Availability: | |
---|---|
Quantity: | |
MCX0021
MeCan
Technical Data HD Hemodialysis Machine
Model:MCX0021
The HD Hemodialysis Machine is a state-of-the-art medical device designed for effective renal replacement therapy. Engineered with advanced technology and precision, this machine provides efficient dialysis treatment in both clinical and home settings, ensuring optimal patient outcomes and comfort during therapy.
More Details:
Main performance of this device:
1. Self-checking function;
2. Carbonate dialysis;
3. Double needle dialysis;
4. Liquid level detector;
5. Bubble detector;
6. Blood leakage detector;
7. Temperature and electric conductivity monitoring;
8. Arterial pressure, venous pressure and transmembrane pressure monitoring;
9. Rolling blood pump;
10. Heparin pump;
11. Dehydration amount controlled by capacity;
12. Automatic disinfection cleaning program;
13. Stand-by power of blood pump in case of power failure;
14. Information display function of display screen.
Parameters:
General data:
Dimensions :1380 x 380 x 400 mm (H x W x D);
Weight approx. :88 KG;
Water supply:
Water inlet pressure :1.5-6.0 bar
Water inlet temperature :5℃~32℃
Max. drain height :1m
Concentrate supply
Supply pressure : 0 to 2 m suction height
Electrical data
Power supply:AC220V±10%, 47-63HZ
Current consumption:max. max. 10 A
Extracorporeal circuit
Arterial pressure monitoring
Display range: -380 mmHg to +400 mmHg
Accuracy :±10 mmHg
Resolution :1 mmHg
Venous pressure monitoring
Display range: -180 mmHg to +600 mmHg
Accuracy :±10 mmHg
Resolution :1 mmHg
Transmembrane pressure monitoring
Display range :-180 mmHg to +600 mmHg
Accuracy :±20 mmHg
Resolution :1 mmHg
Arterial blood pump
Blood flow range :30 to 600ml/min in 8 mm bloodline systems
Accuracy :±10%
Air bubble pump
By ultrasound transmission, additional optical monitoring in venous clamp.
Heparin pump:
Delivery range: 0ml/h to 10ml/h
Bolus function max. :20 mL per bolus
Syringe size :10, 20, 30, 50ml
Dialysis fluid circuit
Dialysis fluid flow range
Selectable :100-800 mL/min
Dialysis fluid temperature
Selectable :34.0℃ to 40.0℃
Dialysis fluid conductivity
Range: 12 to 16 mS/cm (25℃)
Accuracy :±0.1 mS/cm
Acid concentration dialysis fluid
Default mixing ratio :1+34 (others possible)
Range :125 to 150 mmol/L
Bicarbonate concentration dialysis fluid
Default mixing ratio :1+27.6 (others possible)
Range :-8 to +8 mmol/L bicarbonate
Ultrafiltration
UF rate :0ml/h~4000ml/h
Accuracy :±1%
Allowed dialyzer UF factor :unlimited
Parameter displayed :UF goal, UF time, UF rate, UF volume
Blood leak detector
Sensitivity :≤0.35 mL blood/min (HCT=32)
KT/V
Calculation
Disinfection and cleaning programs
Rinse
Temperature/flow :30 to 60℃ / 300 to 800ml/min
Hot Rinse (recirculation)
Temperature/flow :30 to 85℃ / 300 to 800ml/min
Hot disinfection with chemical
Temperature/flow :30 to 85℃/ 300 to 800ml/min
Various program combination selectable
Technical Data-Options
Blood pressure Monitor (BPM) (optional function)
Display range Systole: 40-280 mmHg
Diastole: 40-280 mmHg
Accuracy: 1 mmHg
Central Delivery system for acid conc.
