| Availability: | |
|---|---|
| Quantity: | |
MCL2142
MECANMED
The MCL2142 13C-Urea Breath Test Analyzer is a high-precision system. It is built for the clinical detection and testing of H. pylori infections in the human stomach. This H. pylori detector is widely recognized as the clinical "Gold Standard" for non-invasive gastric diagnostics. It delivers exceptionally reliable results without requiring a patient endoscopy.
The full configuration of the MCL2142 features a medical-grade desktop setup. The main unit houses the optical signal sensors, the sample collection parts, and the main control system. This setup also includes a computer interface, a power cord, and a built-in printer for fast diagnostic reports.
This medical breath analyzer utilizes advanced infrared spectroscopy to measure the delta value (). This value shows the difference between the ratio of 13C to 12C (13C/12C) in the breath of the patient. The system checks this ratio by comparing breath samples taken before and after the patient drinks a 13C-labeled urea liquid.
The H. pylori bacteria contain active urease enzymes. These enzymes break down the swallowed 13C-urea into ammonia and 13CO2 gas. This gas enters the bloodstream and leaves the body through the lungs. The clinical testing criteria are then accurately determined by the machine's measured Delta Over Baseline, or DOB, value.
l DOB > 4.0‰: Positive (H. pylori infection confirmed).
l DOB < 4.0‰: Negative (Clear of active H. pylori infection).
l DOB ≈ 4.0‰ (Borderline Zone): Suspected infection (Clinical re-testing or auxiliary diagnostic verification recommended).
This Helicobacter Pylori test equipment is highly automated and non-invasive. It has become an essential asset for expanding throughput across multiple hospital divisions.
l Clinical Laboratories / Medical Testing Centers
l Physical Examination & Wellness Centers
l Gastroenterology Departments
l Outpatient Clinics & Internal Medicine Units
Traditional lab cultures or stool tests take several days to complete. In contrast, the MCL2142 delivers accurate analysis results within 140 seconds, or under 3 minutes. This rapid processing time allows clinics to shorten patient wait times and optimize daily appointment schedules easily.
This system eliminates patient anxiety caused by blood draws or invasive tubes. The MCL2142 uses a simple breath-collection method. It uses lightweight, odorless breath collection bags that require zero needles and cause zero discomfort.
Unlike radioactive 14C options, the 13C stable isotope used by this system is completely non-radioactive. It is proven 100% safe for children, elderly patients, and pregnant/lactating women. This high level of safety allows hospitals to offer universal screening without any health concerns.
Fast testing speed combined with affordable test kits helps medical centers recover their initial investment quickly. This allows facilities to build a steady, profitable revenue stream over time.
The MCL2142 plays a vital role across multiple hospital departments. It serves as a core tool for complete gastric health management.
Clinical Department |
Primary Application Scenarios |
Physical Examination & Wellness Centers |
Routine, high-volume H. pylori screening during annual health checkups; essential preventative screening for gastric ulcers and early-stage gastric cancer risks. |
Gastroenterology & Internal Medicine |
Rapid differential diagnosis of patients exhibiting symptoms of dyspepsia, gastritis, and peptic ulcers; convenient post-treatment follow-up to confirm successful bacterial eradication. |
Clinical Laboratories |
Automated, batch-ready processing of sample bags delivered from outpatient clinics, facilitating centralized data management and error-free laboratory workflows. |
Pediatric & Obstetric Clinics |
Safe, non-invasive point-of-care testing specifically tailored for sensitive patient populations who cannot tolerate endoscopy or radioactive diagnostic tools. |
1. High Efficiency
The machine features fast operation and automated batch testing. It delivers full analysis within just 2 to 3 minutes for each set of samples. This help facilities maximize daily patient flow.
2. Simple & Intelligent Workflow
The system features a simple, one-touch user interface. It is managed by a fully automated control system that eliminates the need for long staff training.
3. Unrivaled Accuracy
The machine uses high-precision infrared spectroscopy to maintain high testing accuracy Ssd< 0.3‰. This design completely removes human error from the measurement cycle.
1. Blow 1st Bag: The patient blows gently into the baseline breath collection bag to establish the initial control sample.
2. Take Tablet: The patient swallows one 13C-Urea capsule/tablet with a small amount of plain water.
3. Wait 20 Minutes: The patient rests comfortably for exactly 20 minutes. During this time, the stable isotope reacts naturally inside the stomach environment.
4. Blow 2nd Bag: The patient blows into the second breath collection bag to gather the diagnostic sample.
5. Test with Analyzer: The operator plugs both collection bags into the dedicated testing ports of the MCL2142. Next, pressing start delivers a printed diagnostic report within 140 seconds.
To run clinical tests, the analyzer operates alongside dedicated 13C-Urea Breath Test Kits. Each consumable set comes fully equipped with the 13C-Urea test reagent, available in tablet or powder format. It also includes matching baseline and diagnostic collection bags designed for simple air sample collection.
Note for Procurement Managers & Medical Distributors: Every medical facility and distributor aims to maintain smooth clinic operations and lower shipping costs. To help achieve this, MECANMED recommends ordering bulk quantities of matching consumable sets with your machine. We provide full, bundled supply packages to ensure you enjoy an uninterrupted supply chain.
Running out of matching test kits is a big risk for medical facilities and distributors. Past the first machine order, MECANMED promises a steady supply of certified test kits. Sourcing supply kits long-term from one source ensures ongoing compatibility and zero downtime.
Remote machine setup can raise fears of setup delays. MECANMED fixes this by sending full user guides, clear video walkthroughs, and spec sheets. In key regions across the Philippines and parts of Africa, local engineers offer on-site setup and maintenance service. This support ensures smooth work from day one.
The MCL2142 features a wide-range internal power module compatible with global electrical networks from AC 100V to 240V at 50Hz or 60Hz. It uses less than 100W of power and features a compact desktop design (330mm × 435mm × 236mm). The machine requires no special electrical wiring or large space, making it easily adaptable to standard clinical testing rooms.
The MCL2142 features a built-in printer inside the machine. Once the analysis is complete (≤140 seconds), the analyzer automatically print out the patient diagnostic report. The operators don't need to deal with compatibility issues caused by external printers. It ensure immediate, point-of-care results.
While 13C test kits are slightly higher than radioactive 14C test kits, the total operational costs for 13C systems are much lower. The 14C systems require the cost of nuclear waste disposal licenses, radioactive storage protection, and restrictive environmental inspections. The MCL2142 13C system avoids all environmental regulatory fees, delivering higher net profits over time.
Yes. We secure your bulk hardware purchase with a robust, uninterrupted supply chain of matching consumable sets containing the 13C-Urea Breath Test Kits and breath collection bags.
Are you ready to upgrade your clinical screening capacity and streamline your laboratory workflows? Partner with MECANMED to secure the market's preferred H. Pylori detector machine along with a secure, stable supply chain. Contact our sales team today to receive expert configuration advice, comprehensive technical datasheets, and exclusive pricing.
Simply submit your request with the following details:
l Required Configuration & Accessories: Specify your estimated monthly volume for matching 13C-Urea Breath Test Kits along with the analyzer main unit.
l Target Clinical Setup: Hospital Laboratory, Physical Examination & Wellness Center, Gastroenterology Department, or Medical Equipment Distribution Stock.
l Destination Country & Estimated Order Quantity: To help us calculate optimized ocean/air freight and local customs compliance for your region.
Based on your local market requirements, our sales team will deliver a custom plan for your machine and matching supplies within 24 hours!