MeCan Medical Best Blood SerumElectrolyte AnalyzerMachine Supplier,More than 20000 customers choose MeCan. MeCan provide one-stop solutions for new hospitals, clinics, labs, and universities, has helped 270 hospitals,540 clinics,190 vet clinics to set up in Malaysia, Africa, Europe, etc. we can save your time, energy and money.
Quantity: |
---|
Open System Blood Serum Electrolyte Analyzer Machine With TCO2
Main Features:
1. 7” Color touch screen, easy to operate
2. High accurate and long life electrode and TCO2 sensor
3. Programmable multi-format print-out
4. Reagent pack, real time monitoring of reagent residual volume
5. Up to 50,000 test results can be stored
6. RS-232 port, supporting bar code reader and USB interface
7. Sleep mode to reduce reagent consumption
8. Human-machine interactive menu; Dynamic and real-time display of sample ID.
9. Liquid level automatic detection and alarming. Real-time diagnostic of system working status.
10. Automatically detect and filter tiny bubbles to avoid clog and ensure accurate measurement.
11. Wave theory flushing method and direct flushing pipe method to avoid block and crossed contamination.
12. Automatic calibration and two-point correction to adjust slope and intercept; Available to print-out QC graph and QC statistical parameters.
13. Power failure protection to avoid data losing. Data storage could be extended to more than 50000. Supporting fuzzy query.
14. Supporting LIS software; Upload data format is selectable; Supporting RTC Clock management.
15. Available to power off any time, therefore reduce reagent consumption, suitable for any hospitals.
Working environment
Temperature: 5-40℃
Relative Humidity: ≤ 80 %
Atmospheric pressure: (86~106) kPa
Power supply: AC220V±22V, 50Hz±1Hz
Power: ≤120W
Dimension: 340mm*200mm*380mm
Net weight: 6Kg
Items | Measuring Range | Resolution | Measuring Precision |
(CV%) | |||
K+ | 0.5-20.0mmol/L | 0.01 mmol/L | ≤1.0% |
Na+ | 15-200mmol/L | 0.1 mmol/L | ≤1.0% |
Cl- | 15-200mmol/L | 0.1 mmol/L | ≤1.0% |
Ca2+ | 0.1-6.0mmol/L | 0.01 mmol/L | ≤1.0% |
Li+ | 0.1-5.0mmol/L | 0.01 mmol/L | ≤2.0% |
pH | 4-9pH | 0.01 pH | ≤0.5% |
TCO2 | 2.0-70.0mmol/L | 0.1 mmol/L | ≤3.0% |
Option | Sample tray |
Option: Sample tray
More Pictures
Parameter configuration
A K, Na, Cl
B K, Na, Cl, TCO2
C K, Na, Cl, iCa, nCa, TCa, pH
D K, Na, Cl, iCa, nCa, TCa, pH, TCO2, AG
F K, Na, Cl, Li
H K, Na, Cl, iCa, nCa, TCa, pH, Li
I K, Na, Cl, iCa, nCa, TCa, pH, Li, TCO2, AG
J K, Na, Cl, Mg
K K, Na, Cl, iCa, nCa, TCa, pH, Mg
L K, Na, Cl, iCa, nCa, TCa, pH, Mg, TCO2, AG
M K, Na, Cl, iCa, nCa, TCa, pH, Li, Mg, TCO2, AG
Specification
Sample: serum, plasma, whole blood, cerebrospinal fluid and dilute urine
Analysis Method: ion selective electrode (ISE)
Measuring speed: ≤25s
Sample volume: 60-300ul (item 3 to item 11)
Sample position: 39 positions (including 5 emergency and 2 QC)
Storage: up to 10000 test results
Printer: Internal thermal printer
Interface: RS232 port
impresses customers with its appearance and thorough workmanship.
Open System Blood Serum Electrolyte Analyzer Machine With TCO2
Main Features:
1. 7” Color touch screen, easy to operate
2. High accurate and long life electrode and TCO2 sensor
3. Programmable multi-format print-out
4. Reagent pack, real time monitoring of reagent residual volume
5. Up to 50,000 test results can be stored
6. RS-232 port, supporting bar code reader and USB interface
7. Sleep mode to reduce reagent consumption
8. Human-machine interactive menu; Dynamic and real-time display of sample ID.
9. Liquid level automatic detection and alarming. Real-time diagnostic of system working status.
10. Automatically detect and filter tiny bubbles to avoid clog and ensure accurate measurement.
11. Wave theory flushing method and direct flushing pipe method to avoid block and crossed contamination.
12. Automatic calibration and two-point correction to adjust slope and intercept; Available to print-out QC graph and QC statistical parameters.
13. Power failure protection to avoid data losing. Data storage could be extended to more than 50000. Supporting fuzzy query.
14. Supporting LIS software; Upload data format is selectable; Supporting RTC Clock management.
15. Available to power off any time, therefore reduce reagent consumption, suitable for any hospitals.
Working environment
Temperature: 5-40℃
Relative Humidity: ≤ 80 %
Atmospheric pressure: (86~106) kPa
Power supply: AC220V±22V, 50Hz±1Hz
Power: ≤120W
Dimension: 340mm*200mm*380mm
Net weight: 6Kg
Items | Measuring Range | Resolution | Measuring Precision |
(CV%) | |||
K+ | 0.5-20.0mmol/L | 0.01 mmol/L | ≤1.0% |
Na+ | 15-200mmol/L | 0.1 mmol/L | ≤1.0% |
Cl- | 15-200mmol/L | 0.1 mmol/L | ≤1.0% |
Ca2+ | 0.1-6.0mmol/L | 0.01 mmol/L | ≤1.0% |
Li+ | 0.1-5.0mmol/L | 0.01 mmol/L | ≤2.0% |
pH | 4-9pH | 0.01 pH | ≤0.5% |
TCO2 | 2.0-70.0mmol/L | 0.1 mmol/L | ≤3.0% |
Option | Sample tray |
Option: Sample tray
More Pictures
Parameter configuration
A K, Na, Cl
B K, Na, Cl, TCO2
C K, Na, Cl, iCa, nCa, TCa, pH
D K, Na, Cl, iCa, nCa, TCa, pH, TCO2, AG
F K, Na, Cl, Li
H K, Na, Cl, iCa, nCa, TCa, pH, Li
I K, Na, Cl, iCa, nCa, TCa, pH, Li, TCO2, AG
J K, Na, Cl, Mg
K K, Na, Cl, iCa, nCa, TCa, pH, Mg
L K, Na, Cl, iCa, nCa, TCa, pH, Mg, TCO2, AG
M K, Na, Cl, iCa, nCa, TCa, pH, Li, Mg, TCO2, AG
Specification
Sample: serum, plasma, whole blood, cerebrospinal fluid and dilute urine
Analysis Method: ion selective electrode (ISE)
Measuring speed: ≤25s
Sample volume: 60-300ul (item 3 to item 11)
Sample position: 39 positions (including 5 emergency and 2 QC)
Storage: up to 10000 test results
Printer: Internal thermal printer
Interface: RS232 port