MeCan Medical Best X-ray Dosimeter Factory Price - MeCan Medical,OEM/ODM, customized according to your requirements. MeCan provide one-stop solutions for new hospitals, clinics, labs, and universities, has helped 270 hospitals,540 clinics,190 vet clinics to set up in Malaysia, Africa, Europe, etc. we can save your time, energy and money.
Availability: | |
---|---|
Quantity: | |
Detector | GM counting tube |
Display | 4-digit LCD |
Measuring Range | Accumulated dose equivalent: Hp(10)0.0μSv-99.99mSv Dose equivalent rate :Hp(10)0.1μSv/h-99.99mSv/h |
Measuring Time | <6.0μSv/h 36s >6μSv/h ≤3.6s |
Dose Rate Response | |
Energy Response | |
Relative Error | 137Cs) |
Alarm Function | Within the measuring range, can initialize the alarm threshold value for the dose rate and the accumulated dose. This instrument has a fixed alarm threshold value. When the accumulated dose adds 0.1μSv every time, it will give a sound and a flash. When the accumulated dose≥50μSv the sound and flash will last for 5s, at the same time there will show the word of“ALARM”. When the dose equivalent rate ≥25μSv/h,the sound and flash will last for about 6s,“ALARM”will appear. When the counting tube is blocked, the alarm will continue and not stop, and the “ALARM” will appear. The intensity of the alarm sound: about 80dB at 30cm away. |
Undervoltage Indication | When the voltage of the battery |
Power Consumption | Two AAA 1.5V alkali batteries(7# battery).The power consumption |
Exterior Size | 55(W)x 92(L)x 18(T) |
Detector | GM counting tube |
Display | 4-digit LCD |
Measuring Range | Accumulated dose equivalent: Hp(10)0.0μSv-99.99mSv Dose equivalent rate :Hp(10)0.1μSv/h-99.99mSv/h |
Measuring Time | <6.0μSv/h 36s >6μSv/h ≤3.6s |
Dose Rate Response | |
Energy Response | |
Relative Error | 137Cs) |
Alarm Function | Within the measuring range, can initialize the alarm threshold value for the dose rate and the accumulated dose. This instrument has a fixed alarm threshold value. When the accumulated dose adds 0.1μSv every time, it will give a sound and a flash. When the accumulated dose≥50μSv the sound and flash will last for 5s, at the same time there will show the word of“ALARM”. When the dose equivalent rate ≥25μSv/h,the sound and flash will last for about 6s,“ALARM”will appear. When the counting tube is blocked, the alarm will continue and not stop, and the “ALARM” will appear. The intensity of the alarm sound: about 80dB at 30cm away. |
Undervoltage Indication | When the voltage of the battery |
Power Consumption | Two AAA 1.5V alkali batteries(7# battery).The power consumption |
Exterior Size | 55(W)x 92(L)x 18(T) |