MCS0151 is professional for COVID-19 treatment, can be used in respiratory management of after anesthesia operation, ambulance room, ICU, etc.MeCan Medical Best Quality In Stock Invasive ICU Ventilators with Compressor ICU Respirator Factory,MeCan provide one-stop solutions for new hospitals,clinics,labs and universities,has helped 270 hospitals,540 clinics,190 vet clinics to set up in Malaysia,Africa,Europe,etc.we can save your time,energy and money.
Availability: | |
---|---|
Quantity: | |
MCS0151
MeCan
Tidal volume | 20~1800 ml |
Rate | 2~120bpm |
SIMV rate | 2~120bpm |
I:E | 4:1~1:8 |
Pressure trigger sensitivity | -10-20cmH2O |
Flow trigger sensitivity | 1-20L/min |
PEEP | 0~25 cmH2O |
Pressure range | 3~50 cmH2O |
Pressure limitation | 5~60 cmH2O |
Pressure slope | 1~10 gear |
Flow rate setting | 1~10 gear |
Expiratory trigger sensitivity | 10%-90% |
Time control | 1~10s |
SIGH | 1.5 times the inspiratory time (60-120 adjustable) |
Inspiratory platform | 0~50% |
Oxygen concentration | 21%~100% |
Parameters for ventilation monitoring:
Expired tidal volume, Inhale tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous inspiratory rate, I/E, peak pressure of airway, average pressure, PEEP, inspiratory trigger pressure, Inspiratory platform, oxygen concentration, battery capacity, pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure-volume loop
Security Alarm System:
Oxygen concentration | Upper limit setting range | 21%-99% |
Low limit setting range | 15%-80% | |
Airway pressure alarm | Upper limit setting range | 1-60cmH2O |
Low limit setting range | 0-50cmH2O | |
Minute ventilation volume alarm | Upper limit setting range | 1-30L/min |
Low limit setting range | 0-29L/min | |
Tidal volume | Upper limit setting range | 10-2000ml |
Low limit setting range | 0-1800ml | |
Respiratory rate | Upper limit setting range | 10-99bpm |
Low limit setting range | 0-50bpm | |
Sustained high-pressure alarm | It will give alarm when stress have consistently been higher than 30 cnH2O | |
Suffocation alarm | Low pressure of Air alarm | |
Gas shortage alarm | Power alarm; Intubation off alarm | |
Low pressure of Oxygen alarm | Battery voltage alarm |
Production line of our ventilator
Tidal volume | 20~1800 ml |
Rate | 2~120bpm |
SIMV rate | 2~120bpm |
I:E | 4:1~1:8 |
Pressure trigger sensitivity | -10-20cmH2O |
Flow trigger sensitivity | 1-20L/min |
PEEP | 0~25 cmH2O |
Pressure range | 3~50 cmH2O |
Pressure limitation | 5~60 cmH2O |
Pressure slope | 1~10 gear |
Flow rate setting | 1~10 gear |
Expiratory trigger sensitivity | 10%-90% |
Time control | 1~10s |
SIGH | 1.5 times the inspiratory time (60-120 adjustable) |
Inspiratory platform | 0~50% |
Oxygen concentration | 21%~100% |
Parameters for ventilation monitoring:
Expired tidal volume, Inhale tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous inspiratory rate, I/E, peak pressure of airway, average pressure, PEEP, inspiratory trigger pressure, Inspiratory platform, oxygen concentration, battery capacity, pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure-volume loop
Security Alarm System:
Oxygen concentration | Upper limit setting range | 21%-99% |
Low limit setting range | 15%-80% | |
Airway pressure alarm | Upper limit setting range | 1-60cmH2O |
Low limit setting range | 0-50cmH2O | |
Minute ventilation volume alarm | Upper limit setting range | 1-30L/min |
Low limit setting range | 0-29L/min | |
Tidal volume | Upper limit setting range | 10-2000ml |
Low limit setting range | 0-1800ml | |
Respiratory rate | Upper limit setting range | 10-99bpm |
Low limit setting range | 0-50bpm | |
Sustained high-pressure alarm | It will give alarm when stress have consistently been higher than 30 cnH2O | |
Suffocation alarm | Low pressure of Air alarm | |
Gas shortage alarm | Power alarm; Intubation off alarm | |
Low pressure of Oxygen alarm | Battery voltage alarm |
Production line of our ventilator