Ukubuka: 50 Umbhali: Isikhathi Sokushicilela Isihleli Sesayithi: 2024-02-04 Umsuka: Isayithi
Kulesi sihloko, sizokuhambisa ohambweni lokufakwa kwe-MeCan Medical a CT futhi we-MRI Umshini weklayenti eZambia.Kusukela ekuthathweni kwezinqumo kuya ekufakweni ngempumelelo kwe CT futhi Uhlelo lwe-MRI , sihlola imininingwane yokuhlangenwe nakho kwabo.Hlanganyela nathi njengoba sihlola ukuthi i-MeCan Medical iletha kanjani ubuchwepheshe bokunakekelwa kwezempilo obusezingeni eliphezulu, iguqula amakhono eklayenti okuxilonga.
Ukufakwa ngempumelelo kwe- CT futhi Umshini we-MRI uwumphumela wemizamo edidiyelwe yamaqembu asekhaya nawamazwe ngamazwe.I-MeCan Medical yengamele yonke inqubo, kusukela ekukhiqizweni kuye ekupakishweni nasekuthunyelweni, ukuqinisekisa ukuthi umkhiqizo ufika usesimweni esifanele.Ukufakwa, okuhlanganisa ukuqondiswa kwendawo, ukuqeqeshwa, kanye nokudluliselwa kweklayenti, kuphinde kubonise ukuzibophezela kwe-MeCan Medical ekuletheni ubuchwepheshe obuphambili be-CT ne-MRI.
I-MeCan Medical inake kakhulu ukufakwa ngokuqapha isimo sendawo yesibhedlela nokulandela eduze inqubo yokuthutha.Kwathathwa ukunakekelwa okukhulu ukuze kuqinisekiswe ukulethwa okuphephile komkhiqizo ngaphandle kokulimala.
Ngemva kokubeletha, i-MeCan Medical yaqapha ngokucophelela isimo sendawo yesibhedlela ukuze iqinisekise ukuthi iyahlangabezana nezidingo zenqubo yokufaka.
I-MeCan Medical igcine ukuxhumana okuqhubekayo kanye nokulandela umkhondo wenqubo yezokuthutha ukuze kuqinisekiswe ukufika ngesikhathi kwempahla lapho iya khona.
Lapho isiqukathi sifika lapho siya khona, amaqembu asekhaya nawamazwe ngamazwe asebenza ndawonye ukuze abhekane nanoma yikuphi ukukhathazeka kwamakhasimende, ehlose ukulethwa kwekhwalithi ephezulu nokushesha.
Enye yezinselelo ithimba lethu elihlangabezane nazo ngesikhathi kufakwa iklayenti lethu eZambia imishini ye-CT kanye ne-MRI yayibhekene nokulinganiselwa kwesisindo.Indawo yesikhungo iveze izingqinamba zesakhiwo ezidinga ukuthi sicabangele ngokucophelela inqubo yokufaka.
Ukuze sinqobe le nkinga, ithimba lethu lokufaka elinolwazi lihlole indawo yonke futhi lasebenzisana nonjiniyela bezakhiwo.Sakhe uhlelo olubandakanya ukuqinisa phansi ukuze kuhlangatshezwane nesisindo semishini ye-CT ne-MRI.Lokhu kwakuhilela ukufakwa kwezisekelo ezengeziwe zesakhiwo ukuze kuqinisekiswe ukuzinza nokuphepha kwezinto zokusebenza.
Lokhu kwakuhilela ukuzulazula ngokucophelela ekuthuthweni nasekungeneni kwemishini endaweni yokufaka, okwadala ubunzima obukhulu phakathi nenqubo yokuthutha.
Ukuze kubhekwane nalolu daba, ithimba lethu lanaka ngokucophelela imininingwane ukuze liqinisekise ukuthuthwa okuphephile kanye nesimo esihlanzekile semishini.Sisebenzise amathuluzi akhethekile namasu ukuze silayishe futhi sehlise ngokuphephile imishini ye-CT neye-MRI, sinciphise noma yimuphi umonakalo ongaba khona phakathi nokuphathwa.
Ukwengeza, sixhumane eduze neklayenti kanye nethimba lengqalasizinda yesikhungo ukuze sinqume izindawo zokufinyelela ezingcono kakhulu nezindlela zokungena kwemishini endaweni yokufaka.Sihlele ngokucophelela umzila, sicabangela noma yiziphi izithiyo ezingaba khona noma imikhawulo yendawo engase ithiye inqubo.
