The Electric IV Pump is equipped with advanced technology that ensures precise control over infusion rates, volumes, and dosages, making it an essential tool for healthcare professionals in clinical settings.
Availability: | |
---|---|
Quantity: | |
MCS0943
MeCanMed
Automatic Volumetric Infusion Pump
Model:MCS0943
The reliable and efficient pump is essential for a wide range of medical procedures, including surgery, intensive care, and chemotherapy. Its compact size and portable design make it easy to transport and use in various clinical settings.
Features:
Compact structure and light weight;
Simple operation, easy to use;
Low working noise;
Three working modes;
Sound and light alarm;
Real-time display of cumulative injection volume, easy clinical observation;
After the preset volume is completed, it will automatically transfer to KVO speed.
Specifications:
Pumping Mechanism | Curvilinear peristaltic |
IV Set | Compatible with IV sets of any standard |
Flow Rate | 0.1-1500 ml/h (in 0.1 ml/h increments) |
Purge, Bolus | 100-1500 ml/h (in 1 ml/h increments) Purge when pump stops, bolus when pump starts |
Bolus volume | 1-20 ml (in 1 ml increments) |
Accuracy | ±3% |
VTBI | 1-9999 ml |
Infusion Mode | ml/h, drop/min, time-based |
KVO Rate | 0.1-5 ml/h (in 0.1 ml/h increments) |
Alarms | Occlusion, air-in-line, door open, end program, low battery, end battery, AC power off, motor malfunction, system malfunction, reminder alarm |
Additional Features | Real-time infused volume / bolus rate / bolus volume / KVO rate, automatic power switching, mute key, purge, bolus, system memory, key locker, change flow rate without stopping the pump |
Occlusion Sensitivity | High, medium, low |
Air-in-line Detection | Ultrasonic detector |
Wireless management | Optional |
Power Supply, AC | 110/230 V (optional), 50-60 Hz, 20 VA |
Battery | 9.6±1.6 V, rechargeable |
Battery Life | 5 hours at 30 ml/h |
Working Temperature | 10-40℃ |
Relative Humidity | 30-75% |
Atmospheric Pressure | 700-1060 HPA |
Size | 174*126*215 mm |
Weight | 2.5 kg |
Safety Classification | Class , type CF |
Automatic Volumetric Infusion Pump
Model:MCS0943
The reliable and efficient pump is essential for a wide range of medical procedures, including surgery, intensive care, and chemotherapy. Its compact size and portable design make it easy to transport and use in various clinical settings.
Features:
Compact structure and light weight;
Simple operation, easy to use;
Low working noise;
Three working modes;
Sound and light alarm;
Real-time display of cumulative injection volume, easy clinical observation;
After the preset volume is completed, it will automatically transfer to KVO speed.
Specifications:
Pumping Mechanism | Curvilinear peristaltic |
IV Set | Compatible with IV sets of any standard |
Flow Rate | 0.1-1500 ml/h (in 0.1 ml/h increments) |
Purge, Bolus | 100-1500 ml/h (in 1 ml/h increments) Purge when pump stops, bolus when pump starts |
Bolus volume | 1-20 ml (in 1 ml increments) |
Accuracy | ±3% |
VTBI | 1-9999 ml |
Infusion Mode | ml/h, drop/min, time-based |
KVO Rate | 0.1-5 ml/h (in 0.1 ml/h increments) |
Alarms | Occlusion, air-in-line, door open, end program, low battery, end battery, AC power off, motor malfunction, system malfunction, reminder alarm |
Additional Features | Real-time infused volume / bolus rate / bolus volume / KVO rate, automatic power switching, mute key, purge, bolus, system memory, key locker, change flow rate without stopping the pump |
Occlusion Sensitivity | High, medium, low |
Air-in-line Detection | Ultrasonic detector |
Wireless management | Optional |
Power Supply, AC | 110/230 V (optional), 50-60 Hz, 20 VA |
Battery | 9.6±1.6 V, rechargeable |
Battery Life | 5 hours at 30 ml/h |
Working Temperature | 10-40℃ |
Relative Humidity | 30-75% |
Atmospheric Pressure | 700-1060 HPA |
Size | 174*126*215 mm |
Weight | 2.5 kg |
Safety Classification | Class , type CF |