MECAN MEDIKU L-aħjar kwalità tal-fabbrika tal-analizzatur tal-gass tad-demm, kull tagħmir minn MECAN jgħaddi minn spezzjoni ta 'kwalità stretta, u r-rendiment mgħoddi finali huwa 100%, aħna professjonali ħafna u aħna nipprovdu l-aħjar servizz lilek.
Kwantità: | |
---|---|
Analizzatur tal-gass tad-demm mediku
Speċifikazzjoni
Tip ta 'kampjun
Demm sħiħ, serum, plażma, djalizzata, CSF
Isem tal-mudell u oġġetti tat-test
BG-800 (PH / PCO2 / PO2 / K + / NA + / CI- / Ca ++ / HCT)
BG-800A (PH / PCO2 / PO2 / HCT)
BG-800B (PH / PCO2 / PO2 / K + / NA + / CI- / HCT)
BG-800E (PH / PCO2 / PO2 / K + / Na + / CI- / Ca ++ / HCT / Glu / LAC)
BG-800Q (PH / PCO2 / PO2 / K + / Na + / CI- / Ca ++ / HCT Auto QC)
BG-800AQ (PH / PCO2 / PO2 / HCT AUTO QC)
BG-800BQ (PH / PCO2 / PO2 / K + / NA + / CI- / HCT AUTO QC)
Parametri mkejla
Analite | Firxa tal-kejl | Unità |
pH (ch) | 6.000-9.000 | |
PCO2 | 1.607-26.67 | KPA |
8.0-200.0 | mmhg | |
PO2 | 0-106.7 | KPA |
0-800.0 | mmhg | |
K | 0.5-15.0 | mmol / l |
Na + | 20.0-200.0 | mmol / l |
Ċokon | 20.0-200.0 | mmol / l |
Ca ++ | 0.3-5.0 | mmol / l |
Hct | 12.0-65.0 | Biżżejjed |
Bp | 500-800 | mmhg |
Glukożju | 1.1-66.7 | Mmol / l |
Lactate | 0.4-30.0 | Mmol / l |
Ambjent tax-xogħol
Temperatura tax-xogħol: 15 ℃ ~ 30 ℃
Ambjent tal-Ħażna: 5 ℃ ~ 45 ℃
Provvista ta 'enerġija: 100-240V ~ ± 10 &, 50/60 ± 1Hz
Qawwa: 150VA
Dimensjoni (tul * wisa '* għoli): 420mm × 623mm × 410mm
Piż: 25kg
Karatteristiċi ewlenin
Parametri multi-kombinazzjoni
Elettrodi bla manutenzjoni magħmulin minnha nnifisha
Kemm għas-siringi u l-kapillari
35ul għal kapillari, 95ul għal demm sħiħ
1 min mill-aspirazzjoni li tirriżulta
Sistema ta 'fluwidu li ddum
Disinn All-in-One Calibrate Cartridge
Allarm u residwu ta 'skadenza tal-iskartoċċ
Reaġenti u Kampjun ta 'Saħħan minn qabel
Skartoċċ Auto QC mhux obbligatorju b'livell H / M / L
Ħażna tad-Dejta> 5,000
Touch screen ikkulurit b'riżoluzzjoni għolja
Interfaċċa ta 'operazzjoni ta' ħbiberija
Detettur tal-bniedem infra-aħmar
Interfaċċa rikka għall-immaniġġjar tad-dejta
Backup tal-batterija
Stampatur termali build-in
Ġestjoni konvenjenti tas-sistema tal-bar-code
Spiża ekonomika għal kull test
L-immaniġġjar tal-kwalità ta 'MECAN Medical huwa ta' importanza ta '100%. Mill-għażla tal-materja prima għall-prodotti lesti, kull pass ta 'spezzjoni jitmexxa strettament u segwit biex jissodisfa r-regolamentazzjoni tar-rigali u l-artiġjanat.
Analizzatur tal-gass tad-demm mediku
Speċifikazzjoni
Tip ta 'kampjun
Demm sħiħ, serum, plażma, djalizzata, CSF
Isem tal-mudell u oġġetti tat-test
BG-800 (PH / PCO2 / PO2 / K + / NA + / CI- / Ca ++ / HCT)
BG-800A (PH / PCO2 / PO2 / HCT)
BG-800B (PH / PCO2 / PO2 / K + / NA + / CI- / HCT)
BG-800E (PH / PCO2 / PO2 / K + / Na + / CI- / Ca ++ / HCT / Glu / LAC)
BG-800Q (PH / PCO2 / PO2 / K + / Na + / CI- / Ca ++ / HCT Auto QC)
BG-800AQ (PH / PCO2 / PO2 / HCT AUTO QC)
BG-800BQ (PH / PCO2 / PO2 / K + / NA + / CI- / HCT AUTO QC)
Parametri mkejla
Analite | Firxa tal-kejl | Unità |
pH (ch) | 6.000-9.000 | |
PCO2 | 1.607-26.67 | KPA |
8.0-200.0 | mmhg | |
PO2 | 0-106.7 | KPA |
0-800.0 | mmhg | |
K | 0.5-15.0 | mmol / l |
Na + | 20.0-200.0 | mmol / l |
Ċokon | 20.0-200.0 | mmol / l |
Ca ++ | 0.3-5.0 | mmol / l |
Hct | 12.0-65.0 | Biżżejjed |
Bp | 500-800 | mmhg |
Glukożju | 1.1-66.7 | Mmol / l |
Lactate | 0.4-30.0 | Mmol / l |
Ambjent tax-xogħol
Temperatura tax-xogħol: 15 ℃ ~ 30 ℃
Ambjent tal-Ħażna: 5 ℃ ~ 45 ℃
Provvista ta 'enerġija: 100-240V ~ ± 10 &, 50/60 ± 1Hz
Qawwa: 150VA
Dimensjoni (tul * wisa '* għoli): 420mm × 623mm × 410mm
Piż: 25kg
Karatteristiċi ewlenin
Parametri multi-kombinazzjoni
Elettrodi bla manutenzjoni magħmulin minnha nnifisha
Kemm għas-siringi u l-kapillari
35ul għal kapillari, 95ul għal demm sħiħ
1 min mill-aspirazzjoni li tirriżulta
Sistema ta 'fluwidu li ddum
Disinn All-in-One Calibrate Cartridge
Allarm u residwu ta 'skadenza tal-iskartoċċ
Reaġenti u Kampjun ta 'Saħħan minn qabel
Skartoċċ Auto QC mhux obbligatorju b'livell H / M / L
Ħażna tad-Dejta> 5,000
Touch screen ikkulurit b'riżoluzzjoni għolja
Interfaċċa ta 'operazzjoni ta' ħbiberija
Detettur tal-bniedem infra-aħmar
Interfaċċa rikka għall-immaniġġjar tad-dejta
Backup tal-batterija
Stampatur termali build-in
Ġestjoni konvenjenti tas-sistema tal-bar-code
Spiża ekonomika għal kull test