IMINININGWANE YOMKHIQIZO
Ulapha: Ikhaya » Imikhiqizo » Umshini we-X-Ray » 84kW Umshini we-X-ray ongashintshi 1000mA Digital Radiography & Fluoroscopy System

iyalayisha

84kW 1000mA Digital Radiography & Fluoroscopy System

I-MCI0043 iyi-84kW, 1000mA digital radiography kanye nesistimu ye-fluoroscopy ehlanganisa izithombe eziguqukayo ezifika ku-30 ​​fps, ukuma okuguquguqukayo kwe-multi-dimensional kanye nokuxhumana kwe-DICOM 3.0.
Ukutholakala:
Ubuningi:
inkinobho yokwabelana ye-facebook
inkinobho yokwabelana ye-twitter
inkinobho yokwabelana ngomugqa
inkinobho yokwabelana ye-wechat
inkinobho yokwabelana ye-linkedin
inkinobho yokwabelana ye-pinterest
inkinobho yokwabelana ye-whatsapp
yabelana ngale nkinobho yokwabelana
  • I-MCI0043

  • MECANMED

Uhlolojikelele Lomkhiqizo

 

I-digital radiography kanye nohlelo lwe-fluoroscopy luhlanganisa i-X-ray radiography evamile nesithombe sesikhathi sangempela esishukumisayo endaweni eyodwa. Idizayinelwe iminyango ye-radiology eyenza izivivinyo ezijwayelekile kanye nezifundo ze-fluoroscopic nezithuthukiswe ngokungafani.

 

I- MCI0043 Dynamic Digital Radiography & Fluoroscopy System ihlanganisa i-digital radiography, i-digital fluoroscopy, i-angiography yedijithali kanye ne-digital spot imaging . Umtshina waso omkhulu wephaneli yephaneli eyisicaba sisekela kokubili ukutholwa kwesithombe esimile nesikhathi sangempela, okuvumela ukugeleza komsebenzi okuhlukile kokuhlolwa ukuthi kuqedwe kusistimu efanayo.

 

Uhlelo futhi luhlinzeka ngokuma kwemishini okuguquguqukayo kwezifunda ezahlukene ze-anatomical kanye nezikhundla zokuhlolwa. Indawo yokusebenza edidiyelwe isekela ukutholwa kwezithombe, ukucutshungulwa kwangemuva, ukudluliswa kanye nokubika . Imisebenzi ongayikhetha efana ne -AEC, ukuqapha kwe-DAP nokuthungwa kwesithombe kunganezelwa ekugelezeni komsebenzi okuhlukile kokuhlolwa.

 

Izicelo Zomtholampilo

 

I-MCI0043 isekela uhla olubanzi lokuhlolwa kwe-radiographic kanye ne-fluoroscopic kuyo yonke i-radiology evamile kanye neminyango yomtholampilo ehlobene.

 

Isicelo somtholampilo

Ukusetshenziswa Okuvamile

I-General Digital Radioography

I-radiography evamile yesifuba, umgogodla, i-pelvis, imikhawulo kanye nezinye izifunda ze-anatomical

I-Digital Fluoroscopy

Ukuhlolwa okuguquguqukayo kwesikhathi sangempela kwesifuba, isisu nezinye izindawo ze-anatomical

Izifundo Zokuqhathanisa Zamathumbu

I-Esophagography, umehluko ongenhla we-gastrointestinal kanye nezinye izivivinyo zamathumbu

I-Urological Imaging

Ukuhlolwa kwe-Fluoroscopic nokuqhathanisa okufana ne-IVP kanye nezifundo zepheshana lomchamo ezihlobene

I-Gynecological Imaging

Izinqubo zokuqhathanisa ne-fluoroscopic ezifana ne-hysterosalpingography

I-Digital Spot Imaging

Ukutholwa kwesithombe sendawo enencazelo ephezulu ngesikhathi sokubuka okuguquguqukayo noma ukudlalwa kwesithombe.

I-Orthopedic Imaging

Ukuthwebula okujwayelekile kwamathambo kanye ne-radiography yendawo ekhethekile

Ukufanekisa Ubude Obude

Isithombe se-panoramic somgogodla ogcwele nesitho esigcwele esingaphansi uma umsebenzi wokuthunga isithombe ongawukhetha ulungiswa.