Kwa-MeCan Medical, siyakuqonda ukubaluleka kokuphepha uma kuziwa ezintweni eziwusizo zezokwelapha ezifana nemishini ye-MRI ne-CT.
Ngokusekelwe kulokho esikutholile, sibambisene nethimba lezokuphepha leklayenti ukuze siqinise izilawuli zokufinyelela futhi sithuthukise ukubhekwa kwendawo lapho kuzotholakala khona imishini ye-MRI ne-CT.
Ngokunaka imininingwane emelene nokwebiwa, sikwazile ukunciphisa ngempumelelo ingozi yokweba ngesikhathi sokuthenga nokufaka i-MRI ne-CT.
Ukufakwa ngempumelelo kwemishini ye-MRI kanye ne-CT esibhedlela sase-Zambia kwaba umphumela wemizamo ehlangene yamaqembu e-MeCan Medical asekhaya nawamazwe ngamazwe, kanye nokusebenzisana neklayenti.Lolu cwaningo lwesibonelo lubonisa ukubaluleka kokuhlela ngokucophelela, ukuxhumana okuqhubekayo, namakhono okuxazulula izinkinga ukuze kuzuzwe inqubo yokufaka engenazihibe.
I-MeCan Medical igcizelela ukubaluleka kokuxoxisana ngamanani namakhasimende, iqinisekisa ukuqhathaniswa okuzuzisayo kuzo zombili izinhlangothi.Lokhu kwakuhlanganisa izingxoxo nezingxoxo ezijulile neklayenti lethu laseZambia ukuze siqinisekise isivumelwano samanani esinobulungiswa nesincintisanayo sokufakwa nokugcinwa kokunakekelwa kwemishini ye-MRI kanye ne-CT.
Ukukhetha i-MeCan Medical: Lapho iklayenti lethu lase-Zambia linquma ukutshala imali ohlelweni lwe-MRI ne-CT, lenze ucwaningo olunzulu ukuze lithole umlingani omethembayo.Ngemva kokuqhathanisa izinketho ezihlukahlukene, bakhethe i-MeCan Medical ngedumela lethu njengomhlinzeki oholayo wemishini yezokwelapha ethuthukisiwe.Ukuzinikela kwethu kukhwalithi, ukwethembeka, kanye nesevisi kudlale indima enkulu enqubweni yabo yokuthatha izinqumo.
Ukubonisana Nokwenza Ngokwezifiso: Kwa-MeCan Medical, siyaqonda ukuthi zonke izidingo zeklayenti zihlukile.Ngeqembu lochwepheshe abanolwazi olunzulu, siqinisekise ukubonisana komuntu siqu ukuze siqonde izidingo ezithile zeklayenti lethu laseZambia.Ochwepheshe bethu basebenze eduze nabo, benikeza isiqondiso, futhi benza ngendlela oyifisayo izinhlelo ze-MRI ne-CT ngokufanele, beqinisekisa ukuthi bahlangabezana ngokuphelele nezidingo zabo zokuxilonga.
Ngemva kokuthenga ama-CTs nama-MRIs, ungakhohlwa ukuthenga imikhiqizo ehambisanayo ukuze ugweme noma yikuphi ukubambezeleka futhi uqinisekise ukufakwa okungenazihibe.Izibonelo zifaka ama-MRI Injection nezicabha zokuhola.Ngenxa yalokho, ukukhetha umhlinzeki wemishini yezokwelapha enendawo eyodwa efana ne-MeCan Medical ingakunikeza isisombululo esiphelele, ukuxazulula noma yikuphi ukukhathazeka ongase ube nakho mayelana nokuhambisana nokusebenziseka kwemishini.
LINGANISA ISIKHALA: Linganisa ngokunembile indawo etholakalayo lapho kuzofakwa khona i-MRI noma i-CT.Cabangela ubukhulu begumbi, ukuphakama kosilingi kanye nanoma yiziphi ezinye izithiyo zesikhala.
Cabangela usayizi wesistimu: Amamodeli ahlukene wezinhlelo ze-MRI kanye nama-CTs eza ngosayizi abahlukene, ngakho-ke kubalulekile ukukhetha isistimu elingana endaweni oyikhethile.Qiniseka ukuthi kunendawo eyanele yokuthi isiguli singene siphume futhi sizizwe sikhululekile ngesikhathi siskenwa.
