I-Defibrillator Monitor uma iqhathaniswa nemikhiqizo efanayo emakethe, inezinzuzo ezivelele ezingenakuqhathaniswa ngokusebenza, ikhwalithi, ukubukeka, njll., futhi ijabulela idumela elihle emakethe.I-MeCan Medical ifingqa iziphambeko zemikhiqizo edlule, futhi iqhubeka ithuthukisa.
Ukutholakala: | |
---|---|
Ubuningi: | |
Ikhwalithi Ephakeme Yosizo Lokuqala Lwenhliziyo Ephathwayo I-Medical Defibrillator Monitor
Imodeli: MCS-DE01
Umsebenzi ophelele:
Ngemodi ye-Defibrillation, Pacing, Monitoring kanye ne-AED, i-MCS-DE01 ayifanele kuphela usizo lokuqala lwangaphambi kwesibhedlela, kodwa futhi iyasebenza ekusetshenzisweni esibhedlela.
1. I-Defibrillation: Izindlela ze-Manual defibrillation zihlanganisa i-synchronous cardioversion kanye ne-asynchronous defibrillation.
2. I-Pacing: Ukuba ne-pacing efunwa kakhulu kanye ne-fixed pacing mode, ezigulini ezinokuboshwa kwenhliziyo kanye ne-acute acute arrhythmia ehamba kancane, imodi ye-in vitro non-invasive pacing iyashesha, kulula ukuyiqonda, yonga isikhathi futhi ithuthukisa izinga lempumelelo yokululama.
3. I-AED: Imodeli isebenzisa i-algorithm yokuhlaziya enelungelo lobunikazi kanye nokuhlaziya okuzenzakalelayo kanye nesilungiselelo esikahle sokuqondisa abasebenzi bezimo eziphuthumayo zomtholampilo ekunikezeni i-defibrillation kanye nokwesekwa kwempilo okuyisisekelo.
4. Gada: Ukuqapha kwe-ECG okuhola phambili okungu-5 njengokujwayelekile, imisebenzi yokuqapha okukhethwa kukho ihlanganisa i-SpO2, i-NIBP, i-PR ne-EtCO2 nayo iyatholakala ukuze kuqashwe izimpawu ezibalulekile zesiguli.
Elula futhi Ephumelelayo
Njengengxenye ebaluleke kakhulu ye-CPR, isikhathi siyisihluthulelo se-defibrillator monitor.Ngakho-ke, i-MCS-DE01 ishiya ukusebenza okuyinkimbinkimbi futhi ithuthukise ukunethezeka nokusebenza kahle kokuhlenga.
I-knob engu-1 : Imodi ingashintshwa phakathi kwe-defibrillation manual, i-pacing kanye ne-AED.Ekwenzeni i-fibrillation okwenziwa ngesandla, umsebenzisi angaqedela ukukhetha kwamandla phakathi nesekhondi elingu-1.
I-3s : Ukushaja i-Defibrillator ku-200J nokushaqeka kumasekhondi angu-3, isikhathi sokuhlenga siqinisekisiwe ngokugcwele.
Izinyathelo ezi-3 : Gcwalisa umsebenzi wokukhipha i-fibrillating (Ukukhetha amandla ‒ Ukushaja ‒ Ukushaja).
Izinhlobo ezingama-25 : Izinketho zamandla.
Ipheya elingu-1 : Umsebenzi wokukhipha i-fibrillating ungaqedelwa kumapheya ama-electrode paddles.Izigwedlo zezingane ezakhiwe ngezigwedlo zabantu abadala.
Oku-1 kokungu-2 : Izigwedlo ze-Electrode zingahlukaniswa zibe izigwedlo ezinkulu nezincane zama-electrode ezingakwazi ukwenza i-fibrillate kubo bobabili abadala kanye nengane ngokulandelanayo.
Okuphezulu nangaphezulu:
Kufika ku -360J ekukhethweni kwamandla, ezigulini ezinemikhawulo ephezulu ye-defibrillation efana ne-myocardial infarction, ukukhuluphala, i-impedance ephezulu, ukukhethwa kwamandla aphezulu kubonisa izinga eliphezulu lokuphumelela kwe-defibrillation.
