PRODUCT DETAIL
You are here: Home » Products » ICU Equipment » Ventilator » ICU Ventilators with Compressor ICU Respirator Factory

loading

ICU Ventilators with Compressor ICU Respirator Factory

MCS0151 is professional for COVID-19 treatment, can be used in respiratory management of after anesthesia operation, ambulance room, ICU, etc.MeCan Medical Best Quality In Stock Invasive ICU Ventilators with Compressor ICU Respirator Factory,MeCan provide one-stop solutions for new hospitals,clinics,labs and universities,has helped 270 hospitals,540 clinics,190 vet clinics to set up in Malaysia,Africa,Europe,etc.we can save your time,energy and money.

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
  • MCS0151

  • MeCan

Medical Ventilator ICU Ventilators

Model:MCS0151
AV-2000B3-1
Display Mode: 10.4 inch High-denfinition TFT color LCD screen display
VentilationMode: VCV,PCV,SIMV,PSV,PSV+SIMV,CPAP
Ventilation Function: PEEP,SIGH, IRV, IP,Standby

Ventilation Parameter:

Tidal volume 20~1800 ml
Rate 2~120bpm
SIMV rate 2~120bpm
I:E 4:1~1:8
Pressure trigger sensitivity -10-20cmH2O
Flow trigger sensitivity 1-20L/min
PEEP 0~25 cmH2O
Pressure range 3~50 cmH2O
Pressure limitation 5~60 cmH2O
Pressure slope 1~10 gear
Flow rate setting 1~10 gear
Expiratory trigger sensitivity 10%-90%
Time control 1~10s
SIGH 1.5 times the inspiratory time (60-120 adjustable)
Inspiratory platform 0~50%
Oxygen concentration 21%~100%


Parameters for ventilation monitoring:
Expired tidal volume, Inhale tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous inspiratory rate, I/E, peak pressure of airway, average pressure, PEEP, inspiratory trigger pressure, Inspiratory platform, oxygen concentration, battery capacity, pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure-volume loop

Security Alarm System:

Oxygen concentration Upper limit setting range 21%-99%
Low limit setting range 15%-80%
Airway pressure alarm Upper limit setting range 1-60cmH2O
Low limit setting range 0-50cmH2O
Minute ventilation volume alarm Upper limit setting range 1-30L/min
Low limit setting range 0-29L/min
Tidal volume Upper limit setting range 10-2000ml
Low limit setting range 0-1800ml
Respiratory rate Upper limit setting range 10-99bpm
Low limit setting range 0-50bpm
Sustained high-pressure alarm It will give alarm when stress have consistently been higher than 30 cnH2O
Suffocation alarm Low pressure of Air alarm
Gas shortage alarm Power alarm; Intubation off alarm
Low pressure of Oxygen alarm Battery voltage alarm



Production line of our ventilator


Production line of our ventilator  Production line of our ventilator

Previous: 
Next: