| Ukutholakala: | |
|---|---|
| Ubuningi: | |
MCL0698
MECANMED
Ekunakekelweni okuphuthumayo lapho imiphumela ebambezelekile ibeka engcupheni imiphumela yesiguli, i-MECANMED MCL0698 Portable Dry Blood Gas Analyzer iletha imiphumela enembe ngelebhu ngemizuzu engu-4±1 ngekhemikhali eyomile nobuchwepheshe be-microfluidic. Ihlanganisa amapharamitha angu-34 (isb., i-pH, ama-electrolyte) ngomklamo ongasindi (3.0±0.5 kg) kanye nokuhlola okusekela ibhethri okungu-≥60, okuqinisekisa ukwethembeka ezindaweni ezingazinzile ezifana nezilungiselelo ezikhawulelwe amandla noma ezinomswakama ophezulu.
Imiphumela Esheshayo Yezigcawu Eziphuthumayo : Ubuchwepheshe be-cartridge eyomile bomhlaziyi buvumela ukutholwa kwemizuzu emi-4, ukusika isikhathi sokuxilongwa ngo-50% ezimeni ezibucayi ngokuzilinganisa okuhlanganisiwe okuqinisekisa ukunemba ngokwamazinga e-ISO.
Ukuphatheka Kwezilungiselelo Ezinomkhawulo Wensiza : Ngedizayini engasindi nempilo yebhethri yamahora angu-24, isekela ukuhlolwa okuseceleni kombhede ezindaweni ezinamandla angathembeki noma izinga lokushisa elidlulele, elisebenza ngokwethembeka ku-10°C–31°C.
Ukugcinwa Kwezindleko Eziphansi Kwemitholampilo YaseGrassroots : Amagobolondo omile awadingi iketango elibandayo futhi anikeza isitoreji sezinga lokushisa legumbi (9–30°C, impilo yeshalofu yezinyanga ezingu-8), enciphisa izindleko zokusebenza kuyilapho ukulawulwa kwekhwalithi okumbaxambili kugcina ukunemba kwezisebenzi ezingezona uchwepheshe.
Ukunemba Kwepharamitha Eningi Kokuqapha kwe-ICU : Imboza amapharamitha angu-34 ngesikhathi esisodwa futhi igcina imiphumela yokuhlolwa engaphezu kuka-100,000, inikeza ukuqapha okuphelele ngaphandle kokuthatha amasampula okuphindaphindiwe, okunamamethrikhi okunemba njenge-pH ±0.04 eqinisekisa idatha ethembekile yezinqumo ezibalulekile.

Ipharamitha |
Inani |
Isikhathi sokutholwa |
4±1 amaminithi |
Isisindo |
3.0±0.5 kg (ngebhethri) |
Impilo Yebhethri |
≥60 ukuhlolwa, 24h okulindile |
ITemp Esebenzayo |
10°C–31°C |
Isitoreji Sedatha |
≥100,000 imiphumela yokuhlolwa kwesiguli |
Amapharamitha wokuhlola |
10 amapharamitha akaliwe (isb, i-pH, i-pCO₂, ama-electrolyte) kanye namapharamitha abaliwe angu-24 (isb., BE, SO₂) |
Isimiso Sokuhlola |
Izinzwa ze-Electrochemical ezinama-ion-selective technology kanye nobuchwepheshe be-microfluidic |
Test Consumables |
Amakhatriji okuhlola igesi yegazi elomile, agcinwe ekamelweni lokushisa (9–30°C, impilo yeshelufu yezinyanga ezingu-8) |
Umnyango Wezimo Eziphuthumayo : Ezimweni eziphuthumayo ezizwelayo ngesikhathi, ukuguqulwa komhlaziyi okuyimizuzu emi-4 kungena esikhundleni sokuhamba kancane kwelebhu emaphakathi, ngokuskena ibhakhodi kuqondisa ukufakwa kwedatha ngaphansi kwengcindezi.
Izilungiselelo Zezokwelapha Zeselula : Ezindaweni ezinokuphela kwamandla kagesi noma ezinomswakama ophezulu, ukusebenza kwebhethri ledivayisi kanye nomklamo oqinile kuqinisekisa ukuhlola okuqhubekayo ngaphandle kokuthembela kugridi yangaphandle.

Q: I-MECANMED yokuhlaziya igesi yegazi ephathekayo iqinisekisa kanjani ukusebenza okuzinzile ezindaweni ezinamandla angathembeki?
A: Ibhethri lisekela ukuhlola okungu-≥60, ngobubanzi obungu-10–31°C obusebenzayo kanye nekhemistri eyomile ukuze isetshenziswe ngaphandle kwegridi.
Q: Yini eyenza i-analyzer yegesi eyomile isebenze kalula kubasebenzi abanenzuzo ephezulu?
A: Isikrini esithintwayo esingu-8 intshi kanye nokuqeqeshwa kokusika ukuskena kwe-QR kube <amaminithi angu-30, ngokuzilinganisa ngokwakho ukuze kube nokunemba.
Q: Ingabe i-analyzer yegesi yegazi ingasekela ukuqapha kwepharamitha eminingi yeziguli ze-ICU?
A: Yebo, amapharamitha angama-34 kanye ne-QC ekabili iqinisekisa ukwethembeka, inciphisa izidingo zamasampula.