PRODUCT DETAIL
You are here: Home » Products » Ophthalmic Equipment » Auto refractometer/Keratometer » Auto Ref-Keratometer with Automatic Fogging | MECANMED

loading

Auto Ref-Keratometer with Automatic Fogging | MECANMED

The MCO0022 Auto Ref-Keratometer combines automatic refraction and keratometry, providing objective refractive, pupil distance, and corneal measurement data for routine ophthalmic examinations.

 

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
  • MCO0022

  • MECANMED


Product Overview

 

The MCO0022 Auto Ref-Keratometer is an ophthalmic diagnostic system. It combines automatic refraction and keratometry in one device. The system provides objective refractive and corneal measurement data, including sphere, cylinder, axis, pupil distance, and corneal parameters.


Clinical Applications & Use Cases

 

Clinical Application

Role in Clinical Use

Refraction Examination & Vision Screening

Provides objective refractive data to support routine vision assessment and preliminary identification of refractive errors.

Optical Prescription Assessment

Provides baseline refractive measurements to support further subjective refraction and prescription evaluation.

Corneal Curvature & Shape Assessment

Provides corneal curvature data to support routine evaluation of corneal shape and regularity.

Routine Ophthalmic Examination

Supports routine eye examination workflows by providing objective refractive and corneal measurement data for further assessment.

 

Core Features & Engineering Highlights

 

Refraction & Keratometry in One System

 

l Refractive Measurement: Measures sphere, cylinder, axis, pupil distance, and minimum measurable pupil diameter.

 

l Keratometry & Corneal Measurement: Supports radius of curvature, corneal refraction, corneal astigmatism, corneal angle, and corneal diameter measurements.

 

Automatic Fogging Measurement

 

l Automatic Fogging Target: Helps reduce accommodation-related measurement error. This supports more consistent objective refraction.

 

Automatic fogging target used in an auto ref-keratometer to help reduce accommodation-related measurement error.


Automatic PD Measurement

 

l Automatic Pupil Distance Measurement: Automatically measures and displays the patient's PD value.

 

l 30–85 mm PD Measurement Range: Supports routine pupil distance measurement across a broad range.

 

ARM Processor & Image Processing

 

l Fast System Processing: Combines an ARM processor with advanced image-processing technology for responsive operation.

 

l Clear Image Display: The image-processing system provides clear measurement images to support target observation during testing.

 

Stable Optical & Measuring Structure

 

l Stable Optical Path Design: Supports stable optical alignment and consistent refractive measurement.

 

l Integrated Cast Light Rack: The light rack adopts an integral casting structure with CNC machining. This improves stability and consistency of the measuring system.

 

Clear 5.7" Color LCD & Intuitive Interface

 

l 5.7-Inch Color LCD: Provides a clear display for measurement images, parameters, and results.

 

l Intuitive Parameter Adjustment: The interface allows adjustment of settings including VD value, measurement precision, and print mode.

 

5.7-inch color LCD interface of an auto ref-keratometer showing adjustable measurement settings and parameters.


Technical Specification

 

MCO0022

Refractive Measurement

Vertex Distance

0.0, 12.0, 13.75, 15.0 mm

Sphere

-20.00 to +20.00 D (0.12/0.25 D step)

Cylinder

0.00 to ±10.00 D (0.12/0.25 D step)

Axis

1° to 180° (1° step)

Pupil Distance

30 to 85 mm

Min. Pupil Diameter Measurable

2.0 mm

Target

Automatic Fogging Target

Keratometry / Corneal Curvature Measurement

Radius of Curvature

5 to 10 mm (0.01 mm step)

Corneal Refraction

33.00 to 67.00 D (0.12/0.25 D step)

Corneal Astigmatism

0.00 to 15.00 D (0.12/0.25 D step)

Angle of Corneal

1° to 180° (1° step)

Corneal Diameter

2.0 to 12.00 mm

Hardware Specifications

Monitor

5.7-inch Color LCD

Printer

Fast Thermal Printer

Power Saving Function

OFF, 5, 15 mins (selectable)

Power Supply

AC 110-220 V, 50/60 Hz

Dimensions/Weight

288 (W) × 500 (D) × 480 (H) mm
14
kg

 

Integrated Ophthalmology Equipment Solution

 

As a one-stop medical equipment supplier, MECANMED can combine the Auto Ref-Keratometer with complementary ophthalmic diagnostic equipment. Together, these devices can form an integrated ophthalmic examination and diagnostic system. Equipment configurations can be selected according to different clinical needs and project requirements.

 

l Slit Lamp with Digital Camera & Software: Supports detailed examination and digital documentation of anterior eye structures.

 

l Full-Automatic Non-Contact Tonometer: Provides non-contact intraocular pressure measurement as part of routine ophthalmic examinations.

 

l Automatic OCT: Supports cross-sectional imaging of ocular structures for more detailed ophthalmic assessment.

 

l Fundus Camera: Captures fundus images to support examination and documentation of the retina and other posterior eye structures.

 

l Ophthalmic Combined Table: Provides an integrated workstation for routine ophthalmic examination workflows.

 

Frequently Asked Questions

 

Q1: What is the difference between an auto refractometer and an auto ref-keratometer?

 

An auto refractometer primarily provides objective refractive measurements. By comparison, an auto ref-keratometer combines refraction with corneal curvature measurement in one device. Thus, it is suitable for routine eye examinations that require both refractive and corneal measurements.

 

Q2: What should buyers consider when choosing an auto ref-keratometer?

 

Key considerations include:

 

l Whether keratometry is required in addition to refraction

 

l The required measurement ranges

 

l Display and operating interface

 

l Printing requirements

 

l Data transmission needs

 

l Available installation space

 

Buyers should also confirm local voltage requirements and any intended equipment connections before ordering.

 

Q3: Can the measurement results be printed or transferred to other equipment?

 

The MCO0022 features a fast thermal printer for test results and shares data with the MCO0415 Vision Tester. Buyers seeking connected workflows must confirm the intended system configuration before ordering.

 

Q4: Can the auto ref-keratometer be supplied as part of a complete ophthalmology equipment solution?

 

Yes. As a one-stop medical equipment supplier, MECANMED can combine the Auto Ref-Keratometer with complementary ophthalmic equipment such as a slit lamp, non-contact tonometer, OCT, fundus camera, and ophthalmic combined table. Equipment configuration can be selected according to the project requirements.
Previous: 