I-Defibrillator Monitor xa kuthelekiswa neemveliso ezifanayo kwiimarike, ineenzuzo ezibalaseleyo ezingenakuqhathaniswa ngokubhekiselele ekusebenzeni, umgangatho, ukubonakala, njl., kwaye uyonwabela idumela elihle kwimarike.MeCan Medical ishwankathela iziphene zeemveliso ezidlulileyo, kwaye ngokuqhubekayo iphucula.
Ubukho: | |
---|---|
Ubuninzi: | |
Umgangatho oPhezulu woNcedo lokuQala oluphathekayo lwentliziyo ephathwayo kwi-Medical Defibrillator Monitor
Umzekelo: MCS-DE01
Umsebenzi obanzi:
Nge-Defibrillation, i-Pacing, i-Monitoring kunye ne-AED mode, i-MCS-DE01 ayifanelekanga kuphela kwi-pre-hospital first aid, kodwa iyasebenza nasekusetyenzisweni kwesibhedlele.
1. I-Defibrillation: Iindlela ze-Manual defibrillation ziquka i-cardioversion ye-synchronous kunye ne-asynchronous defibrillation.
2. I-Pacing: Ukuba ne-pacing efunekayo kunye ne-fixed pacing mode, kwizigulana ezibanjwe yintliziyo kunye ne-arrhythmia enzima kakhulu, i-in vitro i-non-invasive pacing mode ikhawuleza, kulula ukuyiqonda, ukonga ixesha kunye nokuphucula izinga lokuphumelela.
3. I-AED: Imodeli isebenzisa i-algorithm yohlalutyo lwelungelo lomenzi kunye nohlalutyo oluzenzekelayo kunye nokuseta ngokufanelekileyo ukukhokela abasebenzi bezonyango abangxamisekileyo ekuboneleleni nge-defibrillation kunye nesiseko senkxaso yobomi.
4. Ukubeka iliso: I-5-lead ECG esweni njengomgangatho, imisebenzi ekhethiweyo yokubeka iliso ibandakanya i-SpO2, i-NIBP, i-PR kunye ne-EtCO2 nazo ziyafumaneka ngokuqhubekayo ukubeka iliso kwiimpawu ezibalulekileyo zesigulane.
Iluncedo kwaye iyasebenza
Njengeyona nxalenye ibalulekileyo yeCPR, ixesha liyisitshixo se-defibrillator monitor.Ke ngoko, i-MCS-DE01 ishiya umsebenzi onzima kwaye iphucule lula kunye nokusebenza kakuhle kokuhlangula.
I-knob ye-1 : Imodi inokutshintshwa phakathi kwe-defibrillation ye-manual, i-pacing kunye ne-AED.Kwi-defibrillation ye-manual, umsebenzisi unokugqiba ukhetho lwamandla ngaphakathi kwe-1 yesibini.
I-3s : Intlawulo ye-Defibrillator kwi-200J kunye nokutshatyalaliswa kwimizuzwana ye-3, ixesha lokuhlangula liqinisekisiwe ngokupheleleyo.
Amanyathelo ama-3 : Gcwalisa umsebenzi wokunciphisa i-fibrillating (Ukukhetha amandla ‒ Ukutshaja ‒ Ukukhupha).
Iintlobo ze-25 : Ukukhetha amandla.
I-1 pair : Ukusebenza kwe-Defibrillating kunokugqitywa kwi-pair of electrode paddles.Iipali zabantwana ezakhiwe kwiipaddles zabantu abadala.
I-1 ye-2 : I-Electrode paddles inokwahlulwa ibe yi-electrode paddles enkulu kunye encinci enokuthi i-defibrillate kumntu omdala kunye nomntwana ngokulandelanayo.
Ephakamileyo nangaphezulu:
Ukuya kuthi ga kwi -360J ukhetho lwamandla, kwizigulane ezineemiguvela eziphezulu ze-defibrillation ezifana ne-myocardial infarction, ukukhuluphala, i-impedance ephezulu, ukukhethwa kwamandla aphezulu kubonisa izinga eliphezulu lokuphumelela kwe-defibrillation.