Linganisa izidingo zamandla: Imishini ye-MRI kufanele ihlangabezane nezidingo ezithile zamandla.Qiniseka ukuthi ingqalasizinda kagesi yendawo yakho ingasekela uhlelo lwe-MRI olucabangayo.Kunconywa kakhulu ukubonisana nochwepheshe kagesi noma we-MRI.
Cabangela ukufakwa kwezinto: Cabangela ukufinyeleleka kwesayithi yokufaka.Ingabe umshini ungangena eminyango nasemaphasishi?Ingabe zikhona izithiyo noma imikhawulo yesakhiwo engase ithinte inqubo yokufaka?Linganisa lezi zici ukuze ugweme izimanga ngesikhathi sokufakwa.
Lapho ukhetha i-MRI, kuyatuseka ukuhlola indawo etholakalayo hhayi kuphela ohlelweni lwe-MRI kodwa futhi nezinto ezingase zibe khona zesikhathi esizayo, kuhlanganise nesithwebuli se-CT.Ngale ndlela, ungaqinisekisa ukuthi indawo yakho ihlomele kahle izinhlobonhlobo zezidingo zezithombe zezokwelapha.
Kungani ukhethe i-MRI ye-MeCan Medical?
Into | SIEMENS | I-FujiFilm (Hitachi) | GE | I-Neusoft | Mindray | Amazwana | |
I-MAGNETOM C | APERTO Lucent | Intengo ye-MR235 | Inkanyezi engu-0.35T | I-MagSense 360 | |||
/ | |||||||
Isistimu yezibuthe | / | ||||||
Uhlobo lwezibuthe | Unomphela | Unomphela | Unomphela | Unomphela | Unomphela | Unomphela | / |
Amandla enkundla | 0.38 T ± 5% | 0.35T | 0.4T | 0.3T | 0.35T | 0.36T | / |
Ukubonakala kukazibuthe | Umumo ka-C | Umumo ka-C | Uhlobo olugcwele - oluvulekile (i-C-shape) | Ikholomu Ekabili yangemuva | Umumo ka-C | Umumo ka-C | / |
I-GAP kaMazibuthe | 38.5cm ± 1cm | 41 cm | 38cm | 40 cm | 40 cm | / | |
Isisindo | 16.6T ± 1.5% | 16T | 14.8T | 17T | 17.2T | 18T | / |
I-engeli yokuvula evundlile | 320° | 270° | 320° | / | N/A | 320° | I-engeli yokuvula enkulu izonikeza umuzwa ongcono esigulini |
5 Inkundla ye-Gaussian fringe | X, Y, Z izikhombisi-ndlela ≤ 2.5m | 2.9m*3.1m*2.2m | / | / | X, Y, Z izikhombisi-ndlela ≤ 2.5m | X, Y, Z izikhombisi-ndlela ≤ 2.5m | / |
Shimming | I-Passive + Iyasebenza | I-Passive + Iyasebenza | I-Passive + Iyasebenza | I-Passive + Iyasebenza | Ungenzi lutho | I-Passive + Iyasebenza | / |
I-Homogeneity (VRMS) | 40cm DSV ≤ 2.0ppm | 36cm DSV 2.5ppm 20cm DSV 1.2ppm | 3.0 ppm @ 35 DSV | 40cm DSV 2.0ppm | 36cm DSV 1.8ppm | 40cm DSV 5ppm | I-homogeneity ephakeme isho ukuthi ungathola izithombe zekhwalithi ephezulu kalula, ikakhulukazi ukuskena umzimba kwe-FOV enkulu, ukuthwebula ukucindezelwa kwamafutha nezinye izinhlelo zokusebenza ezithuthukile. |
Isistimu ye-Gradient | / | / | / | / | / | / | / |
Uhlobo lokupholisa i-Gradient | Ukupholisa umoya | Ukupholisa amanzi | Ukupholisa umoya | Ukupholisa amanzi | Ukupholisa amanzi | Ukupholisa umoya | / |
Ubukhulu.ubukhulu | 28mT/m | 24mT/m | 25mT/m | 18mT/m | 26mT/m | 25mT/m | Igradient enamandla isho ukusebenza okuphezulu kwesivinini sokuskena nekhwalithi yesithombe. |
