Kayan aikin Laboratory Medical Buɗe Reagent 3 Diff Auto Hematology Analyzer Farashin
3 Diff Auto Hematology Analyzer
Saukewa: MCL-KT-6300
Ayyukan Nazartar Hematology:
Abu | Daidaitawa, CV |
WBC | ≤2.0% |
RBC | ≤1.9% |
HGB | ≤1.9% |
MCV | ≤0.4% |
PLT | ≤4.0% |
Ci gaba | WBC ≤2% , RBC ≤1% , HGB ≤2% , PLT ≤2% |
Ƙayyadaddun Ma'anar Hematology Auto Analyzer:
Net nauyi: 18Kg
Harshe: Turanci
Tashar gwaji: tashoshi biyu
Kayan aiki: 60 samfurori / awa
Gwajin gwaji: cikakken auto kuma jinin baya buƙatar tsarma ko wani tsari
Siga: Banbancin kashi 3 na ,sigogin WBC 20 + 3 histograms
T est ka'ida: juriya na lantarki don kirgawa da hanyar SFT don HGB
Clot clear: high voltage burn and high pressure flushing
Samfurin girma: 9.8μl na gefe jini ko venous jini
Yanayin QC: X , X -R , X -B ,L-J, zana atomatik da buga adadi QC
Reagent: samar da reagent na asali
Nau'in Nau'in Nasiha: Yara ,jarirai ,namiji ,mace da na duniya
Ƙwaƙwalwar ajiya: adana sama da 30000 dalla-dalla sakamakon samfurin ciki har da histograms
Nuni: Babban LCD launi, nuna duk sigogi da histograms a allo ɗaya
Shigarwa da fitarwa: linzamin kwamfuta ,na ,Parallel Port ,RS232 serial port, ana iya haɗa shi da kwamfuta
Yanayin gyare-gyare: Yanayin atomatik da yanayin jagora ana iya zaɓar su, samar da na'urar ƙira da sarrafawa na asali
Printer: Za a iya haɗa firinta ta thermal ,zuwa kwamfuta ta waje da firinta
Yanayin Aiki: Zazzabi : 18°C ~ 35°C;Yanayin zafi : 40% RH-80% RH
Voltage: AC 175 V ~ 265V ,Auto daidaitawa bisa ga shigar da ƙarfin lantarki
Girma: 300mm × 400mm × 440mm ( L×W×H )
Ma'aunin Gwaji na Mai Binciken Hematology:
WBC Lymph# Mid# Gran# Lymph% Tsakanin% Gran% RBC HGB HCT
MCV MCH MCHC RDW-SD RDW-CV PLT MPV PDW PCT P-LCR
WBC Histogram RBC Histogram PLT Histogram
Ma'aunin Fasaha na Kayan aikin Hematology:
Samfurin girma: yanayin al'ada: 9.8μl, yanayin dilution: 20 μl
Diamita na buɗewa: WBC: 100μm, RBC ,PLT: 70μm
Kayan aiki: 60 samfurori / awa
Clot clear: high voltage burn and high pressure flushing
Muna ba da nau'ikan Analyzer na Laboratory daban-daban.Ana nuna wasu a cikin hotuna masu zuwa.Don ƙarin bayani, da fatan za a duba shafin yanar gizon mu: guangzhou-medical.en.alibaba.com.
Injin Anesthesia | Autoclave | Na'urar Ultrasound |Launi Doppler Ultrasound | Defibrillator | Likitan Firiji | Centrifuge | Kujerar hakori | Sashin ENT | Injin ECG | Mai Kula da Mara lafiya | Endoscope | Bidiyo Gastroscope Colonoscope | Kayan Aikin Asibiti | Incubator na jarirai | Jaririn Radiant Warmer | Kayan Aikin Lantarki na Clinical | Biochemistry Analyzer | Hematology Analyzer | Coagulometer | Analyzer ESR |DInjin ialysis | Lab Incubator |Ruwa Bath | Ruwa Distiller | Microscope | Kayan aikin Jiki | Kayan aikin OB/GYN | Colposcope | Fitilar Slit | Kayayyakin Ophthamoc | Ƙarfin Ƙarfin Tiyata | Tebur Aiki | Hasken Aiki | Mai ba da iska | Injin X-ray | Mai sarrafa fim | Kayan Aikin Dabbobi .......
