With features such as adjustable flow rates, multiple infusion modes, and a user-friendly interface, the Medical Intravenous Infusion Pump offers healthcare professionals the flexibility.
Availability: | |
---|---|
Quantity: | |
MCS0935
MeCanMed
Medical Intravenous Infusion Pump
Model:MCS0935
With features such as adjustable flow rates, multiple infusion modes, and a user-friendly interface, the Medical Intravenous Infusion Pump offers healthcare professionals the flexibility and control they need to provide optimal care to their patients.
Features:
Classic heritage
Meet the core needs of infusion
Dual-CPU design,more safe and reliable system operation
Rolling spin design,easy to operate
Optional accessories,upgrade calibration free function
Specifications:
Model Performance | MCS0935 |
Infusion Rate range(ml/h) | 1-1200; 1.0ml/h~99.9ml/h range adjustable in 0.1ml/h steps or 1ml/h steps ; 100.0ml/h~1200ml/h range adjustable in 1ml/h steps only |
Infusion precision | ±5% ; (When correctly calibrated and operated in a stable environment) |
Pre-set of infusion volume | 0-9999 ml, 1ml steps |
Infusion volume accuracy | ±5% ; (When correctly calibrated and operated in a stable environment) |
Bolus rate(ml/h)and accuracy | 200~1200,adjustable, default ±20% ; |
Max. pressure | > 120kPa |
Occlusion alarm level | 50KPa±25KPa |
KVO Rate | KVO rate 3ml/h , flow rate>10ml/h ; KVO rate 1ml/h, 1ml/h <flow rate≤10ml/h |
Recoverable alarm time | 1 min 50 s ~ 2 min |
Pause overtime alarm time | 1 min 50 s ~ 2 min |
Bubble sensitivity | Detectability of air bubble >50uL |
Alarm | Air in line, Occlusion, Door Open, Complete infusion, Low Power, Battery Exhausted, Motor Failure, Low Temperature, Pause Overtime etc. |
Power | a.c.100-240V 50/60 Hz |
AC | 40 VA |
Gross Weight | 2.5kg |
Classification | Type CF, Class I , IPX1 |
Size | 165mm(L)×120mm(W)×220mm(H) |
Operation Conditions | Operating Temperature: +5℃~+40℃ |
Relative Humidity: 20%~90% | |
Atmospheric pressure: 70KPa~106KPa | |
Infusion pump should be operated in conditions free from strong shocks or vibrations, strong magnetic fields or corrosive gas environments. | |
Environmental temperature for Charging battery | Environmental Temperature: -20℃~+60℃
|
Service life | 5 years |
Medical Intravenous Infusion Pump
Model:MCS0935
With features such as adjustable flow rates, multiple infusion modes, and a user-friendly interface, the Medical Intravenous Infusion Pump offers healthcare professionals the flexibility and control they need to provide optimal care to their patients.
Features:
Classic heritage
Meet the core needs of infusion
Dual-CPU design,more safe and reliable system operation
Rolling spin design,easy to operate
Optional accessories,upgrade calibration free function
Specifications:
Model Performance | MCS0935 |
Infusion Rate range(ml/h) | 1-1200; 1.0ml/h~99.9ml/h range adjustable in 0.1ml/h steps or 1ml/h steps ; 100.0ml/h~1200ml/h range adjustable in 1ml/h steps only |
Infusion precision | ±5% ; (When correctly calibrated and operated in a stable environment) |
Pre-set of infusion volume | 0-9999 ml, 1ml steps |
Infusion volume accuracy | ±5% ; (When correctly calibrated and operated in a stable environment) |
Bolus rate(ml/h)and accuracy | 200~1200,adjustable, default ±20% ; |
Max. pressure | > 120kPa |
Occlusion alarm level | 50KPa±25KPa |
KVO Rate | KVO rate 3ml/h , flow rate>10ml/h ; KVO rate 1ml/h, 1ml/h <flow rate≤10ml/h |
Recoverable alarm time | 1 min 50 s ~ 2 min |
Pause overtime alarm time | 1 min 50 s ~ 2 min |
Bubble sensitivity | Detectability of air bubble >50uL |
Alarm | Air in line, Occlusion, Door Open, Complete infusion, Low Power, Battery Exhausted, Motor Failure, Low Temperature, Pause Overtime etc. |
Power | a.c.100-240V 50/60 Hz |
AC | 40 VA |
Gross Weight | 2.5kg |
Classification | Type CF, Class I , IPX1 |
Size | 165mm(L)×120mm(W)×220mm(H) |
Operation Conditions | Operating Temperature: +5℃~+40℃ |
Relative Humidity: 20%~90% | |
Atmospheric pressure: 70KPa~106KPa | |
Infusion pump should be operated in conditions free from strong shocks or vibrations, strong magnetic fields or corrosive gas environments. | |
Environmental temperature for Charging battery | Environmental Temperature: -20℃~+60℃
|
Service life | 5 years |