Samuwar: | |
---|---|
Yawan: | |
Saukewa: MCS0431
MeCan
Na gaba-gen electrosurgery: Independent endoscopy tashar jiragen ruwa, auto-yanayin sauya sheka, daidai iko iko, kurakurai saka idanu, da ruwa mai hana ruwa panel.Mafi kyawun aminci, inganci, da juzu'i a cikin raka'a ɗaya.
Unit Electrosurgical ya dace da tiyata daban-daban akan yanke ko coagulation, gami da aikin tiyata na gabaɗaya, zuciya, likitan mata, tiyatar anorectal, likitan kasusuwa, tiyatar thoracic, ƙari, da sauransu.
Hakanan ana amfani da sashin Electrosurgical tare da tiyatar endoscope, hysteroscope, laparoscope ENT endoscope, da sauransu. Ana iya amfani da bipolar a cikin mafi kyawun tiyata na microsurgery, neurologist, ENT da ophthalmology, aikin hannu, da sauransu.
1. Tashar tashar fitarwa mai zaman kanta na endoscope da maɓallin juyawa mai hankali, wanda zai iya shigar da yanayin endoscopic ta atomatik bayan farawa.
2. Tsarin kula da microcomputer, kariyar kashe wutar lantarki, da aikin ƙwaƙwalwa na adana bayanan amfani na ƙarshe bayan sake farawa.
3. Daidaita atomatik akan ikon fitarwa.Ana iya daidaita shi ta atomatik bisa ga canji a cikin yawa na nama.Tsayayyen ƙarfin fitarwa don kiyaye mafi ƙarancin ɓarna
4. Juyawa ta atomatik akan monopolar da bipolar
5. Saka idanu ta atomatik na kashewa, ganowa ta atomatik, da kuskuren kuskure a cikin aiki.
6. Tsarin kewayawa na saka idanu akan ingancin lambar sadarwa na na'urori masu tsaka-tsaki na iya gwadawa da kimanta aminci da tasiri na wurin lamba tsakanin farantin lantarki da fata.
7. Tsarin zai iya yanke fitarwa ta atomatik kuma ya ba da ƙararrawa, idan an gano cewa wurin sadarwar yana a matakin haɗari.Yana iya gwadawa da amfani da faranti mara kyau na monopolar ko bipolar yadda ya kamata.
8. Aiki panel tare da maɓalli, high definition, da kuma babban dijital.Yana da sauti daban-daban da alamun haske yayin aiki.Maɓallan aiki mai hana ruwa suna da sauƙin tsaftacewa da kulawa.
9. Fitar wutar lantarki mai zaman kanta ta hanyoyi uku.Wannan yana ƙara dacewa da tsaro na ayyuka.
10. Ana iya sarrafa shi kuma a yi shi da kyau a karkashin ruwa ko da lokacin da ake rarrabawa da cire kitse.
11. An dakatar da fitar da wutar lantarki gaba daya.Akwai sassan aikace-aikace masu zaman kansu guda biyu da keɓe don hana tsangwama na defibrillation (monopolar da bipolar).
Mono Yanke | Saukewa: 400W | Saukewa: 150W |
Mono Coag | Launi mai laushi: 100W | Ƙarfin ƙarfin: 80W |
Bip olar | Ƙarfin Bipolar: 50W |
Yanayin yanayin yanayi | 10 ℃ ~ 40 ℃ |
Yanayin zafi na dangi | 30% ~ 75% |
Kewayon matsa lamba na yanayi | 700hpa ~ 1060hpa |
Tushen wutan lantarki | 220V/110V,50Hz |
Mitar aiki | 360kHz - 460 kHz |
Nau'in kayan aiki | CF |
Amfanin wutar lantarki na na'urar gabaɗaya bai wuce 1000VA ba. (Aikin Yanke: 400W) |
Neutral Electrode
Bipolar Electrocoagulation Tweezers
Sauya Ƙafafun Bipolar
Kebul na monopolar
Electrosurgical Pencil
An ƙera maɓallin juyawa mai hankali don shigar da yanayin endoscopic ta atomatik yayin farawa, yana ba da sauye-sauye mara kyau da dacewa yayin matakai.
Tsarin sarrafa microcomputer yana ba da kariya ta kashe wuta da aikin ƙwaƙwalwar ajiya, yana tabbatar da cewa naúrar ta riƙe bayanan amfani na ƙarshe ko da bayan sake farawa.Wannan fasalin yana ba da damar ci gaba da sauƙin aiki.
Naúrar tana aiki da daidaitawa ta atomatik na ikon fitarwa bisa ga canje-canje a yawan ƙwayar nama.Ta hanyar daidaita ƙarfin wutar lantarki daidai da haka, yana kiyaye matakan ƙarfin ƙarfi kuma yana rage ɓata lokaci, yana haɓaka inganci.