1. Mai ba da tasha ɗaya don kayan aikin likita da kayan aikin dakin gwaje-gwaje a Guangzhou
2. Sama da asibitoci 2000 sun zama abokan aikinmu
3. Kyakkyawan inganci tare da farashin masana'anta
4. Amsa da sauri da sabis na kulawa
5. CE, ISO, Takaddun FDA
6. Isar da sauri ta iska, teku ko a wasu hanyoyi
7. Fiye da shekaru 10 a cikin injiniyoyin likita suna ba da kasuwanci
8. Ana fitar dashi zuwa kasashe fiye da 109
9. Lokacin garanti: A KALLA watanni 12 da Sama da shekaru 8 fasaha da kayan haɗi-canji goyon baya
10.Excellent da nan da nan bayan-sayar sabis
1. Daga Injiniya Biomedical na Senegal.
sannu, shigar da sashin RX yayi nasara.duk yayi kyau kuma ina da hoto mai kyau.
NA GODE
2. Daga Dr. Salman Hasan, Likita daga Nigeria
Assalamu alaikum mun sanya rediyon kuma mun gamsu da yadda ake gudanar da shi.
3. Daga Dr. Emma Adapoe, Ghana, Afrika.
Mecan Medical Company Limited kasuwar kasuwa
Na gwada su don gaskiyarsu
Na gwada samfuran su don Kyakkyawan inganci
Na dandana mai kyau kuma mai kyau sabis da abokan ciniki
Na amince da Mecan saboda sun tsaya gwajin lokaci.
Da fatan za a tuntuɓe mu kuma bari mu yi magana dalla-dalla don 3 Diff Auto Hematology Analyzer.
Nau'i: Tsarin Nazarin Jini
Wurin Asalin:CN;GUA
Rarraba kayan aiki: Class II
Garanti: 1 shekara
Sabis na Bayan-tallace: Tallafin Fasaha na Kan layi
Brand Name: MeCan
Lambar samfur: MCL-KT-6300
Kayan aikin Laboratory Medical Buɗe Reagent 3 Diff Auto Hematology Analyzer Farashin
3 Diff Auto Hematology Analyzer
Saukewa: MCL-KT-6300
Ayyukan Nazartar Hematology:
Abu | Daidaitawa, CV |
WBC | ≤2.0% |
RBC | ≤1.9% |
HGB | ≤1.9% |
MCV | ≤0.4% |
PLT | ≤4.0% |
Ci gaba | WBC ≤2% , RBC ≤1% , HGB ≤2% , PLT ≤2% |
Ƙayyadaddun Ma'anar Hematology Auto Analyzer:
Net nauyi: 18Kg
Harshe: Turanci
Tashar gwaji: tashoshi biyu
Kayan aiki: 60 samfurori / awa
Gwajin gwaji: cikakken auto kuma jinin baya buƙatar tsarma ko wani tsari
Siga: Banbancin kashi 3 na ,sigogin WBC 20 + 3 histograms
T est ka'ida: juriya na lantarki don kirgawa da hanyar SFT don HGB
Clot clear: high voltage burn and high pressure flushing
Samfurin girma: 9.8μl na gefe jini ko venous jini
Yanayin QC: X , X -R , X -B ,L-J, zana atomatik da buga adadi QC
Reagent: samar da reagent na asali
Nau'in Nau'in Nasiha: Yara ,jarirai ,namiji ,mace da na duniya
Ƙwaƙwalwar ajiya: adana sama da 30000 dalla-dalla sakamakon samfurin ciki har da histograms
Nuni: Babban LCD launi, nuna duk sigogi da histograms a allo ɗaya
Shigarwa da fitarwa: linzamin kwamfuta ,na ,Parallel Port ,RS232 serial port, ana iya haɗa shi da kwamfuta
Yanayin gyare-gyare: Yanayin atomatik da yanayin jagora ana iya zaɓar su, samar da na'urar ƙira da sarrafawa na asali
Printer: Za a iya haɗa firinta ta thermal ,zuwa kwamfuta ta waje da firinta
