IMINININGWANE YOMKHIQIZO
Ulapha: Ikhaya » Imikhiqizo » Izisetshenziswa ze-Ophthalmic » I-Auto refractometer/Keratometer » I -Auto Ref-Keratometer ene-Automatic Fogging | I-MECANMED

iyalayisha

I-Auto Ref-Keratometer ene-Automatic Fogging | I-MECANMED

I-MCO0022 Auto Ref-Keratometer ihlanganisa i-refraction ezenzakalelayo ne-keratometry, ihlinzeka nge-refraction ehlosiwe, ibanga lomfundi, kanye nedatha yokulinganisa i-cornea yokuhlolwa kwamehlo okuvamile.

 

Ukutholakala:
Ubuningi:
inkinobho yokwabelana ye-facebook
inkinobho yokwabelana ye-twitter
inkinobho yokwabelana ngomugqa
inkinobho yokwabelana ye-wechat
inkinobho yokwabelana ye-linkedin
inkinobho yokwabelana ye-pinterest
inkinobho yokwabelana ye-whatsapp
yabelana ngale nkinobho yokwabelana
  • MCO0022

  • I-MECANMED


Uhlolojikelele Lomkhiqizo

 

I- MC O 0022 Auto Ref-Keratometer iwuhlelo lokuxilonga lwe-ophthalmic. Ihlanganisa i-refraction ezenzakalelayo kanye ne-keratometry kudivayisi eyodwa. Uhlelo luhlinzeka ngedatha yenhloso ye-refractive kanye ne-corneal measurement, okuhlanganisa i-sphere, isilinda, i-eksisi, ibanga lomfundi, namapharamitha we-corneal.


Izicelo Zomtholampilo Nezimo Zokusebenzisa

 

Isicelo somtholampilo

Iqhaza Ekusetshenzisweni Komtholampilo

Ukuhlolwa kwe-Refraction & Ukuhlolwa Kombono

Ihlinzeka ngedatha yenhloso ye-refractive ukusekela ukuhlolwa kombono okuvamile kanye nokuhlonza amaphutha e-refractive.

I-Optical Prescription Assessment

Ihlinzeka ngezilinganiso zokuqagela eziyisisekelo ukuze kusekelwe okunye ukuphindaphinda okuqondile kanye nokuhlolwa kwencwadi kadokotela.

I-Corneal Curvature & Shape Assessment

Ihlinzeka ngedatha ye-corneal curvature ukusekela ukuhlolwa okujwayelekile komumo we-cornea kanye nokujwayelekile.

Ukuhlolwa Kwamehlo Okujwayelekile

Isekela ukugeleza komsebenzi okuvamile kokuhlolwa kwamehlo ngokunikeza idatha yokulinganisa ye-refractive ne-cornea ukuze kuqhutshekwe nokuhlolwa.

 

Izici Eziyinhloko Nokugqamisa Ubunjiniyela

 

I-Refraction & Keratometry kusistimu eyodwa

 

l I-Refractive Measurement: Ikala i-sphere, isilinda, i-eksisi, ibanga lomfundi, kanye nobubanzi obuncane obulinganisekayo bomfundi.

 

l I -Keratometry & Corneal Measurement: Isekela i-radius of curvature, i-corneal refraction, i-corneal astigmatism, i-corneal angle, nezilinganiso zobubanzi be-corneal.

 

Ukulinganisa Okuzenzakalelayo Kwenkungu

 

l Ithagethi yeFogging ezenzakalelayo: Isiza ukunciphisa iphutha lesilinganiso esihlobene nendawo yokuhlala . Lokhu kusekela ukuphindwa kwenhloso okungaguquki.

 

Ithagethi yenkungu ezenzakalelayo esetshenziswa ku-auto ref-keratometer ukusiza ukwehlisa iphutha lokulinganisa elihlobene nendawo yokuhlala.


Isilinganiso se-PD esizenzakalelayo

 

l Ukulinganisa Kwebanga Lomfundi Okuzenzakalelayo: Ikala ngokuzenzakalelayo futhi ibonise yesiguli inani le-PD .