I-Greater Impedance Range kusuka ku -20-300Ω , ilungele uhla olukhulu lweziguli.
Ukusebenza kahle okuphezulu ngobuchwepheshe be-waveform obuthuthukisiwe be-Biphasic Truncated Exponential (BTE) kanye nesinxephezelo se-impedance esizenzakalelayo.
Ilindile njengoba udinga ukubuyekezwa njengoba ucela:
Izinga elithembekile belilokhu lifuna abasebenzi be-COMEN R&D.Njengedivayisi yosizo lokuqala, i-defibrillator ivame ukusetshenziswa ezindaweni eziyingozi kakhulu, lapho ukwethembeka kwayo kugqanyiswa khona ezimeni ezihlukahlukene.
I-Anti- shock and anti- fall, iqinile futhi ihlala isikhathi eside.Ngokuvikela kwe-IPX4 Ingress, i-S5 igwema ukungena koketshezi futhi ingasetshenziswa endaweni engaphandle eyinkimbinkimbi. | Ibhethri ye-lithium enomthamo omkhulu, isekela ukushaja ngokushesha kuze kufike ezikhathini ezingu-210 zokukhishwa okukhulu, ukwanelisa izidingo zomtholampilo. | Ngomsebenzi wokuzihlola owenziwe ngesandla, ozenzakalelayo, wokuziqalisa, uqinisekisa uhlelo lokusebenza nganoma yisiphi isikhathi. |
Iphrinta eshisayo engu-50mm, amagagasi acacile futhi anembe kakhulu. | Sekela imizuzu engama-240 yesitoreji sokuqoshwa kwezwi se-AED, ukuqoshwa kwesiguli ngasinye kungagcinwa kuze kube yimizuzu engama-60. | Ukubuyekezwa kwemicimbi eminingi, okuthrendayo nokugcinwa kwedatha. |
Isixazululo senethiwekhi esisekelwe kulwazi:
Ihlinzeka ngesixazululo esibanzi sokuxhumana, esivumela abasebenzisi ukuthi bafinyelele ulwazi lwesiguli futhi bathuthukise ukusebenza kahle komsebenzi lapho kudingeka.
Ukusebenza komkhiqizo kuthembekile futhi impilo yayo yesevisi yinde.
Ikhwalithi Ephakeme Yosizo Lokuqala Lwenhliziyo Ephathwayo I-Medical Defibrillator Monitor
Imodeli: MCS-DE01
Umsebenzi ophelele:
Ngemodi ye-Defibrillation, Pacing, Monitoring kanye ne-AED, i-MCS-DE01 ayifanele kuphela usizo lokuqala lwangaphambi kwesibhedlela, kodwa futhi iyasebenza ekusetshenzisweni esibhedlela.
1. I-Defibrillation: Izindlela ze-Manual defibrillation zihlanganisa i-synchronous cardioversion kanye ne-asynchronous defibrillation.
2. I-Pacing: Ukuba ne-pacing efunwa kakhulu kanye ne-fixed pacing mode, ezigulini ezinokuboshwa kwenhliziyo kanye ne-acute acute arrhythmia ehamba kancane, imodi ye-in vitro non-invasive pacing iyashesha, kulula ukuyiqonda, yonga isikhathi futhi ithuthukisa izinga lempumelelo yokululama.
3. I-AED: Imodeli isebenzisa i-algorithm yokuhlaziya enelungelo lobunikazi kanye nokuhlaziya okuzenzakalelayo kanye nesilungiselelo esikahle sokuqondisa abasebenzi bezimo eziphuthumayo zomtholampilo ekunikezeni i-defibrillation kanye nokwesekwa kwempilo okuyisisekelo.
4. Gada: Ukuqapha kwe-ECG okuhola phambili okungu-5 njengokujwayelekile, imisebenzi yokuqapha okukhethwa kukho ihlanganisa i-SpO2, i-NIBP, i-PR ne-EtCO2 nayo iyatholakala ukuze kuqashwe izimpawu ezibalulekile zesiguli.
