kuba () vala okanye ubonise 'ERR' |
Iqhosha lomda wokhuseleko | Umgama osondeleyo phakathi kwentloko yokulinganisa kunye nesigulane unokumiselwa |
umsebenzi wokhuseleko | Umgama phakathi kwe-jet port kunye ne-cornea ilawulwa ngaphakathi koluhlu olusethiweyo (11 m).Xa intloko yejethi isondele kakhulu kwi-cornea, iyayeka ukuya phambili |
Hambisa uluhlu | 30mm (ngaphambili nangasemva) / 90mm (ekhohlo nasekunene) / 30mm (the nkqo) |
Isilevu siphumle | 0-65mm |
Bonisa | I-10.1inch HDMI isiboniso se-LED esinemibala, isikrini sokuchukumisa |
Isiphumo | USB2.0 |
Itafile yomsebenzi | Itafile yombane |
Ubungakanani | 380(L)*460(W)*505(H) |
Ubunzima | 19.7kg |