MeCan Medical Best Quality Medical Equipment Digital X Ray Machine High Frequency Manual X-ray Factory,Every equipments from MeCan gets passed strict quality inspection,and final passed yield is 100%. High-frequency power meets all kinds of large volume, thick position radiography. High-voltage generator outputs more stable kV. Large-heat capacity of X-ray tube supports long time and large dose of continuous working. Fast anode rotation ensures great heat dissipation and long service life. If you need more details, please send us inquiry in time.
Availability: | |
---|---|
Quantity: | |
Medical Equipment Digital X Ray Machine High Frequency Electric Manual X-ray
Model: MX-DR500A10
1.15.4 inch HQ LCD touch screen, real-time display for the tube rotation angle
2.Preseted parameters for 14 human body parts
3.KV, mA, S adjustable on the screen
4.OEM/ODM supported
5.Tube angle: 360° rotable
6.Up & down tube movement available
7.Left & right movement for both the column and the bucky
8.Extra long floor rail of 2.1M long, mobile tube column & table board to get easier examination for lower limbs
9.Only 5.5 cm between the table board and the detector for better image
10.Mobile table board in 4 directions controlled by foot switch
11.Separable column and bucky
12.Adjustable SID from 180cm for adults to 150cm for children
13.Space-saving design for installation in rooms of only 3M wide
14.Easy to install, only 3 hours needed for installing the whole machine
15.Manual brake system for adjusting the chest stand and the tube to any height needed
16.Only 2 minutes needed to exam 1 patient
17.All ports connected (as above)
18.Remote service 7*24 hours
Parameter of digital x ray machine:
Model | MX-320A10 | MX-500A10 | MX-650B10 |
Power | 32kW | 50kW | 65kW |
Power supply | 50HZ,60HZ, wire diameter >4mm2, internal resistance<0.5Ω; 20/32/50kW(single phase 220V /two-phase 380V available), 65kW(only 380V) | ||
mA | 10-400mA | 10-630mA | 10-800mA |
mAs | 0.4-320mAs | 0.4-1000mAs | 0.4-1000mAs |
KV | 40-125kV 1kV step | 40-150kV 1kV step | |
Exposure time | 1ms~10000ms | ||
Focus size | Default 0.6*0.6mm/1.2*1.2mm dual focus, toshiba (option) | ||
Anode rotating speed/Anode heat capacity | 2800prm/ 1300kHU | 8400prm/1300kHU | |
Generator frequency | 30kHZ/200kHZ(option) | ||
Radiography table(W*L cm) | 73cm(W)*200cm(L), Move 74cm left and right, 20cm back and front | ||
Flat Panel Detector | |||
Image size | 17*17 inch (14*17 for (option) | ||
Pixels Matrix | 140μm | ||
A/D Conversion | 16bits | ||
Spatial Resolution | 3.6 Lp/mm | ||
Software | Professional Software | ||
Computer | CPU: I5, 8G memory, 1T solid state drive, 2 pcs Gigabit network card |
More test images of medical x ray equipment:
Size of our 32kW /50kW /65kW Digital X Ray Machine
Medical Equipment Digital X Ray Machine High Frequency Electric Manual X-ray
Model: MX-DR500A10
1.15.4 inch HQ LCD touch screen, real-time display for the tube rotation angle
2.Preseted parameters for 14 human body parts
3.KV, mA, S adjustable on the screen
4.OEM/ODM supported
5.Tube angle: 360° rotable
6.Up & down tube movement available
7.Left & right movement for both the column and the bucky
8.Extra long floor rail of 2.1M long, mobile tube column & table board to get easier examination for lower limbs
9.Only 5.5 cm between the table board and the detector for better image
10.Mobile table board in 4 directions controlled by foot switch
11.Separable column and bucky
12.Adjustable SID from 180cm for adults to 150cm for children
13.Space-saving design for installation in rooms of only 3M wide
14.Easy to install, only 3 hours needed for installing the whole machine
15.Manual brake system for adjusting the chest stand and the tube to any height needed
16.Only 2 minutes needed to exam 1 patient
17.All ports connected (as above)
18.Remote service 7*24 hours
Parameter of digital x ray machine:
Model | MX-320A10 | MX-500A10 | MX-650B10 |
Power | 32kW | 50kW | 65kW |
Power supply | 50HZ,60HZ, wire diameter >4mm2, internal resistance<0.5Ω; 20/32/50kW(single phase 220V /two-phase 380V available), 65kW(only 380V) | ||
mA | 10-400mA | 10-630mA | 10-800mA |
mAs | 0.4-320mAs | 0.4-1000mAs | 0.4-1000mAs |
KV | 40-125kV 1kV step | 40-150kV 1kV step | |
Exposure time | 1ms~10000ms | ||
Focus size | Default 0.6*0.6mm/1.2*1.2mm dual focus, toshiba (option) | ||
Anode rotating speed/Anode heat capacity | 2800prm/ 1300kHU | 8400prm/1300kHU | |
Generator frequency | 30kHZ/200kHZ(option) | ||
Radiography table(W*L cm) | 73cm(W)*200cm(L), Move 74cm left and right, 20cm back and front | ||
Flat Panel Detector | |||
Image size | 17*17 inch (14*17 for (option) | ||
Pixels Matrix | 140μm | ||
A/D Conversion | 16bits | ||
Spatial Resolution | 3.6 Lp/mm | ||
Software | Professional Software | ||
Computer | CPU: I5, 8G memory, 1T solid state drive, 2 pcs Gigabit network card |
More test images of medical x ray equipment:
Size of our 32kW /50kW /65kW Digital X Ray Machine