Ubukhulu.izinga lokubulala | 93T/m/s | 55T/m/s | 55T/m/s | 52T/m/s | 67T/m/s | 60T/m/s | |
Okuncane.isikhathi sokuvuka | 0.3ms | 0.44ms | 0.45ms | 0.35ms | 0.5ms | 0.41ms | |
imiz.Ubukhulu be-2D | 1.0mm | 1.6mm | / | 0.5mm | 0.2mm | 1.5mm | / |
imiz.Ubukhulu be-3D | 0.1mm | 0.05mm | 0.04mm | 0.1mm | 0.1mm | 0.2mm | / |
Ubukhulu.I-FOV | 400mm | 400mm | 350mm | 400mm | 400mm | 400mm | / |
Ilandelanisa amapharamitha | Okuncane.TE (SE) 5ms | Okuncane.TE (SE) 5.9ms | / | Okuncane.TE 1.23ms Okuncane.TR 3.3ms | Okuncane.TE 1.8ms Okuncane.TR 3.7ms | Okuncane.TE 3ms Okuncane.TR 8ms | / |
Isistimu ye-RF | / | / | / | / | / | / | |
I-RF amplifier Max.amandla | 6 kw | 2.5 kW | 5 kw | 6 kw | 5 kw | 6 kw | Ukukhipha amandla aphezulu kusho ukusebenza okuphezulu kokuskena. |
Inani leziteshi | 4 | 4 | / | 2 noma 4 | 4 | 2 noma 4 | |
Ithola Umkhawulokudonsa | 1.25MHz | 800 kHz | / | / | / | / | Umkhawulokudonsa ophezulu uhlinzeka nge-SNR ephezulu yezithombe |
Chofoza isithombe noma isixhumanisi ukuze uthole imininingwane:
https://www.mecanmedical.com/china-open-mri-machine-supplier-mecan-medical.html
Kungani ukhethe i-MeCan Medical's CT Scan?
INTO | I-SOMATOM Definition Edge | Revolution Maxima | |
Amapharamitha amakhulu | I-Definition Edge | Revolution Maxima | |
Isithombe somkhiqizo | |||
Umthamo wokushisa weshubhu | 7.5MHU | 6.0MHU | 7.0MHU |
Amandla e-generator | 80kW | 55kw | 72kw |
mA ububanzi | 10-800mA | 20-345mA | 10-600mA |
kV izinyathelo | 70-140kV | 80-130kV | 80-140kV |
Izingcezu | 128 izingcezu | 128 izingcezu | 128 izingcezu |
Isikhathi sokuzungeza | 0.286s | 0.28s | 0.7/0.35*s |
Ukumbozwa komtshina | 40mm | 38.4mm | 40mm |
Ukulungiswa kwendawo | 21lp/cm@0%MTF | 17.5lp/cm@0%MTF | 18.3lp/cm@0%MTF |
Amandla e-generator | 80kW | 55kw | / |
I-Tube Heat Amandla | 7.5MHU | 6.0MHU | 7.0MHU |
Ukukhipha ukushisa | 1386kHU/min | 810kHU/min | / |
Umthamo wesiguli ngosuku | 115-125 | 80-90 | / |
mA ububanzi | 10-800mA | 20-345mA | 10-600mA |
kV izinyathelo | 70-140kV | 80-130kV | 80-140kV |
Chofoza isithombe noma isixhumanisi ukuze uthole imininingwane:
www.mecanmedical.com/efficient-ct-scan-brain-machines.html
Into | ||||
Imikhiqizo ehambisanayo | I-MRI Contrast Injection for Precision Imaging | I-CT Power Injection ye-Precision Imaging
| Iminyango yokuhola yegumbi le-CT
| Iwindi lengilazi eliholayo legumbi le-CT
|
Sengiphetha, i-MeCan Medical inikeza imishini ye-MRI ethuthukisiwe nemikhiqizo ehambisanayo.Uma udinga usizo lokufakwa kwemishini emikhulu yezokwelapha, efana nalokho esikufezile e-Zambia, ungangabazi ukuxhumana ne-MeCan Medical - umphakeli othembekile wemishini yezokwelapha onolwazi nokwesekwa ukuze ahlangabezane nezidingo zakho ezithile. Xhumana nathi ukuze uthole ukwesekwa okukhethekile ngezidingo zakho zemishini yezokwelapha.
I-One-Stop Solution Provider