I-digital radiography kanye nohlelo lwe-fluoroscopy luhlanganisa i-X-ray radiography evamile nesithombe sesikhathi sangempela esishukumisayo endaweni eyodwa. Idizayinelwe iminyango ye-radiology eyenza izivivinyo ezijwayelekile kanye nezifundo ze-fluoroscopic nezithuthukiswe ngokungafani.
I- MCI0043 Dynamic Digital Radiography & Fluoroscopy System ihlanganisa i-digital radiography, i-digital fluoroscopy, i-angiography yedijithali kanye ne-digital spot imaging . Umtshina waso omkhulu wephaneli yephaneli eyisicaba sisekela kokubili ukutholwa kwesithombe esimile nesikhathi sangempela, okuvumela ukugeleza komsebenzi okuhlukile kokuhlolwa ukuthi kuqedwe kusistimu efanayo.
Uhlelo futhi luhlinzeka ngokuma kwemishini okuguquguqukayo kwezifunda ezahlukene ze-anatomical kanye nezikhundla zokuhlolwa. Indawo yokusebenza edidiyelwe isekela ukutholwa kwezithombe, ukucutshungulwa kwangemuva, ukudluliswa kanye nokubika . Imisebenzi ongayikhetha efana ne -AEC, ukuqapha kwe-DAP nokuthungwa kwesithombe kunganezelwa ekugelezeni komsebenzi okuhlukile kokuhlolwa.
I-MCI0043 isekela uhla olubanzi lokuhlolwa kwe-radiographic kanye ne-fluoroscopic kuyo yonke i-radiology evamile kanye neminyango yomtholampilo ehlobene.
Isicelo somtholampilo |
Ukusetshenziswa Okuvamile |
I-General Digital Radioography |
I-radiography evamile yesifuba, umgogodla, i-pelvis, imikhawulo kanye nezinye izifunda ze-anatomical |
I-Digital Fluoroscopy |
Ukuhlolwa okuguquguqukayo kwesikhathi sangempela kwesifuba, isisu nezinye izindawo ze-anatomical |
Izifundo Zokuqhathanisa Zamathumbu |
I-Esophagography, umehluko ongenhla we-gastrointestinal kanye nezinye izivivinyo zamathumbu |
I-Urological Imaging |
Ukuhlolwa kwe-Fluoroscopic nokuqhathanisa okufana ne-IVP kanye nezifundo zepheshana lomchamo ezihlobene |
I-Gynecological Imaging |
Izinqubo zokuqhathanisa ne-fluoroscopic ezifana ne-hysterosalpingography |
I-Digital Spot Imaging |
Ukutholwa kwesithombe sendawo enencazelo ephezulu ngesikhathi sokubuka okuguquguqukayo noma ukudlalwa kwesithombe. |
I-Orthopedic Imaging |
Ukuthwebula okujwayelekile kwamathambo kanye ne-radiography yendawo ekhethekile |
Ukufanekisa Ubude Obude |
Isithombe se-panoramic somgogodla ogcwele nesitho esigcwele esingaphansi uma umsebenzi wokuthunga isithombe ongawukhetha ulungiswa. |
Uhlelo lusebenzisa i -84 kW ijeneretha ye-X-ray yemvamisa ephezulu ene- 550 kHz inverter frequency . I-Radiographic okukhiphayo ihlanganisa 40–150 kV neshubhu current kusuka ku -10–1000 mA . I-Fluoroscopy isebenza ukusuka ku -40–125 kV , enezigaba zamanje ezihlukene ze -fluoroscopy eqhubekayo ne-pulsed.
I-Lateral Cervical Spine
Isifuba
Umehluko Wesisu
Isisu nePelvis
Umtshina omkhulu wephaneli yesicaba eguquguqukayo engu-427 × 427 mm uhlinzeka ngo- 3072 × 3072 pixel matrix , 139 μm pixel pitch kanye nokuguqulwa kwe-16-bit A/D . Umtshina usekela ukutholwa okuguquguqukayo okufika ku-30 fps ukuze uthole ukubonwa kwe-fluoroscopic ngesikhathi sangempela kanye ne-static radiographic imaging.
Indawo esebenzayo engu-427 × 427 mm inikeza inkambu ebanzi yokubuka kokubili kwesithombe esimile nesiguquguqukayo.
Lolu hlelo luhlanganisa i-digital radiography, i-digital fluoroscopy, i-digital angiography kanye ne-digital spot imaging . Phakathi nokubuka okuguquguqukayo noma ukudlalwa kwesithombe, izithombe zezindawo ezinencazelo ephezulu zingashuthwa ukuze kuhlolwe eduze izindawo ezikhethiwe.
Uhlelo luhlinzeka ngokunyakaza kwemishini okuguquguqukayo ukusekela izikhundla ezihlukene zokuhlolwa kanye nezifunda ze-anatomical.
l I-Tube Column Swing
Ikholomu yeshubhu ye-X-ray ingashwiba isuka ku --45° iye ku-+45° , inikeze ukuguquguquka okwengeziwe kokuma kokuhlolwa kwezifunda ezihlukahlukene ze-anatomical.
l ±90° Ukuzungezisa Ithebula
Ithebula lokuhlola lingakwazi ukuzungeza ukusuka ku --90° ukuya ku-+90° , okuvumela isistimu ukuthi ibambe kokubili ukuma kwesithombe okuvundlile nokuqondile.
l I-SID Eguquguqukayo
Ibanga lomthombo ukuya esithombeni (SID) lingalungiswa lisuka ku -1000 liye ku-1800 mm , linikeze ukuguquguquka okukhulu kwezivivinyo ze-radiographic ezahlukene.
l I -Flexible Lateral Movement
Umtshina usekela ukunyakaza kwe-lateral okungu-320 mm , okuvumela inkambu yesithombe ukuthi ibekwe kabusha ezindaweni ezihlukahlukene ze-anatomical ngaphandle kokubeka kabusha isiguli njalo.
