Pumping Mechanism | Curvilinear peristaltic |
IV Set | Compatible with IV sets of any standard |
Flow Rate | 0.1-1500 ml/h (in 0.1 ml/h increments) |
Purge, Bolus | 100-1500 ml/h (in 1 ml/h increments) Purge when pump stops, bolus when pump starts |
Bolus volume | 1-20 ml (in 1 ml increments) |
Accuracy | ±3% |
VTBI | 1-9999 ml |
Infusion Mode | ml/h, drop/min, time-based |
KVO Rate | 0.1-5 ml/h (in 0.1 ml/h increments) |
Alarms | Occlusion, air-in-line, door open, end program, low battery, end battery, AC power off, motor malfunction, system malfunction, reminder alarm |
Additional Features | Real-time infused volume / bolus rate / bolus volume / KVO rate, automatic power switching, mute key, purge, bolus, system memory, key locker, change flow rate without stopping the pump |
Occlusion Sensitivity | High, medium, low |
Air-in-line Detection | Ultrasonic detector |
Wireless management | Optional |
Power Supply, AC | 110/230 V (optional), 50-60 Hz, 20 VA |
Type:Anesthesia Equipments & Accessories
Place of Origin:CN;GUA
Instrument classification:Class II
Brand Name:Mecan
Model Number:MCL-8052N
MCL-8052N
Pumping Mechanism | Curvilinear peristaltic |
IV Set | Compatible with IV sets of any standard |
Flow Rate | 0.1-1500 ml/h (in 0.1 ml/h increments) |
Purge, Bolus | 100-1500 ml/h (in 1 ml/h increments) Purge when pump stops, bolus when pump starts |
Bolus volume | 1-20 ml (in 1 ml increments) |
Accuracy | ±3% |
VTBI | 1-9999 ml |
Infusion Mode | ml/h, drop/min, time-based |
KVO Rate | 0.1-5 ml/h (in 0.1 ml/h increments) |
Alarms | Occlusion, air-in-line, door open, end program, low battery, end battery, AC power off, motor malfunction, system malfunction, reminder alarm |
Additional Features | Real-time infused volume / bolus rate / bolus volume / KVO rate, automatic power switching, mute key, purge, bolus, system memory, key locker, change flow rate without stopping the pump |
Occlusion Sensitivity | High, medium, low |
Air-in-line Detection | Ultrasonic detector |
Wireless management | Optional |
Power Supply, AC | 110/230 V (optional), 50-60 Hz, 20 VA |