 

Izici ezibalulekile

 

1. I-High-Power Generator ye-Radiography ne-Fluoroscopy

 

Uhlelo lusebenzisa i -84 kW ijeneretha ye-X-ray yemvamisa ephezulu ene- 550 kHz inverter frequency . I-Radiographic okukhiphayo ihlanganisa 40–150 kV neshubhu current kusuka ku -10–1000 mA . I-Fluoroscopy isebenza ukusuka ku -40–125 kV , enezigaba zamanje ezihlukene ze -fluoroscopy eqhubekayo ne-pulsed.



Isithombe se-X-ray somgogodla womlomo wesibeletho esibonisa izakhiwo zamathambo ezicacile ku-radiography yedijithali.

I-Lateral Cervical Spine

Isithombe se-X-ray sesifuba sangaphambili esibonisa amaphaphu, izimbambo kanye nezakhiwo ze-thoracic ku-radiography yedijithali.

Isifuba

Isithombe se-X-ray sokungafani sesisu esibonisa i-anatomy yamathumbu phakathi nokuhlolwa okuhlukile.

Umehluko Wesisu

Isithombe se-X-ray sesisu sangaphambili ne-pelvis esibonisa i-lumbar spine, i-pelvic nezakhiwo zesisu.

Isisu nePelvis



2. 17' × 17' Isitholi Sephaneli Eyisicaba Esinamandla

 

Umtshina omkhulu wephaneli yesicaba eguquguqukayo engu-427 × 427 mm uhlinzeka ngo- 3072 × 3072 pixel matrix , 139 μm pixel pitch kanye nokuguqulwa kwe-16-bit A/D . Umtshina usekela ukutholwa okuguquguqukayo okufika ku-30 ​​fps ukuze uthole ukubonwa kwe-fluoroscopic ngesikhathi sangempela kanye ne-static radiographic imaging.

 

Indawo esebenzayo engu-427 × 427 mm inikeza inkambu ebanzi yokubuka kokubili kwesithombe esimile nesiguquguqukayo.



17 × 17 inch umtshina wephaneli eyisicaba eguquguqukayo ye-radiography yedijithali kanye nesithombe se-fluoroscopic sesikhathi sangempela.



3. I-Radiography kanye ne-Dynamic Imaging ku-One Platform

 

Lolu hlelo luhlanganisa i-digital radiography, i-digital fluoroscopy, i-digital angiography kanye ne-digital spot imaging . Phakathi nokubuka okuguquguqukayo noma ukudlalwa kwesithombe, izithombe zezindawo ezinencazelo ephezulu zingashuthwa ukuze kuhlolwe eduze izindawo ezikhethiwe.

 

4. I-Flexible Multi-Dimensional Positioning

 

Uhlelo luhlinzeka ngokunyakaza kwemishini okuguquguqukayo ukusekela izikhundla ezihlukene zokuhlolwa kanye nezifunda ze-anatomical.

 

l I-Tube Column Swing
Ikholomu yeshubhu ye-X-ray ingashwiba isuka ku --45° iye ku-+45° , inikeze ukuguquguquka okwengeziwe kokuma kokuhlolwa kwezifunda ezihlukahlukene ze-anatomical.

 

l ±90° Ukuzungezisa Ithebula
Ithebula lokuhlola lingakwazi ukuzungeza ukusuka ku --90° ukuya ku-+90° , okuvumela isistimu ukuthi ibambe kokubili ukuma kwesithombe okuvundlile nokuqondile.

 

l I-SID Eguquguqukayo
Ibanga lomthombo ukuya esithombeni (SID) lingalungiswa lisuka ku -1000 liye ku-1800 mm , linikeze ukuguquguquka okukhulu kwezivivinyo ze-radiographic ezahlukene.

 

l I -Flexible Lateral Movement
Umtshina usekela ukunyakaza kwe-lateral okungu-320 mm , okuvumela inkambu yesithombe ukuthi ibekwe kabusha ezindaweni ezihlukahlukene ze-anatomical ngaphandle kokubeka kabusha isiguli njalo.



Isistimu ye-X-ray ye-DRF ebonisa ukushwibeka kweshubhu, ±90° ukuzungezisa ithebula, i-SID elungisekayo kanye nokunyakaza komtshina ongasemuva ovumelana nezimo.



5. I-Automatic Beam Collimation & Removable Grids

 

I -collimator kagesi ezenzakalelayo ivumela inkambu yokucabanga ukuthi ilungiswe ngokusho kokuhlolwa okukhethiwe kanye nesimo somzimba. Lokhu kusiza ukwenza lula ukuma futhi kunciphisa isidingo sokulungiswa okuphindaphindiwe kwenkundla ye-beam.

 

Isistimu ifakwe amagridi amabili asondelene kakhulu , angasuswa uma ukuthwebula isithombe okungenamagridi kuyadingeka ekuhlolweni okusebenzayo kwethamo eliphansi.