I -collimator kagesi ezenzakalelayo ivumela inkambu yokucabanga ukuthi ilungiswe ngokusho kokuhlolwa okukhethiwe kanye nesimo somzimba. Lokhu kusiza ukwenza lula ukuma futhi kunciphisa isidingo sokulungiswa okuphindaphindiwe kwenkundla ye-beam.
Isistimu ifakwe amagridi amabili asondelene kakhulu , angasuswa uma ukuthwebula isithombe okungenamagridi kuyadingeka ekuhlolweni okusebenzayo kwethamo eliphansi.
Indawo yokusebenza ihlanganisa ukubhaliswa kwesiguli, ukulawula ukuchayeka, ukutholwa kwezithombe, ukucutshungulwa kwezithombe, ukudluliswa kanye nokubika . Amathuluzi okucubungula isithombe ahlanganisa ukuthuthukisa isithombe, ububanzi bewindi nokulungiswa kwezinga, ukunqampuna kwesithombe neminye imisebenzi yokucubungula.
Ngokuxhunywa kwesistimu, isixhumi esibonakalayo se-DICOM 3.0 sisekela ukuhlanganiswa nokugeleza kokusebenza kwesithombe sezokwelapha okuhambisanayo.
I-MCI0043 ingalungiselelwa ngemisebenzi eminingana yokuzikhethela. I-AEC ilawula ngokuzenzakalelayo isikhathi sokuchayeka ngokwemibandela yokuhlolwa. Ukuqapha kwe-DAP kuqopha ulwazi lomthamo wokuhlolwa, kuyilapho ukuthungwa kwesithombe kusekela ukuthwebula izithombe komgogodla ogcwele noma izitho ezingezansi. Ukucushwa okungakhethwa kukho futhi kufaka indawo yokusebenza yesikrini esithintwayo se-LCD kanye nekhonsoli ekhethekile yokuhlinza/eseduze.
Isigaba |
Ipharamitha |
Ukucaciswa |
Ukunikezwa kwamandla kagesi |
Amandla kagesi |
380 V ±38 V |
Imvamisa |
50 Hz ±10 Hz |
|
Amandla |
≥125 kVA |
|
Ukumelana Kwangaphakathi |
≤0.17 Ω |
|
I-X-ray Generator |
Amandla |
84kw |
I-Inverter Frequency |
550 kHz |
|
I-Radiography Tube Voltage |
40–150 kV |
|
I-Radiography Tube Yamanje |
10–1000 mA |
|
Isikhathi sokuchayeka |
1–10000 ms |
|
I-radiography mAs |
0.1–1000 mAs |
|
I-Fluoroscopy Tube Voltage |
40–125 kV |
|
I-Fluoroscopy Eqhubekayo Yamanje |
0.5–10 mA |
|
I-Pulsed Fluoroscopy Yamanje |
5–20 mA |
|
X-ray Tube |
I-Focal Spot |
0.6 mm / 1.2 mm |
Amandla Okushisa e-Anode |
420 kJ / 600 kHU |
|
Isivinini se-Anode |
9700 rpm ku-180 Hz / 2700 rpm ku-50 Hz |
|
I-Engeli eqondiwe |
12° |
|
I-Dynamic Flat Panel Detector |
Indawo Esebenzayo |
427 × 427 mm |
I-Pixel Matrix |
3072 × 3072 |
|
I-Pixel Pitch |
awu 139m |
|
Ukuguqulwa kwe-A/D |
16 bit |
|
Ukulungiswa Okukhawulelwe |
≥3.7 lp/mm |
|
Ibanga lamandla |
40–150 kVp |
|
Ukuthola Okunamandla |
Kufika ku-30 fps |
|
I-Collimator |
Buka Ukukhanya |
I-LED |
Ukukhanya |
> 100 lux |
|
Isikhathi Sokukhanya Esibonakalayo |
5–45 s iyalungiseka |
|
Ukuhlunga |
≥1 mm Al |
|
Mechanical Movement |
Ukuzungezisa Kwethebula Okuqondile |
+90° kuya ku-90° |
Ukunyakaza Okuqondile |
1300 mm |
|
Ibanga Lokuphakamisa Itafula ukuya Phansi (Ongakukhetha) |
550-1350 mm |
|
I-Lateral Movement |
320 mm |
|
I-SID |
1000-1800 mm |
|
I-Tube Swing |
+45° kuya ku-45° |
|
Ukuxhumana |
Isixhumi esibonakalayo |
I-DICOM 3.0 |
Imisebenzi Engazikhethela |
I-AEC |
Ongakukhetha |
Ukuqapha kwe-DAP |
Ongakukhetha |
|
Ukuthunga Isithombe |
Ongakukhetha |
|
Isiteshi sokusebenza se-LCD sesikrini sokuthinta |
Ongakukhetha |
|
I-Specialized Surgical / Proximity Console |
Ongakukhetha |