MeCan Medical 60 Test/Hour 22 Parameters 3-diff Intelligent Fully Automated Hematology Analyzer manufacturers From China,MeCan offer professional service,our team is well-tained. Every equipments from MeCan gets passed strict quality inspection,and final passed yield is over 99.9%.
Availability: | |
---|---|
Quantity: | |
Model:MCL-HA002
Simple Operation Low Consumption
1.Sample volume venous blood 9.6μL, capillary blood 20μL.
2.Remained reagent volume detected and reminder the operator.
3.Connect external printer as mini matrix printer, ink jet, stylus printer
and laser printer.
4.Each kind data transmitted to external computer by RS232 port.
Advanced Design Stable Performance
1.Automatic sleep and wake up, saving energy. The sampling needle be automatically back and out while stand by and wake up. It protects safe sampling and avoids contamination caused by long time exposure.
2.Large quantity test results storage, at least 400 thousand test results with
comprehensive information. Extended SD memory supported.
3.Many reference value ranges (children, adult and the aged). The
appropriate reference value range could be automatically selected
according to the inputted age and sex.
Accurate Analysis Perfect Quality
1.Analysis mode includes venous blood, caillary blood and prediluted.
2.Quality control mode of LJ, X-B and X-r. Westguard quality control regulation.
3.Manual and automatic calibration available. Fresh blood calibration available also.
4.Furmished with original reagents. Conform to the demand of Intemnational Standard Traceable System.
Convenient Maintenance Safety & Eco-protection
1.Automatic & Ielligent function of diagnosis and maintenance; the log sheet for maintenance and malfunction could be established automatically.
2.Soak, back & forth flush, high pressure burming block-clearing.
3.Leaf door construct for convenient maintenance.
Specifications:
Function | Automated WBC 3-Part |
Parameters | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, LYM%, LYM#, GRAN%, MID%, MID#,PDW, MPV, PCT, RCDW, LCDW, RDW, P-LCR and WBC, RBC, PLT |
three histograms | |
Principal | Electronic impedance, SFT method for hemoglobin |
Throughput | ≥60T/H |
Analysis Mode | Optional venous blood, anticoagulant blood and prediluted blood |
Sample Volume | Anticoagulant whole blood≤9.6μL, Anticoagulant capillary blood ≤9.6μL, prediluted capillary blood≤20μL, the sample volume for |
repeating two times testing and avoiding second sampling | |
Block-clearing: | Soak and washing back and forth, high pressure burning. Boast the function of monitoring incomplete blockage |
Working Mode: | Automatic sampling, detecting automatic testing, furnished with dilutor, no need diluting outside. Automatic dispensing lyse and |
making second diluting automatically | |
Alarm | Automated system diagnosis, self testing, fault alarm and reagent shortage alarm |
Standby Protection | 24 hours switch on, automatic sleep and wake up function |
Product packaging:
Model:MCL-HA002
Simple Operation Low Consumption
1.Sample volume venous blood 9.6μL, capillary blood 20μL.
2.Remained reagent volume detected and reminder the operator.
3.Connect external printer as mini matrix printer, ink jet, stylus printer
and laser printer.
4.Each kind data transmitted to external computer by RS232 port.
Advanced Design Stable Performance
1.Automatic sleep and wake up, saving energy. The sampling needle be automatically back and out while stand by and wake up. It protects safe sampling and avoids contamination caused by long time exposure.
2.Large quantity test results storage, at least 400 thousand test results with
comprehensive information. Extended SD memory supported.
3.Many reference value ranges (children, adult and the aged). The
appropriate reference value range could be automatically selected
according to the inputted age and sex.
Accurate Analysis Perfect Quality
1.Analysis mode includes venous blood, caillary blood and prediluted.
2.Quality control mode of LJ, X-B and X-r. Westguard quality control regulation.
3.Manual and automatic calibration available. Fresh blood calibration available also.
4.Furmished with original reagents. Conform to the demand of Intemnational Standard Traceable System.
Convenient Maintenance Safety & Eco-protection
1.Automatic & Ielligent function of diagnosis and maintenance; the log sheet for maintenance and malfunction could be established automatically.
2.Soak, back & forth flush, high pressure burming block-clearing.
3.Leaf door construct for convenient maintenance.
Specifications:
Function | Automated WBC 3-Part |
Parameters | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, LYM%, LYM#, GRAN%, MID%, MID#,PDW, MPV, PCT, RCDW, LCDW, RDW, P-LCR and WBC, RBC, PLT |
three histograms | |
Principal | Electronic impedance, SFT method for hemoglobin |
Throughput | ≥60T/H |
Analysis Mode | Optional venous blood, anticoagulant blood and prediluted blood |
Sample Volume | Anticoagulant whole blood≤9.6μL, Anticoagulant capillary blood ≤9.6μL, prediluted capillary blood≤20μL, the sample volume for |
repeating two times testing and avoiding second sampling | |
Block-clearing: | Soak and washing back and forth, high pressure burning. Boast the function of monitoring incomplete blockage |
Working Mode: | Automatic sampling, detecting automatic testing, furnished with dilutor, no need diluting outside. Automatic dispensing lyse and |
making second diluting automatically | |
Alarm | Automated system diagnosis, self testing, fault alarm and reagent shortage alarm |
Standby Protection | 24 hours switch on, automatic sleep and wake up function |