Isistimu ye-X-ray ye-DRF ebonisa ukungqubuzana kwemishayo okuzenzakalelayo namagridi akhiphekayo okuhlolwa kwe-radiographic okuguquguqukayo.



6. Indawo Yokusebenza Yokutholwa Kwezithombe Ezididiyelwe kanye Nokucubungula

 

Indawo yokusebenza ihlanganisa ukubhaliswa kwesiguli, ukulawula ukuchayeka, ukutholwa kwezithombe, ukucutshungulwa kwezithombe, ukudluliswa kanye nokubika . Amathuluzi okucubungula isithombe ahlanganisa ukuthuthukisa isithombe, ububanzi bewindi nokulungiswa kwezinga, ukunqampuna kwesithombe neminye imisebenzi yokucubungula.

 

Ngokuxhunywa kwesistimu, isixhumi esibonakalayo se-DICOM 3.0 sisekela ukuhlanganiswa nokugeleza kokusebenza kwesithombe sezokwelapha okuhambisanayo.

 

7. Imisebenzi Enwebekayo Yokugeleza Okuhlukile Komtholampilo

 

I-MCI0043 ingalungiselelwa ngemisebenzi eminingana yokuzikhethela. I-AEC ilawula ngokuzenzakalelayo isikhathi sokuchayeka ngokwemibandela yokuhlolwa. Ukuqapha kwe-DAP kuqopha ulwazi lomthamo wokuhlolwa, kuyilapho ukuthungwa kwesithombe kusekela ukuthwebula izithombe komgogodla ogcwele noma izitho ezingezansi. Ukucushwa okungakhethwa kukho futhi kufaka indawo yokusebenza yesikrini esithintwayo se-LCD kanye nekhonsoli ekhethekile yokuhlinza/eseduze.

 

Ukucaciswa Kwezobuchwepheshe

 

Isigaba

Ipharamitha

Ukucaciswa

Ukunikezwa kwamandla kagesi

Amandla kagesi

380 V ±38 V

Imvamisa

50 Hz ±10 Hz

Amandla

≥125 kVA

Ukumelana Kwangaphakathi

≤0.17 Ω

I-X-ray Generator

Amandla

84kw

I-Inverter Frequency

550 kHz

I-Radiography Tube Voltage

40–150 kV

I-Radiography Tube Yamanje

10–1000 mA

Isikhathi sokuchayeka

1–10000 ms

I-radiography mAs

0.1–1000 mAs

I-Fluoroscopy Tube Voltage

40–125 kV

I-Fluoroscopy Eqhubekayo Yamanje

0.5–10 mA

I-Pulsed Fluoroscopy Yamanje

5–20 mA

X-ray Tube

I-Focal Spot

0.6 mm / 1.2 mm

Amandla Okushisa e-Anode

420 kJ / 600 kHU

Isivinini se-Anode

9700 rpm ku-180 Hz / 2700 rpm ku-50 Hz

I-Engeli eqondiwe

12°

I-Dynamic Flat Panel Detector

Indawo Esebenzayo

427 × 427 mm

I-Pixel Matrix

3072 × 3072

I-Pixel Pitch

awu 139m

Ukuguqulwa kwe-A/D

16 bit

Ukulungiswa Okukhawulelwe

≥3.7 lp/mm

Ibanga lamandla

40–150 kVp

Ukuthola Okunamandla

Kufika ku-30 ​​fps

I-Collimator

Buka Ukukhanya

I-LED

Ukukhanya

> 100 lux

Isikhathi Sokukhanya Esibonakalayo

5–45 s iyalungiseka

Ukuhlunga

≥1 mm Al

Mechanical Movement

Ukuzungezisa Kwethebula Okuqondile

+90° kuya ku-90°

Ukunyakaza Okuqondile

1300 mm

Ibanga Lokuphakamisa Itafula ukuya Phansi (Ongakukhetha)

550-1350 mm

I-Lateral Movement

320 mm

I-SID

1000-1800 mm

I-Tube Swing

+45° kuya ku-45°

Ukuxhumana

Isixhumi esibonakalayo

I-DICOM 3.0

Imisebenzi Engazikhethela

I-AEC

Ongakukhetha

Ukuqapha kwe-DAP

Ongakukhetha

Ukuthunga Isithombe

Ongakukhetha

Isiteshi sokusebenza se-LCD sesikrini sokuthinta

Ongakukhetha

I-Specialized Surgical / Proximity Console

Ongakukhetha