| Ukutholakala: | |
|---|---|
| Ubuningi: | |
I-MCL1657
MeCan
Incazelo Yomkhiqizo:
I-MeCan MCL1657 5 Part Hematology Analyzer isebenzisa ubuchwepheshe be-laser scatter flow cytometry esezingeni eliphezulu ezingxenyeni ezi-5 ekubaleni okunembile kwe-WBC okuyizingxenye ezi-5. Ngesiteshi esizimele sokubala se-BASO nokuhambisana negazi eliphelele, igazi le-peripheral, namasampula egazi ahlanjululwe ngaphambilini, lesi sihlaziyi siletha imiphumela enembile nephumelelayo. Idizayinelwe amalabhorethri asebenza kahle kakhulu, icubungula amasampula afika kwangu-60 ngehora futhi ihlinzeka ngemingcele ebanzi yokuhlaziya okuningiliziwe.
Izici Eziyinhloko:
Ubuchwepheshe Ukubala Okuthuthukisiwe: I-cytometry yokugeleza kwe-laser ye-tri-angular iqinisekisa ukubala okunembile kwezingxenye ezi-5 ze-WBC.
Isiteshi Esizimele sokubala se-BASO: Isiteshi esizinikezele sokubala i-basophil ngokunembile.
Ukuhambelana Kwesampula Okuhlukahlukene: Ifanele igazi lonke, igazi le-peripheral, namasampuli egazi ahlanjululwe ngaphambilini.
Ukusebenza Okuphezulu: Iyakwazi ukucubungula amasampula afika kwangu-60 ngehora, alungele izindawo ezimatasa zaselabhorethri.
Amapharamitha Aphelele: Ihlinzeka ngamapharamitha angama-29, okuhlanganisa nemingcele yocwaningo emi-4, yokuhlaziya igazi elinemininingwane.
Isistimu Ye-Reagent Esebenzayo: Isebenzisa ama-reagents angu-3 anokulawula ikhwalithi yangempela (i-QC) nezikali zokusebenza okuthembekile.
Idatha Yezobuchwepheshe:
Ukubala Ubuchwepheshe: Tri-angular laser scatter flow cytometry
I-WBC Differential: Izingxenye ezi-5 nesiteshi esizimele sokubala se-BASO
Izinhlobo Zesampula: Igazi eliphelele, igazi le-peripheral, igazi elihlanjululwe ngaphambili
Ukukhiqiza: amasampula angama-60 ngehora
Amapharamitha: Amapharamitha angama-29 (kufaka phakathi amapharamitha ocwaningo ama-4)
I-Reagent System: Ama-reagent ama-3 ane-QC yoqobo nama-calibrator
Kungani Khetha i-MeCan MCL1657 5 Part Hematology Analyser?
I-MeCan 5 Part Hematology Analyzer igqama nge-cytometry yayo ethuthukisiwe ye-laser scatter cytometry engu-tri-angular kanye neshaneli yokubala ye-BASO ezimele, ehlinzeka ngokubala okunembayo nokuthembekile kwe-WBC okuyizingxenye ezi-5. Ikhono layo lokuphatha amasampula egazi ahlukahlukene kanye nokuphuma okuphezulu kwamasampula angama-60 ngehora kuyenza ibe ukukhetha okuhle kumalabhorethri agxile ekusebenzeni kahle nokunemba. Ngamapharamitha aphelele kanye nesistimu ye-reagent esebenzayo, iqinisekisa ukuhlaziywa kwegazi okunemininingwane nokuthembekile ngaso sonke isikhathi.
I-5 Part Hematology Analyzer yakhelwe ukuhlaziywa kwegazi okunembayo okuphezulu kusetshenziswa i-cytometry ethuthukisiwe ye-laser scatter cytometry ukuze uthole ukubala okunembile kwezingxenye ezi-5 ze-WBC. Ifaka isiteshi esizimele sokubala se-BASO futhi isekela igazi eliphelele, igazi le-peripheral, namasampula egazi ahlanjululwe ngaphambilini. Ngokuphuma kwamasampula angama-60 ngehora namapharamitha angama-29 (okuhlanganisa nemingcele yocwaningo emi-4), lesi sihlaziyi sinikeza ukuhlaziywa kwegazi okuphelele nokusebenza kahle. Uhlelo lusebenzisa ama-reagents angu-3 anokulawula ikhwalithi yasekuqaleni nama-calibrator, aqinisekisa imiphumela engaguquki nethembekile.