Yanayin Aiki: Zazzabi : 18°C ~ 35°C;Yanayin zafi : 40% RH-80% RH
Voltage: AC 175 V ~ 265V ,Auto daidaitawa bisa ga shigar da ƙarfin lantarki
Girma: 300mm × 400mm × 440mm ( L×W×H )
Ma'aunin Gwaji na Mai Binciken Hematology:
WBC Lymph# Mid# Gran# Lymph% Tsakanin% Gran% RBC HGB HCT
MCV MCH MCHC RDW-SD RDW-CV PLT MPV PDW PCT P-LCR
WBC Histogram RBC Histogram PLT Histogram
Ma'aunin Fasaha na Kayan aikin Hematology:
Samfurin girma: yanayin al'ada: 9.8μl, yanayin dilution: 20 μl
Diamita na buɗewa: WBC: 100μm, RBC ,PLT: 70μm
Kayan aiki: 60 samfurori / awa
Clot clear: high voltage burn and high pressure flushing
Muna ba da nau'ikan Analyzer na Laboratory daban-daban.Ana nuna wasu a cikin hotuna masu zuwa.Don ƙarin bayani, da fatan za a duba shafin yanar gizon mu: guangzhou-medical.en.alibaba.com.
Injin Anesthesia | Autoclave | Na'urar Ultrasound |Launi Doppler Ultrasound | Defibrillator | Likitan Firiji | Centrifuge | Kujerar hakori | Sashin ENT | Injin ECG | Mai Kula da Mara lafiya | Endoscope | Bidiyo Gastroscope Colonoscope | Kayan Aikin Asibiti | Incubator na jarirai | Jaririn Radiant Warmer | Kayan Aikin Lantarki na Clinical | Biochemistry Analyzer | Hematology Analyzer | Coagulometer | Analyzer ESR |DInjin ialysis | Lab Incubator |Ruwa Bath | Ruwa Distiller | Microscope | Kayan aikin Jiki | Kayan aikin OB/GYN | Colposcope | Fitilar Slit | Kayayyakin Ophthamoc | Ƙarfin Ƙarfin Tiyata | Tebur Aiki | Hasken Aiki | Mai ba da iska | Injin X-ray | Mai sarrafa fim | Kayan Aikin Dabbobi .......
1. Mai ba da tasha ɗaya don kayan aikin likita da kayan aikin dakin gwaje-gwaje a Guangzhou
2. Sama da asibitoci 2000 sun zama abokan aikinmu
3. Kyakkyawan inganci tare da farashin masana'anta
4. Amsa da sauri da sabis na kulawa
5. CE, ISO, Takaddun FDA
6. Isar da sauri ta iska, teku ko a wasu hanyoyi
7. Fiye da shekaru 10 a cikin injiniyoyin likita suna ba da kasuwanci
8. Ana fitar dashi zuwa kasashe fiye da 109
9. Lokacin garanti: A KALLA watanni 12 da Sama da shekaru 8 fasaha da kayan haɗi-canji goyon baya
10.Excellent da nan da nan bayan-sayar sabis
1. Daga Injiniya Biomedical na Senegal.
sannu, shigar da sashin RX yayi nasara.duk yayi kyau kuma ina da hoto mai kyau.
NA GODE
2. Daga Dr. Salman Hasan, Likita daga Nigeria
Assalamu alaikum mun sanya rediyon kuma mun gamsu da yadda ake gudanar da shi.
3. Daga Dr. Emma Adapoe, Ghana, Afrika.
Mecan Medical Company Limited kasuwar kasuwa
Na gwada su don gaskiyarsu
Na gwada samfuran su don Kyakkyawan inganci
Na dandana mai kyau kuma mai kyau sabis da abokan ciniki
Na amince da Mecan saboda sun tsaya gwajin lokaci.
Da fatan za a tuntuɓe mu kuma bari mu yi magana dalla-dalla don 3 Diff Auto Hematology Analyzer.