MeCan Medical Best Quality Vest airway clearance system device Factory,Every equipments from MeCan gets passed strict quality inspection,and final passed yield is 100%, we are in it more than 15 years, we are very professional and we will provide the best service to you.
Quantity: | |
---|---|
Place of Origin:CN;GUA
Instrument classification:Class II
Brand Name:Mecan
Model Number:MCL-717A
Using high frequency of chest wall oscillation to eliminate sputum of respiratory airway. It is suitable for patients who have difficulty in pulmonary secretion excretion or that have pulmonary atelectasis caused by mucus obstruction. It would facilitate airway and improve bronchial drainage.
Structure:standard cabinet cart type(inseparable)
Display: 9.7 inch colorful LCD touch screen, English menu.
1. ABS engineering plastics with strong corrosion resistance.
2. 9.7 inch color touch screen for MCL-8000A, 5 inch color touch screen for MCL-8000B.
3. Manual mode, 5 automatic program modes and user-defined mode, making operation professional, flexible and convenient.
4. Equipped with handheld pressure relief device. When patients feel uncomfortable, they can push it to release pressures, convenient and safe.
5. Automatic alarm after the end of the treatment.
6. Equipped with 3 different vests and chest belts, meet different requirements of patients
7. Vest is made up of jacket and air bag. They are detachable for easily cleaning.
Prout name | Vest airway clearance system |
Model | MCL- 717A |
Environment temperature | 5°C-40°C |
Relative humidity | 30%-85% |
Power voltage | 220V±10% |
Frequency | 50Hz±1Hz |
Pressure in treatment: | gear Pressure adjustable range 0.5Kpa--3.2 Kpa |
Working mode | anual mode, five automatic modes and user-defined mode. |
Timing Function | automatic mode timing 5min-20min, manual mode timing 1min-99min, step is 1min. |
Normal working noises: | ≤50dB |
Structure and working principle diagram
MCL-717A holothoracic multifrequency vibratory sputum excretion machine is composed of host machine, hand control ball, gas guiding hose and pneumatic vest.
Gas guiding hose applies PVC material. Pneumatic vest applies TPU high strength composite fabric.
Pneumatic vests are divided into standard holothoracic pneumatic vest and simple hemi-thoracic pneumatic chest strap.
Vest sizes: (Unit: mm)
Standard configuration: 3 standard holothoracic pneumatic vests, 3 simple hemithoracic pneumatic chest straps
Size of Adult Vest | 1450 * 640 | 1300* 640 | 1020* 640 |
Size of Child Vest | 946*600 | 827*526 | 737*472 |
Size of Adult Chest Strap | 1350*200 | 1120*200 | 920*200 |
Size of Child Chest Strap | 800*180 | 650*180 | 500*180 |
Place of Origin:CN;GUA
Instrument classification:Class II
Brand Name:Mecan
Model Number:MCL-717A
Using high frequency of chest wall oscillation to eliminate sputum of respiratory airway. It is suitable for patients who have difficulty in pulmonary secretion excretion or that have pulmonary atelectasis caused by mucus obstruction. It would facilitate airway and improve bronchial drainage.
Structure:standard cabinet cart type(inseparable)
Display: 9.7 inch colorful LCD touch screen, English menu.
1. ABS engineering plastics with strong corrosion resistance.
2. 9.7 inch color touch screen for MCL-8000A, 5 inch color touch screen for MCL-8000B.
3. Manual mode, 5 automatic program modes and user-defined mode, making operation professional, flexible and convenient.
4. Equipped with handheld pressure relief device. When patients feel uncomfortable, they can push it to release pressures, convenient and safe.
5. Automatic alarm after the end of the treatment.
6. Equipped with 3 different vests and chest belts, meet different requirements of patients
7. Vest is made up of jacket and air bag. They are detachable for easily cleaning.
Prout name | Vest airway clearance system |
Model | MCL- 717A |
Environment temperature | 5°C-40°C |
Relative humidity | 30%-85% |
Power voltage | 220V±10% |
Frequency | 50Hz±1Hz |
Pressure in treatment: | gear Pressure adjustable range 0.5Kpa--3.2 Kpa |
Working mode | anual mode, five automatic modes and user-defined mode. |
Timing Function | automatic mode timing 5min-20min, manual mode timing 1min-99min, step is 1min. |
Normal working noises: | ≤50dB |
Structure and working principle diagram
MCL-717A holothoracic multifrequency vibratory sputum excretion machine is composed of host machine, hand control ball, gas guiding hose and pneumatic vest.
Gas guiding hose applies PVC material. Pneumatic vest applies TPU high strength composite fabric.
Pneumatic vests are divided into standard holothoracic pneumatic vest and simple hemi-thoracic pneumatic chest strap.
Vest sizes: (Unit: mm)
Standard configuration: 3 standard holothoracic pneumatic vests, 3 simple hemithoracic pneumatic chest straps
Size of Adult Vest | 1450 * 640 | 1300* 640 | 1020* 640 |
Size of Child Vest | 946*600 | 827*526 | 737*472 |
Size of Adult Chest Strap | 1350*200 | 1120*200 | 920*200 |
Size of Child Chest Strap | 800*180 | 650*180 | 500*180 |