Elula futhi Ephumelelayo
Njengengxenye ebaluleke kakhulu ye-CPR, isikhathi siyisihluthulelo se-defibrillator monitor.Ngakho-ke, i-MCS-DE01 ishiya ukusebenza okuyinkimbinkimbi futhi ithuthukise ukunethezeka nokusebenza kahle kokuhlenga.
I-knob engu-1 : Imodi ingashintshwa phakathi kwe-defibrillation manual, i-pacing kanye ne-AED.Ekwenzeni i-fibrillation okwenziwa ngesandla, umsebenzisi angaqedela ukukhetha kwamandla phakathi nesekhondi elingu-1.
I-3s : Ukushaja i-Defibrillator ku-200J nokushaqeka kumasekhondi angu-3, isikhathi sokuhlenga siqinisekisiwe ngokugcwele.
Izinyathelo ezi-3 : Gcwalisa umsebenzi wokukhipha i-fibrillating (Ukukhetha amandla ‒ Ukushaja ‒ Ukushaja).
Izinhlobo ezingama-25 : Izinketho zamandla.
Ipheya elingu-1 : Umsebenzi wokukhipha i-fibrillating ungaqedelwa kumapheya ama-electrode paddles.Izigwedlo zezingane ezakhiwe ngezigwedlo zabantu abadala.
Oku-1 kokungu-2 : Izigwedlo ze-Electrode zingahlukaniswa zibe izigwedlo ezinkulu nezincane zama-electrode ezingakwazi ukwenza i-fibrillate kubo bobabili abadala kanye nengane ngokulandelanayo.
Okuphezulu nangaphezulu:
Kufika ku -360J ekukhethweni kwamandla, ezigulini ezinemikhawulo ephezulu ye-defibrillation efana ne-myocardial infarction, ukukhuluphala, i-impedance ephezulu, ukukhethwa kwamandla aphezulu kubonisa izinga eliphezulu lokuphumelela kwe-defibrillation.
I-Greater Impedance Range kusuka ku -20-300Ω , ilungele uhla olukhulu lweziguli.
Ukusebenza kahle okuphezulu ngobuchwepheshe be-waveform obuthuthukisiwe be-Biphasic Truncated Exponential (BTE) kanye nesinxephezelo se-impedance esizenzakalelayo.
Ilindile njengoba udinga ukubuyekezwa njengoba ucela:
Izinga elithembekile belilokhu lifuna abasebenzi be-COMEN R&D.Njengedivayisi yosizo lokuqala, i-defibrillator ivame ukusetshenziswa ezindaweni eziyingozi kakhulu, lapho ukwethembeka kwayo kugqanyiswa khona ezimeni ezihlukahlukene.
I-Anti- shock and anti- fall, iqinile futhi ihlala isikhathi eside.Ngokuvikela kwe-IPX4 Ingress, i-S5 igwema ukungena koketshezi futhi ingasetshenziswa endaweni engaphandle eyinkimbinkimbi. | Ibhethri ye-lithium enomthamo omkhulu, isekela ukushaja ngokushesha kuze kufike ezikhathini ezingu-210 zokukhishwa okukhulu, ukwanelisa izidingo zomtholampilo. | Ngomsebenzi wokuzihlola owenziwe ngesandla, ozenzakalelayo, wokuziqalisa, uqinisekisa uhlelo lokusebenza nganoma yisiphi isikhathi. |
Iphrinta eshisayo engu-50mm, amagagasi acacile futhi anembe kakhulu. | Sekela imizuzu engama-240 yesitoreji sokuqoshwa kwezwi se-AED, ukuqoshwa kwesiguli ngasinye kungagcinwa kuze kube yimizuzu engama-60. | Ukubuyekezwa kwemicimbi eminingi, okuthrendayo nokugcinwa kwedatha. |
Isixazululo senethiwekhi esisekelwe kulwazi:
Ihlinzeka ngesixazululo esibanzi sokuxhumana, esivumela abasebenzisi ukuthi bafinyelele ulwazi lwesiguli futhi bathuthukise ukusebenza kahle komsebenzi lapho kudingeka.
Ukusebenza komkhiqizo kuthembekile futhi impilo yayo yesevisi yinde.