 

l 30–85 mm Ibanga Lokulinganisa I-PD: Isekela ukulinganisa kwebanga lomfundi kububanzi obubanzi.

 

Iphrosesa ye-ARM nokucutshungulwa kwesithombe

 

l Ukucutshungulwa Kwesistimu Okusheshayo: Kuhlanganisa iphrosesa ye-ARM nobuchwepheshe bokucubungula izithombe obuthuthukisiwe bokusebenza okuphendulayo.

 

l Sula Ukuboniswa Kwesithombe: Isistimu yokucubungula izithombe inikeza izithombe zokulinganisa ezicacile ukuze zisekele ukubhekwa okuqondisiwe phakathi nokuhlolwa.

 

Isakhiwo Esizinzile Sokubona Nokulinganisa

 

l I -Stable Optical Path Design: Isekela ukuqondanisa okuzinzile kwe-optical kanye nokulinganisa okungaguquki kwe-refractive.

 

l I-Cast Light Rack Edidiyelwe: Irekhi ekhanyayo yamukela isakhiwo sokusakaza esibalulekile esinomshini we-CNC . Lokhu kuthuthukisa ukuzinza nokuvumelana kwesistimu yokulinganisa.

 

Sula 5.7' Umbala we-LCD nesixhumi esibonakalayo esibonakalayo

 

l 5.7-Intshi Umbala we-LCD: Inikeza isibonisi esicacile sezithombe zokulinganisa, amapharamitha, nemiphumela.

 

l Ukulungiswa Kwepharamitha Okunembile: Isixhumi esibonakalayo sivumela ukulungiswa kwezilungiselelo kufaka phakathi inani le-VD, ukunemba kokulinganisa, nemodi yokuphrinta..

 

5.7-intshi isixhumi esibonakalayo se-LCD sombala we-auto ref-keratometer ebonisa izilungiselelo zokulinganisa ezilungisekayo namapharamitha.


Ukucaciswa Kwezobuchwepheshe

 

MCO0022

Refractive -M Ukulinganisa kwe

Ibanga le-Vertex

0.0, 12.0, 13.75, 15.0 mm

I-Sphere

-20.00 kuye +20.00 D (0.12/0.25 D isinyathelo)

Isilinda

0.00 ukuya ku- ±10.00 D (0.12/0.25 D isinyathelo)

I-eksisi

1° ukuya ku- 180° (1° isinyathelo)

Ibanga lomfundi

30 kwe 85mm

Okuncane. Ububanzi Bomfundi Kuyalinganiseka

2.0 mm

Ithagethi

I-Automatic Fogging Target

I-Keratometry / Corneal Curvature Measurement

I-Radius of Curvature

5 ukuya ku 10 -mm (isinyathelo esingu-0.01 mm )

I-Corneal Refraction

33.00 kuya ku 67.00 -D (0.12/0.25 D isinyathelo)

I-Corneal Astigmatism

0.00 kuya ku 15.00 -D (0.12/0.25 D isinyathelo)

I-Angle yeCorneal

1° ukuya ku- 180° (1° isinyathelo)

I-Corneal Diameter

2.0 kwe 12.00 mm

Hardware SUkucaciswa kwe- s

Gada

5.7-intshi Umbala we-LCD

Iphrinta

Iphrinta Eshisayo Esheshayo

Umsebenzi Wokonga Amandla

VALIWE, 5, 15 amaminithi (kuyakhetheka)

Ukunikezwa kwamandla kagesi

I-AC 110-220 V, 50/60 Hz

Ubukhulu/Isisindo

288 (W) × 500 (D) × 480 (H) mm
14
kg

 

Isixazululo Esihlanganisiwe Sezisetshenziswa Ze-Ophthalmology

 

Njengomphakeli wemishini yezokwelapha enendawo eyodwa , i-MECANMED ingahlanganisa i -Auto Ref-Keratometer nezinto ezihambisanayo zokuxilonga zamehlo . Ndawonye, ​​lawa madivayisi angenza ukuhlolwa kwamehlo okudidiyelwe kanye nesistimu yokuxilonga . Ukucushwa kwemishini kungakhethwa ngokuya ngezidingo ezahlukene zomtholampilo kanye nezidingo zephrojekthi.