Na gaba-gen electrosurgery: Independent endoscopy tashar jiragen ruwa, auto-yanayin sauya sheka, daidai iko iko, kurakurai saka idanu, da ruwa mai hana ruwa panel.Mafi kyawun aminci, inganci, da juzu'i a cikin raka'a ɗaya.
Unit Electrosurgical ya dace da tiyata daban-daban akan yanke ko coagulation, gami da aikin tiyata na gabaɗaya, zuciya, likitan mata, tiyatar anorectal, likitan kasusuwa, tiyatar thoracic, ƙari, da sauransu.
Hakanan ana amfani da sashin Electrosurgical tare da tiyatar endoscope, hysteroscope, laparoscope ENT endoscope, da sauransu. Ana iya amfani da bipolar a cikin mafi kyawun tiyata na microsurgery, neurologist, ENT da ophthalmology, aikin hannu, da sauransu.
1. Tashar tashar fitarwa mai zaman kanta na endoscope da maɓallin juyawa mai hankali, wanda zai iya shigar da yanayin endoscopic ta atomatik bayan farawa.
2. Tsarin kula da microcomputer, kariyar kashe wutar lantarki, da aikin ƙwaƙwalwar ajiya na adana bayanan amfani na ƙarshe bayan sake farawa.
3. Daidaita atomatik akan ikon fitarwa.Ana iya daidaita shi ta atomatik bisa ga canji a cikin yawa na nama.Tsayayyen ƙarfin fitarwa don kiyaye mafi ƙarancin ɓarna
4. Juyawa ta atomatik akan monopolar da bipolar
5. Saka idanu ta atomatik na kashewa, ganowa ta atomatik, da kuskuren kuskure a cikin aiki.
6. Tsarin kewayawa na saka idanu akan ingancin lambar sadarwa na na'urori masu tsaka-tsaki na iya gwadawa da kimanta aminci da tasiri na wurin lamba tsakanin farantin lantarki da fata.
7. Tsarin zai iya yanke fitarwa ta atomatik kuma ya ba da ƙararrawa, idan an gano cewa wurin sadarwar yana a matakin haɗari.Yana iya gwadawa da amfani da faranti mara kyau na monopolar ko bipolar yadda ya kamata.
8. Aiki panel tare da maɓalli, high definition, da kuma babban dijital.Yana da sauti daban-daban da alamun haske yayin aiki.Maɓallan aiki mai hana ruwa suna da sauƙin tsaftacewa da kulawa.
9. Fitar wutar lantarki mai zaman kanta ta hanyoyi uku.Wannan yana ƙara dacewa da tsaro na ayyuka.
10. Ana iya sarrafa shi kuma a yi shi da kyau a karkashin ruwa ko da lokacin da ake rarrabawa da cire kitse.
11. An dakatar da fitar da wutar lantarki gaba daya.Akwai sassan aikace-aikace masu zaman kansu guda biyu da keɓe don hana tsangwama na defibrillation (monopolar da bipolar).
Mono Yanke | Saukewa: 400W | Saukewa: 150W |
Mono Coag | Launi mai laushi: 100W | Ƙarfin ƙarfin: 80W |
Bip olar | Ƙarfin Bipolar: 50W |
Yanayin yanayin yanayi | 10 ℃ ~ 40 ℃ |
Yanayin zafi na dangi | 30% ~ 75% |
Kewayon matsa lamba na yanayi | 700hpa ~ 1060hpa |
Tushen wutan lantarki | 220V/110V,50Hz |
Mitar aiki | 360kHz - 460 kHz |
Nau'in kayan aiki | CF |
Amfanin wutar lantarki na na'urar gabaɗaya bai wuce 1000VA ba. (Aikin Yanke: 400W) |
Neutral Electrode
Bipolar Electrocoagulation Tweezers
Sauya Ƙafafun Bipolar
Kebul na monopolar
Electrosurgical Pencil
An ƙera maɓallin juyawa mai hankali don shigar da yanayin endoscopic ta atomatik yayin farawa, yana ba da sauye-sauye mara kyau da dacewa yayin matakai.
Tsarin sarrafa microcomputer yana ba da kariya ta kashe wuta da aikin ƙwaƙwalwar ajiya, yana tabbatar da cewa naúrar ta riƙe bayanan amfani na ƙarshe ko da bayan sake farawa.Wannan fasalin yana ba da damar ci gaba da sauƙin aiki.
Naúrar tana aiki da daidaitawa ta atomatik na ƙarfin fitarwa dangane da canje-canje a yawan ƙwayar nama.Ta hanyar daidaita wutar lantarki daidai da haka, yana kiyaye matakan ƙarfin ƙarfi kuma yana rage ɓata lokaci, yana haɓaka inganci.