Supply pressure :0 to 100 mbar, 1 m suction height with Central delivery system: 0-500 mbar
Endotoxin filter-- Dialysis fluid filter system (optional function)
Balancing accuracy :±0.1% of dialysate flow
Bicarbonate dry
Concentrate :Bi-cart (optional function)
Technical Data HD Hemodialysis Machine
Model:MCX0021
The HD Hemodialysis Machine is a state-of-the-art medical device designed for effective renal replacement therapy. Engineered with advanced technology and precision, this machine provides efficient dialysis treatment in both clinical and home settings, ensuring optimal patient outcomes and comfort during therapy.
More Details:
Main performance of this device:
1. Self-checking function;
2. Carbonate dialysis;
3. Double needle dialysis;
4. Liquid level detector;
5. Bubble detector;
6. Blood leakage detector;
7. Temperature and electric conductivity monitoring;
8. Arterial pressure, venous pressure and transmembrane pressure monitoring;
9. Rolling blood pump;
10. Heparin pump;
11. Dehydration amount controlled by capacity;
12. Automatic disinfection cleaning program;
13. Stand-by power of blood pump in case of power failure;
14. Information display function of display screen.
Parameters:
General data:
Dimensions :1380 x 380 x 400 mm (H x W x D);
Weight approx. :88 KG;
Water supply:
Water inlet pressure :1.5-6.0 bar
Water inlet temperature :5℃~32℃
Max. drain height :1m
Concentrate supply
Supply pressure : 0 to 2 m suction height
Electrical data
Power supply:AC220V±10%, 47-63HZ
Current consumption:max. max. 10 A
Extracorporeal circuit
Arterial pressure monitoring
Display range: -380 mmHg to +400 mmHg
Accuracy :±10 mmHg
Resolution :1 mmHg
Venous pressure monitoring
Display range: -180 mmHg to +600 mmHg
Accuracy :±10 mmHg
Resolution :1 mmHg
Transmembrane pressure monitoring
Display range :-180 mmHg to +600 mmHg
Accuracy :±20 mmHg
Resolution :1 mmHg
Arterial blood pump
Blood flow range :30 to 600ml/min in 8 mm bloodline systems
Accuracy :±10%
Air bubble pump
By ultrasound transmission, additional optical monitoring in venous clamp.
Heparin pump:
Delivery range: 0ml/h to 10ml/h
Bolus function max. :20 mL per bolus
Syringe size :10, 20, 30, 50ml
Dialysis fluid circuit
Dialysis fluid flow range
Selectable :100-800 mL/min
Dialysis fluid temperature
Selectable :34.0℃ to 40.0℃
Dialysis fluid conductivity
Range: 12 to 16 mS/cm (25℃)
Accuracy :±0.1 mS/cm
Acid concentration dialysis fluid
Default mixing ratio :1+34 (others possible)
Range :125 to 150 mmol/L
Bicarbonate concentration dialysis fluid
Default mixing ratio :1+27.6 (others possible)
Range :-8 to +8 mmol/L bicarbonate
Ultrafiltration
UF rate :0ml/h~4000ml/h
Accuracy :±1%
Allowed dialyzer UF factor :unlimited
Parameter displayed :UF goal, UF time, UF rate, UF volume
Blood leak detector
Sensitivity :≤0.35 mL blood/min (HCT=32)
KT/V
Calculation
Disinfection and cleaning programs
Rinse
Temperature/flow :30 to 60℃ / 300 to 800ml/min
Hot Rinse (recirculation)
Temperature/flow :30 to 85℃ / 300 to 800ml/min
Hot disinfection with chemical
Temperature/flow :30 to 85℃/ 300 to 800ml/min
Various program combination selectable
Technical Data-Options
Blood pressure Monitor (BPM) (optional function)
Display range Systole: 40-280 mmHg
Diastole: 40-280 mmHg
Accuracy: 1 mmHg
Central Delivery system for acid conc.
Supply pressure :0 to 100 mbar, 1 m suction height with Central delivery system: 0-500 mbar
Endotoxin filter-- Dialysis fluid filter system (optional function)
Balancing accuracy :±0.1% of dialysate flow
Bicarbonate dry
Concentrate :Bi-cart (optional function)