I-Impedance Range enkulu ukusuka kwi -20-300Ω , ilungele uluhlu olukhulu lwezigulane.
Ukusebenza okuphezulu kunye neTekhnoloji ye-Biphasic Truncated Exponential (BTE) ye-waveform ye-waveform kunye nembuyekezo ye-impedance ezenzekelayo.
Yima njengoko ufuna uphononongo njengoko ucela:
Umgangatho othembekileyo ubusoloko ikukusukela abasebenzi be-COMEN R&D.Njengesixhobo soncedo lokuqala, i-defibrillator isoloko isetyenziswa kwiindawo ezigqithisileyo, apho ukuthembeka kwayo kugxininiswa kwiimeko ezahlukeneyo.
I-Anti-mothuko kunye ne-anti-kuwa, yomelele kwaye yomelele.Ngokhuseleko lokungena kwe-IPX4, i-S5 iyakunqanda ukungena kolwelo kwaye inokusetyenziswa kwindawo enzima yangaphandle. | Ibhetri ye-lithium enkulu, ixhasa ukutshaja ngokukhawuleza ukuya kuma-210 amaxesha okukhutshwa okukhulu, ukwanelisa iimfuno zeklinikhi. | Ngemanuwali, ngokuzenzekelayo, umsebenzi wokuqalisa ukuzivavanya, uqinisekisa isicelo nangaliphi na ixesha. |
Umshicileli we-50mm we-thermal, iifom zamaza zicace ngakumbi kwaye zichanekile. | Inkxaso ye-240 imizuzu ye-AED yokugcinwa kwelizwi, ukurekhoda kwesigulane ngasinye kunokugcinwa ukuya kwimizuzu engama-60. | Uphononongo lwemisitho emininzi, intsingiselo kunye nokugcinwa kwedatha. |
Isisombululo seNethiwekhi esekwe kuLwazi:
Ibonelela ngesisombululo esibanzi sothungelwano, esivumela abasebenzisi ukuba bafikelele kulwazi lwesigulana kunye nokuphucula ukusebenza kakuhle xa kuyimfuneko.
Ukusebenza kwemveliso kunokwethenjelwa kwaye ubomi bayo benkonzo bude.
Umgangatho oPhezulu woNcedo lokuQala oluphathekayo lwentliziyo ephathwayo kwi-Medical Defibrillator Monitor
Umzekelo: MCS-DE01
Umsebenzi obanzi:
Nge-Defibrillation, i-Pacing, i-Monitoring kunye ne-AED mode, i-MCS-DE01 ayifanelekanga kuphela kwi-pre-hospital first aid, kodwa iyasebenza nasekusetyenzisweni kwesibhedlele.
1. I-Defibrillation: Iindlela ze-Manual defibrillation ziquka i-cardioversion ye-synchronous kunye ne-asynchronous defibrillation.
2. I-Pacing: Ukuba ne-pacing efunekayo kunye ne-fixed pacing mode, kwizigulana ezibanjwe yintliziyo kunye ne-arrhythmia enzima kakhulu, i-in vitro i-non-invasive pacing mode ikhawuleza, kulula ukuyiqonda, ukonga ixesha kunye nokuphucula izinga lokuphumelela.
3. I-AED: Imodeli isebenzisa i-algorithm yohlalutyo lwelungelo lomenzi kunye nohlalutyo oluzenzekelayo kunye nokuseta ngokufanelekileyo ukukhokela abasebenzi bezonyango abangxamisekileyo ekuboneleleni nge-defibrillation kunye nesiseko senkxaso yobomi.
4. Ukubeka iliso: I-5-lead ECG esweni njengomgangatho, imisebenzi ekhethiweyo yokubeka iliso ibandakanya i-SpO2, i-NIBP, i-PR kunye ne-EtCO2 nazo ziyafumaneka ngokuqhubekayo ukubeka iliso kwiimpawu ezibalulekileyo zesigulane.
