64 128 Slice CT Scanner
Descriptio:
MCI0010 128 segmenta CT scanner designata cum speciebus superioribus inclusis 4cm-latis detectoris, 8M tubi maculae volantis, et 80kw altae intentionis generantis, permittens applicationes provocantes ad scan cardiacum.
Formularium:
Potentia: 80 kW
Gantry Bore: 70 cm
Scan Speed: 179.5mm/s
Quisque ornare:
1.40 mm Z-axis coverage et 8 M tubus altam intuens efficientiam patitur.
2.3D multi-frequency acquisitio technologiae efficit praestantiorem imaginem qualitatem cum 128 segmentis per rotationem.
3. Detector praestat sufficientem samplicationem per rotationem cum low afterglow et artificia reducta.
4.NanoDose Iterativa et intelligentes mA (imA) algorithms efficiunt dosem inferiorem, servata imagine qualitatis.
5.1024 x 1024 Matrix Mega-pixel singula laesiones plene ostendit.
6.AI efficax workflow praebet facilem et commodam operationem.
7.Robust hardware stabilis cursus permittit.
Specification of 64/128 Slice CT Scanner :
| Model | MCI0009 64 crustae | MCI0010 128 crustae |
| Apertura | 70cm | 70cm |
| Slices/360° | 64 | 128 |
| Potentia rate | 80KW | 80KW |
| Jejunium tempus gyrationis | 0.39s/360° | 0.39s/360° |
| Longissimum intuens tempus | 100s | 100s |
| Tilt | ±30° | ±30° |
| X tubus calor facultatem | 8.0 MHU | 8.0 MHU |
| KV range | 80-140kV | 80-140kV |
| MA range | 10-630mA | 10-630mA |
| Mensa motus range | 1800mm | 1800mm |
| Longissimum scanning range | 1700mm | 1700mm |
| Mensa elevatio range | 500mm | 500mm |
| Mensa pondus onus | 205kg | 205kg |
| Detector ordines | 64 | 64 |
| Detectors coverage in Z-axis | 10mm | 10mm |
| Numerus detectors per row | 704 | 704 |
| Detector Z-axis coverage | 40mm | 40mm |
| picem range | 0.25-1.75 | 0.25-1.75 |
| Crassitudo | 0.625mm | 0.625mm |
| Imago Reconstruction matricis | 1024× 1024 | 1024× 1024 |
| Imago ostentationem matrix | 1024× 1024 | 1024× 1024 |
| Resolutio localis: | 20LP/cm@0%MTF | 20LP/cm@0%MTF |
| VR | Ita | Ita |
| MPR | Ita | Ita |
| CPR | Ita | Ita |
| SSD | Ita | Ita |
| MIP | Ita | Ita |
| MinP | Ita | Ita |
| iteratio | Ita | Ita |
| Aliquam Application Fusce | Ad libitum Volume Application (Package Cardiac Software, ECG-Mod Coronary Dose De revolutionibus) | Include cardiac Software Package, ECG-Mod Coronarius Triticum De revolutionibus |