| Ukutholakala: | |
|---|---|
| Ubuningi: | |
I-MCL2258
MECANMED
3-abahlaziyi be badlala -hematology abahlukene indima enkulu ekuhlolweni kwegazi kwansuku zonke. Babala futhi bahlukanise amaseli amhlophe egazi, amaseli abomvu egazi, nama-platelet, anikeze amalebhu imiphumela ethembekile ngokushesha. Lezi zihlaziyi zegazi zaselabhorethri zisebenzisa kokubili ubuchwepheshe bukagesi kanye ne-optical ukuze bathole izinombolo ezinembile zawo wonke amapharamitha egazi ayisisekelo. Lolu hlobo lwe-hematology analyzer lufaneleka kahle kumalebhu amancane naphakathi nendawo adinga ukusebenza okuqinile ngaphandle kokuhlupheka okuningi.
I-Th is advanced hematology analyzer ingasebenzisa amasampula angafika kwangu-60 ngehora. Inqubo izenzekelayo - isampula, i-dilution, imisebenzi - ngakho abasebenzi baselebhu bachitha isikhathi esincane belindile. Iphatha igazi eliphelele noma amasampula ahlanjululwe ngaphambilini, futhi izinyathelo eziningi zithatha nje ukucindezela inkinobho.
I-Labhorethri yokuhlaziya igazi ihlanganisa ukutholwa kukagesi kanye ne-colorimetric ukuze uthole imiphumela engaguquki kakhulu. Amasistimu okulawula ikhwalithi akhelwe ngaphakathi anokuqapha okuzenzakalelayo okungemuva aqinisekisa ukwethembeka emtholampilo.
Isihlaziyi se-hematology esinezingxenye ezi-3 silandelela ukuthi uyisebenzisa kangakanani i-reagent, igcina imfucuza iphansi, futhi ikhiphe ngokunemba kwangempela, ngenxa yamaphampu egiya. Amabhakhodi aqinisekisa ukuthi awuwasebenzisi ama-reagents aphelelwe yisikhathi - iqoqo ngalinye lifaniswa nedethi yokuphelelwa yisikhathi ngokuzenzakalelayo.
Ifaka isikrini esithintwayo sombala ongu-10.4-intshi nokugeleza komsebenzi okuqondisiwe. Izinqubo zokuhlanza ezizenzakalelayo zinciphisa ubunzima bokulungisa.
Lesi sihlaziyi se-hematology esinezingxenye ezi-3 sixhuma ngqo ezinhlelweni ze-HL7 ne-LIS, ngakho imiphumela yokuhlolwa ivunyelaniswa nezizindalwazi zesibhedlela ngesikhathi sangempela. Idatha ihamba ngazo zombili, futhi akudingekile ukuthi udideke ngokulayishwayo mathupha noma amaphepha.
Izingxenye eziningi ziyazihlanze, futhi i-analyzer isebenza kancane kancane kumazinga okushisa ahlukahlukene - ngokuyisisekelo, noma kuphi phakathi kuka-10 no-30°C. Lokho kusho ukuthi isikhathi esincane sokuphumula kanye nemiphumela enokwethenjelwa ngokuhamba kwesikhathi.
Ukusampula Okuzenzakalelayo Kwe-Hematology Analyzer
Isikrini sokuthinta sombala esingu-10.4-intshi se-Hematology Analyzer
Imodeli |
I-MCL2258 |
I-Histogram |
I-histogram ye-white cell cell (WBC). I-histogram ye- latelet (PLT) |
Hlola I tems |
I-WBC, LYM #, MID #, GR #, LYM%, MID%, GR%, RBC, HGB,HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW,PCT, P-LCC, P-LCR |
Okokusebenza |
60 amasampula / ihora |
Isampula T uhlobo |
P ulse igazi le -peripheralIgazi P kabusha igazi |
Igazi V olume |
I-10 uL yegazi le-venous kanye negazi le-peripheral, 20 uL |
Bonisa |
Isikrini se-LCD esingu-10'4 intshi se-HD ( Imiphumela yonke kanye nama-histograms kuboniswa esikrinini esifanayo ) |
Isitoreji |
Ukulondoloza okuzenzakalelayo, ubuningi bemiphumela yesampula engu-200,000 (kuhlanganise nolwazi lwesampula) |
Isixhumi esibonakalayo |
I-LAN RS232 I-HDMI 4 USB |
Ukunikezwa kwamandla kagesi |
100 ~ 240V |
Isisindo |
Isisindo esiphelele: mayelana ne-17kg Gross isisindo: mayelana 20kg |
Ivolumu |
womshini: 265 × 380420mmUsayizi Usayizi wephakheji: × 580545mm465 |
Ilungele umsebenzi wegazi ojwayelekile emitholampilo yeziguli zangaphandle—iwusizo ekuhlolweni okusheshayo nokuxilongwa komzuliswano wokuqala.
2. Amalabhorethri Esibhedlela Amancane kuya Kuphakathi
Ihambisana nezidingo zokuhlola zansuku zonke, iletha imiphumela esheshayo yamacala aphuthumayo navamile.
Usayizi wayo ohlangene nokusebenza okuthembekile kuhle emitholampilo ephathwayo nezindawo ezikude.
Iwusizo ekufundiseni amalebhu noma amaphrojekthi amancane ocwaningo adinga idatha ethembekile yegazi.
A1: Nakanjani. Icubungula amasampula angama-60 ngehora futhi ukulawulwa kwekhwalithi okwakhelwe ngaphakathi akuthathi ikhefu. Ngisho nalapho izinto ziba matasatasa, ibamba amapharamitha angukhiye (WBC, RBC, njll.) inganyakazi, igcina amanani e-CV engaphansi noma ngaphansi kuka-2.5%. Ukuqapha okuzenzakalelayo kumisa imiphumela ekukhukhuleni.
A2: Amaphampu egiya anembe ngokwedlulele - ehlela ku-0.01mL - futhi isistimu ibala ukusetshenziswa kwe-reagent ngesampula ngayinye, ukuze unciphise ukusetshenziswa okungadingekile. Ukulandelela ibhakhodi kumisa ama-reagents aphelelwe yisikhathi ukuthi angasheleli.
A3: Yebo, kuqondile. I-analyzer ikhuluma i-HL7 futhi inokuxhumana okujwayelekile (LAN/RS232), ukuze ukwazi ukuyisetha ngamasistimu amaningi e-LIS ngaphandle kwebhokisi—akukho khodi yangokwezifiso, azikho izindleko ezengeziwe.