Iluncedo kwaye iyasebenza
Njengeyona nxalenye ibalulekileyo yeCPR, ixesha liyisitshixo se-defibrillator monitor.Ke ngoko, i-MCS-DE01 ishiya umsebenzi onzima kwaye iphucule lula kunye nokusebenza kakuhle kokuhlangula.
I-knob ye-1 : Imodi inokutshintshwa phakathi kwe-defibrillation ye-manual, i-pacing kunye ne-AED.Kwi-defibrillation ye-manual, umsebenzisi unokugqiba ukhetho lwamandla ngaphakathi kwe-1 yesibini.
I-3s : Intlawulo ye-Defibrillator kwi-200J kunye nokutshatyalaliswa kwimizuzwana ye-3, ixesha lokuhlangula liqinisekisiwe ngokupheleleyo.
Amanyathelo ama-3 : Gcwalisa umsebenzi wokunciphisa i-fibrillating (Ukukhetha amandla ‒ Ukutshaja ‒ Ukukhupha).
Iintlobo ze-25 : Ukukhetha amandla.
I-1 pair : Ukusebenza kwe-Defibrillating kunokugqitywa kwi-pair of electrode paddles.Iipali zabantwana ezakhiwe kwiipaddles zabantu abadala.
I-1 ye-2 : I-Electrode paddles inokwahlulwa ibe yi-electrode paddles enkulu kunye encinci enokuthi i-defibrillate kumntu omdala kunye nomntwana ngokulandelanayo.
Ephakamileyo nangaphezulu:
Ukuya kuthi ga kwi -360J ukhetho lwamandla, kwizigulane ezineemiguvela eziphezulu ze-defibrillation ezifana ne-myocardial infarction, ukukhuluphala, i-impedance ephezulu, ukukhethwa kwamandla aphezulu kubonisa izinga eliphezulu lokuphumelela kwe-defibrillation.
I-Impedance Range enkulu ukusuka kwi -20-300Ω , ilungele uluhlu olukhulu lwezigulane.
Ukusebenza okuphezulu kunye neTekhnoloji ye-Biphasic Truncated Exponential (BTE) ye-waveform ye-waveform kunye nembuyekezo ye-impedance ezenzekelayo.
Yima njengoko ufuna uphononongo njengoko ucela:
Umgangatho othembekileyo ubusoloko ikukusukela abasebenzi be-COMEN R&D.Njengesixhobo soncedo lokuqala, i-defibrillator isoloko isetyenziswa kwiindawo ezigqithisileyo, apho ukuthembeka kwayo kugxininiswa kwiimeko ezahlukeneyo.
I-Anti-mothuko kunye ne-anti-kuwa, yomelele kwaye yomelele.Ngokhuseleko lokungena kwe-IPX4, i-S5 iyakunqanda ukungena kolwelo kwaye inokusetyenziswa kwindawo enzima yangaphandle. | Ibhetri ye-lithium enkulu, ixhasa ukutshaja ngokukhawuleza ukuya kuma-210 amaxesha okukhutshwa okukhulu, ukwanelisa iimfuno zeklinikhi. | Ngemanuwali, ngokuzenzekelayo, umsebenzi wokuqalisa ukuzivavanya, uqinisekisa isicelo nangaliphi na ixesha. |
Umshicileli we-50mm we-thermal, iifom zamaza zicace ngakumbi kwaye zichanekile. | Inkxaso ye-240 imizuzu ye-AED yokugcinwa kwelizwi, ukurekhoda kwesigulane ngasinye kunokugcinwa ukuya kwimizuzu engama-60. | Uphononongo lwemisitho emininzi, intsingiselo kunye nokugcinwa kwedatha. |
Isisombululo seNethiwekhi esekwe kuLwazi:
Ibonelela ngesisombululo esibanzi sothungelwano, esivumela abasebenzisi ukuba bafikelele kulwazi lwesigulana kunye nokuphucula ukusebenza kakuhle xa kuyimfuneko.
Ukusebenza kwemveliso kunokwethenjelwa kwaye ubomi bayo benkonzo bude.