MeCan Medical Best Quality Anestesia Machine Hospital VaporizerAnesthesia MachineWithVentilatorFactory,MeCan provide one-stop solutions for new hospitals,clinics,labs and universities,has helped 270 hospitals,540 clinics,190 vet clinics to set up in Malaysia,Africa,Europe,etc.we can save your time,energy and money.
Quantity: |
---|
Place of Origin:CN;GUA
Model Number:MCA-301
Brand Name:MeCan
Type:Anesthesia Equipments & Accessories
Instrument classification:Class II
Model: MCA-301
1. Applied for closed, semi-closed, semi-open inhalation anesthesia, controlled or assisted ventilation, monitoring and display patients’ ventilation parameters
2. Applied for adult and pediatric
3. Integrated anesthetic ventilation system, APL security air relief valve is available
4. Vaporizers: Advanced temperature, flow and pressure compensation technology, Isofurane, Enfurance, Halothane and Sevoflurance as per option
5.8.4” TFT-LCD display screen
Type:Electronically controlled,Pneumatic driven
Patient spectrum: Pediatric to bariatric
Mode of ventilation: VCN, SIGH, SIMV, Stand-by, Manual, PEEP(Optional)
Hypoxic guard system: N2O cut-off valve, O2 concentration no less than 25%
Safety valve: <12.5kpa
Monitoring:VT, MV, BPM, Paw, FiO2, Lung compliance
Waveform: Pressure-time, flow-time, pressure-volume loop, volume-time (Optional), flow-volume loop (Optional)
Power: AC 220V±10%, 50Hz±2%, built-in battery support
Gas:O2, N2O, air (Optional)
Alarm: Optimal multi-class alarm unit, VT beyond limitation, upper and lower limitation of ventilation, upper and lower limitation of ventilation, upper and lower limitation of airway pressure, asphyxiation, current failure, gas source hypotonic, gas circuit abnormity, upper and lower limitation of CO2 concentration (Optional)
Prompt and protection: Prompt for parameter limitations, protection for unreasonable parameter setting.
Place of Origin:CN;GUA
Model Number:MCA-301
Brand Name:MeCan
Type:Anesthesia Equipments & Accessories
Instrument classification:Class II
Model: MCA-301
1. Applied for closed, semi-closed, semi-open inhalation anesthesia, controlled or assisted ventilation, monitoring and display patients’ ventilation parameters
2. Applied for adult and pediatric
3. Integrated anesthetic ventilation system, APL security air relief valve is available
4. Vaporizers: Advanced temperature, flow and pressure compensation technology, Isofurane, Enfurance, Halothane and Sevoflurance as per option
5.8.4” TFT-LCD display screen
Type:Electronically controlled,Pneumatic driven
Patient spectrum: Pediatric to bariatric
Mode of ventilation: VCN, SIGH, SIMV, Stand-by, Manual, PEEP(Optional)
Hypoxic guard system: N2O cut-off valve, O2 concentration no less than 25%
Safety valve: <12.5kpa
Monitoring:VT, MV, BPM, Paw, FiO2, Lung compliance
Waveform: Pressure-time, flow-time, pressure-volume loop, volume-time (Optional), flow-volume loop (Optional)
Power: AC 220V±10%, 50Hz±2%, built-in battery support
Gas:O2, N2O, air (Optional)
Alarm: Optimal multi-class alarm unit, VT beyond limitation, upper and lower limitation of ventilation, upper and lower limitation of ventilation, upper and lower limitation of airway pressure, asphyxiation, current failure, gas source hypotonic, gas circuit abnormity, upper and lower limitation of CO2 concentration (Optional)
Prompt and protection: Prompt for parameter limitations, protection for unreasonable parameter setting.