MeCan Medical Professional On-Line HDF Hemodiafiltration Machine HDF Machine Hemodialysis Machine HD Machine manufacturers, Our Hemodialyse Machine with excellent quality and advanced technology, tested by market and end users, are popular in both domestic and foreign makets, which have been sold to more than 100 cities in Countries and 90 countries and district such as Middle East, Southeast Asia, South America and Afica etc.
We are going to make every single effort for being excellent and excellent, and accelerate our ways for standing while in the rank of international top-grade and high-tech enterprises for We welcome you to join us in this path of creating a prosperous and efficient business together.
On-Line HDF Hemodiafiltration Machine HDF Machine Hemodialysis Machine HD Machine
Model: MC-HDF
Features:
1 | Intelligent operation system |
2 | Easy operation with visual and audio alarms |
3 | Multi-purpose service/maintenance interface |
4 | Profiling: sodium concentration and UF curve |
Main performance of our HDF Machine:
1.On-line HDF
2.Self-checking function
3.Carbonate dialysis
4.Double needle dialysis
5.Liquid level detector
6.Bubble detector
7.Blood leakage detector
8.Temperature and electric conductivity monitoring
9.Arterial pressure, venous pressure and transmembrane pressure monitoring
10.Rolling blood pump
11.Heparin pump
12.Dehydration amount controlled by capacity
13.Automatic disinfection cleaning program
14.Stand-by power of blood pump in case of power failure
15.Information display function of display screen
Technical Parameter
Size & Weight:
Size: 380mmx400x1380mm (L*W*H);
Area: 500*520mm;
Weight: 88KG;
Power supply:
AC220V, 50Hz/60Hz, 10A
Input power: 1500W
Back-up battery: 30 minutes
Working Condition:
Water input pressure: 0.1Mpa~0.6Mpa, 15P.S.I~60P.S.I
Water input temperature: 5℃~30℃
Working environment temperature: 10℃~30℃ at relative humidity ≦70%
UF rate:
Flow range: 0ml/h~4000ml/h
Resolution ratio: 1ml
Precision: ±30ml/h
Blood pump & substitution pump:
Blood pump flow range: 30ml/min~600ml/min (diameter: 8mm or 6mm)
Substitution pump flow range: 30ml/min~600ml/min (diameter 8mm or 6mm)
Resolution ratio: 0.1ml
Precision: ±10ml or 10% of reading
Heparin pump:
Syringe size: 20, 30, 50ml
Flow range: 0ml/h~10ml/h
Resolution ratio: 0.1ml
Precision: ±5%
Monitoring system & Alarm setup:
Venous pressure: -180mmHg ~ +600mmHg, ±10mmHg
Arterial pressure: -380mmHg ~ +400mmHg, ±10mmHg
TMP: -180mmHg ~ +600mmHg, ±20mmHg
Dialysate temperature: preset range 34.0℃~39.0℃
Dialysate flow: Less than 800 ml/min (Adjustable)
Substitution flow range: 0-28 L/H (on line HDF)
Blood leak detection: Photo chromic alarm when erythrocyte specific volume is 0.32±0.02 or blood leak volume is equal or more than 1ml per liter of dialysate.
Bubble detection: Ultrasonic, Alarm when a single air bubble volume is more than 200μl at 200ml/min blood flow
Conductivity: Acoustic-optic
Disinfection/Sanitize:
1. Hot disinfection:
Time: 30 minutes; Temperature: about 80℃, at flow rate 500ml/min;
2.Chemical disinfection:
Time: 30minutes, Temperature: about 36℃~50℃, at flow rate 500ml/min;
3.Chemical disinfection with heat:
Time: 45minutes, Temperature: about 36℃~80℃, at flow rate 50ml/min;
4.Rinse:
Time: 10minutes, Temperature: about 37℃, at flow rate 800ml/min;
Storage Environment:
Storage temperature should be between 5℃~40℃, at relative humidity ≦80%
Air bubble monitor
Infrared and response threshold value:Single air bubble of 200u I exists when Blood flux is 200ml/min
Inflow pressure:0MPa~0.6MPa
Inflow temperature: 5ºC~30ºC
Environment temperature: 10ºC~30ºC, Relative humidity≤70%
Rinse/disinfection: chemical disinfection (citric acid,peracetic acid and oxalic acid)
Hot rinse: 80ºC
Back-up power supply: last for 15-30min after electric-cut.
Pyrogen filter port
Completely filtrating the remained bacteria and endotoxin.(optional)
Net connection
One computer can audit and control the treatment of maximum 20 units hemodialysis machine (optional)
Automatic Cleaning Function of MeCan Hemodialysis Machine
Our hemodialysis machine has an automatic cleaning function. After dialysis each time, if you click Disinfect, the machine will automatically disinfect, after disinfection, it will automatically shut down, or click Selftest, the machine will automatically disinfect and selftest, after it, the machine can be used by the second person.It can ensure safety used by between different patients. Please click the picture to see the video.
One stop solution for hemodialysis from MeCan Medical
More pictures of our Hemodialysis Machine
Our hemodialysis machine for kidney in different hospitals worldwide, Paraguay, Nigeria, South Africa, Zimbabwe, Uganda, Kenya, Malaysia etc, more than 90 countries and districts.
Our hemodialysis machine in Paraguay
Our hemodialysis HD machine in Nigeria
Our hemodialysis machine in Uganda
Our hemodialysis HD machine in Kenya
Our hemodialysis machine in Zimbabwe
Our hemodialysis system in South Africa
Our hemodialysis machine in Malaysia
Tests and analyzed data show that the performance of this product can meet the needs of customers.
That has a sound business credit history, outstanding after-sales service and modern producing facilities, we have earned an superb popularity amid our buyers across the planet for custom spectrophotometer company, The product will supply to all over the world, such as: European, Suriname, Corporate goal: Customers' satisfaction is our goal, and sincerely hope to establish long-terms stable cooperative relations with customers to jointly develop the market. Building brilliant tomorrow together!Our company regards "reasonable prices, efficient production time and good after-sales service" as our tenet. We hope to cooperate with more customers for mutual development and benefits. We welcome potential buyers to contact us.