 

l I -Slit Lamp nge-Digital Camera & Software: Isekela ukuhlolwa okuningiliziwe kanye nemibhalo yedijithali yezakhiwo zamehlo angaphambili.

 

l I-Tonometer Engathinteki Egcwele Ngokuzenzakalelayo: Ihlinzeka ngokulinganisa kwengcindezi ye-intraocular okungathinteki njengengxenye yokuhlolwa kwamehlo okujwayelekile.

 

l I-OCT ezenzakalelayo :  Isekela ukucatshangelwa kwezingxenye zezinhlaka ze-ocular ukuze kuhlolwe okuningiliziwe kwe-ophthalmic.

 

l Ikhamera ye-Fundus: Ithwebula izithombe ze-fundus ukuze isekele ukuhlolwa nokubhalwa kwe-retina nezinye izakhiwo zamehlo angemuva.

 

l Ithebula Elihlanganisiwe Le-Ophthalmic: Ihlinzeka ngendawo yokusebenza edidiyelwe yokugeleza komsebenzi okuvamile kokuhlolwa kwamehlo.

 

ejwayelekile ukubuzwaImibuzo

 

Q1: Uyini umehluko phakathi kwe-auto refractometer kanye ne-auto ref-keratometer?

 

I -auto refractometer ihlinzeka ngokuyinhloko ngezilinganiso zokuphinda zenzeke. Ngokuqhathanisa, i -auto ref-keratometer ihlanganisa ukuphikiswa nokukala kwe-corneal curvature kudivayisi eyodwa. Ngakho-ke, ilungele ukuhlolwa kwamehlo okuvamile okudinga kokubili ukulinganiswa kwe-refractive kanye ne-cornea.

 

Q2: Yini okufanele abathengi bayicabangele lapho bekhetha i-auto ref-keratometer?

 

Okucatshangelwayo okubalulekile kuhlanganisa:

 

l Ukuthi i-keratometry iyadingeka yini ngaphezu kwe-refraction

 

l adingekayo Amabanga okulinganisa

 

l Isibonisi nesixhumi esibonakalayo esisebenzayo

 

l Izidingo zokuphrinta

 

l Izidingo zokudlulisa

 

l Indawo yokufaka etholakalayo

 

Abathengi kufanele futhi baqinisekise izidingo zamandla kagesi wendawo nanoma yikuphi ukuxhunywa kwemishini okuhlosiwe ngaphambi koku-oda.

 

Q3: Ingabe imiphumela yokulinganisa ingaphrintwa noma idluliselwe kwezinye izinto zokusebenza?

 

I -MC O 0022 ifaka iphrinta eshisayo esheshayo yemiphumela yokuhlolwa futhi yabelana ngedatha ne- MCO0415 Vision Tester . Abathengi abafuna ukuhamba komsebenzi okuxhunyiwe kufanele baqinisekise ukucushwa kwesistimu okuhlosiwe ngaphambi koku-oda.

 

Q4: Ingabe i-auto ref-keratometer ingahlinzekwa njengengxenye yesisombululo esiphelele semishini ye-ophthalmology?

 

Yebo. Njengomhlinzeki wemishini yezokwelapha enendawo eyodwa , i-MECANMED ingahlanganisa i -Auto Ref-Keratometer nezinto ezihambisanayo ze-ophthalmic ezifana nesibani esisikiwe, i-tonometer engathinteki, i-OCT, ikhamera ye-fundus, kanye netafula elihlanganisiwe le-ophthalmic. Ukucushwa kwemishini kungakhethwa ngokuya ngezidingo zephrojekthi.
Okwedlule: 
Olandelayo: