Hospital Medical ICU Ventilator Machine with Air Compressor

Can do invasive ventilator, professional used for the COVID-19, 12.1 inch Touch screen, build-in battery and accessories and nebulizer, with Air compressor and humidifier,support Invasive & Non-invasive, High flow oxygen therapy, with CE approved
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Hospital Medical ICU Ventilator with Air Compressor

Model: MCV-3010

Can do invasive ventilator, professional used for the COVID-19, 12.1 inch Touch screen, build-in battery and accessories and nebulizer, with Air compressor and humidifier,support Invasive & Non-invasive, High flow oxygen therapy, with CE approved

Specification

1.Ventilation Mode

IPPV, SIGH, A/C (SIPPV), SIMV, MANUAL, PEEP, CPAP/SPONT (standard)

PCV, PSV, BI-LEVEL, S,T, S/T (optional)

2.Parameters

Tidal volume: 20~2000mL Ventilation volume per minute: 0L~20L

Frequency: 1~100/min I/E Ratio: 4:1~1:8

Holding time: 0~6s O2 concentration: 21~100% adjustable.

CPAP: 0~2.0KPaSafety Pressure ≤12.5KPa

PEEP: 0~3.0KPa Pressure limitation: 0.5~8.0KPa

3.Main Features of the ICU Ventilator:

1. Microprocessor controlled, Pneumatically driven, electronically controlled

2. 12.1"TFT touch screen, user friendly interface

3. Built-in medical air compressor, built-in backup battery up to 3hrs

4. LCD display ventilation parameters, preset parameters alarm indication and breathing waveform

5. Applied for adult and child

6. CE marked

4.Air Compressor Technique Infornation

7. Output pressure: 0.4MPa ±0.1MPa

8. Noise ≤50dB

9. Power: AC 220V ± 10%, 50Hz ± 2%

5.Inspiration Trigger Sensitivity of Medical Ventilator

pressure -2.0KPa (base on PEEP)

flow: 1~30L/min

Sign: 1-5 (per 100 times)

6.Ventilation Monitoring

Tidal volume,Minute ventilation,Frequency,Airway Pressure, inspiration time, PEEP, FiO2, PCV,PSV

Waveform of time-airway Pressure.

7.Alarm (Audible and visible reminding)

No tidal volume, ventilation volume is too high (low) , Airway Pressure is too high (low),

frequency is too high, AC Power off , back up battery voltage is too low

8.Technique Infomation

Gas source: Oxygen, Air

Working Pressure: 0.4Mpa

Reserve Condition: Temperature:-10~40°C,Relative humidity: ≤90%

Working condition: Temperature:5~40 °C, Relative humidity:≤80%

Package: 72*69*122cm, 83kg per unit

5 units have stock now, welcome to order!