MeCan Medical High Quality Color LCD Display Multi-Parameter Portable Patient Monitor Manufacturer - Guangzhou MeCan Medical Limited,MeCan offer professional service,our team is well-tained, we are very professional and we will provide the best service to you.
Quantity: | |
---|---|
12.1 Inch LCD Multi Parameter Patient Monitor
Features
1. 12.1" color TFT LCD screen, resolution: 800*600
2. 5 kinds of interfaces: Standard/Big font/6-lead ECG/Trend gragh/OxyCRG
3. Maximum 8-channel waveforms display, the waveform color can be defined by user (7 colors)
4. 96-hour storage and review of trend graphic gram and table, 400 groups NIBP data, 1800 alarm events
5. ST and arrhythmia analysis, pacemaker analysis, drug dose calculation
6. Anti - defibrillation design
7. NIBP over pressure protection
8. Plug -in rechargeable battery, AC/DC available
9. Support wire or wireless network
Benefits
1. 6 Standard parameters: ECG, RESP, NIBP, SPO2, 2~TEMP, PR/HR.
2. 12.1"high resolution color TFT LCD display.
3. Real time S~T segment analysis, pace~maker detection.
4. Indication of Incorrect manipulation and malfunction analysis.
5. Patient info input management function
6. Multi~lead ECG waveforms display in phase.
7. Large volume of tabular and graphic trends information storage and easy to recall.
8. Capture dynamic waveforms.
9. Efficient resistance to interference of defibrillator and HF knife.
10. UP to 2 hours working capacity of built~in rechargeable battery.
11. Unique accessory management cabinet.
12. Networking capacity.
13. Option: IBP, ETCO2 and 2~IBP.
NIBP | Method:Oscillometry Modes:Manual/Auto/Comtinuous Auto measure time:Adjustable Measurement range:10-270mmHg |
ECG | Lead mode: 3-lead or 5-lead Lead selection: I;II;III,avR;avF;V Heart rate range: Adult:15-300bpm; Pediatric/Neonatal:15-300bpm ECG waveform: 2 channals Accuracy: ±1 bpm or ±1%,which is greater S-T segment detection; measurement range: 2.0mv~2.0mv Alarm:Yes,audible and visual alarm,alarm events review |
SPO2 | Measurement range:0-100% Accuracy:70-100%,±2%,0-69%,upspecified Auto measure time:Adjustable |
Pulse Rate | Range:20-254bpm Accuracy: ±3bpm |
Respiration | Method:RA-LL impedance Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm Apnca alarm:Yes |
Temperature | Range:0-500 Accuracy: ± 0.10 Channal:Dual-channel |
12.1 Inch LCD Multi Parameter Patient Monitor
Features
1. 12.1" color TFT LCD screen, resolution: 800*600
2. 5 kinds of interfaces: Standard/Big font/6-lead ECG/Trend gragh/OxyCRG
3. Maximum 8-channel waveforms display, the waveform color can be defined by user (7 colors)
4. 96-hour storage and review of trend graphic gram and table, 400 groups NIBP data, 1800 alarm events
5. ST and arrhythmia analysis, pacemaker analysis, drug dose calculation
6. Anti - defibrillation design
7. NIBP over pressure protection
8. Plug -in rechargeable battery, AC/DC available
9. Support wire or wireless network
Benefits
1. 6 Standard parameters: ECG, RESP, NIBP, SPO2, 2~TEMP, PR/HR.
2. 12.1"high resolution color TFT LCD display.
3. Real time S~T segment analysis, pace~maker detection.
4. Indication of Incorrect manipulation and malfunction analysis.
5. Patient info input management function
6. Multi~lead ECG waveforms display in phase.
7. Large volume of tabular and graphic trends information storage and easy to recall.
8. Capture dynamic waveforms.
9. Efficient resistance to interference of defibrillator and HF knife.
10. UP to 2 hours working capacity of built~in rechargeable battery.
11. Unique accessory management cabinet.
12. Networking capacity.
13. Option: IBP, ETCO2 and 2~IBP.
NIBP | Method:Oscillometry Modes:Manual/Auto/Comtinuous Auto measure time:Adjustable Measurement range:10-270mmHg |
ECG | Lead mode: 3-lead or 5-lead Lead selection: I;II;III,avR;avF;V Heart rate range: Adult:15-300bpm; Pediatric/Neonatal:15-300bpm ECG waveform: 2 channals Accuracy: ±1 bpm or ±1%,which is greater S-T segment detection; measurement range: 2.0mv~2.0mv Alarm:Yes,audible and visual alarm,alarm events review |
SPO2 | Measurement range:0-100% Accuracy:70-100%,±2%,0-69%,upspecified Auto measure time:Adjustable |
Pulse Rate | Range:20-254bpm Accuracy: ±3bpm |
Respiration | Method:RA-LL impedance Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm Apnca alarm:Yes |
Temperature | Range:0-500 Accuracy: ± 0.10 Channal:Dual-channel |